YY
Yu Yuan
Author with expertise in Optogenetics in Neuroscience and Biophysics Research
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
4
(100% Open Access)
Cited by:
0
h-index:
2
/
i10-index:
0
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Two-photon imaging of excitatory and inhibitory neural response to infrared neural stimulation

Peng Fu et al.Mar 3, 2024
+9
M
Y
P
Abstract Significance Pulsed infrared neural stimulation (INS, 1875 nm) is an emerging neurostimulation technology that delivers focal pulsed heat to activate functionally specific mesoscale networks and holds promise for clinical application. However, little is known about its effect on excitatory and inhibitory cell types in cerebral cortex. Aim Estimates of summed population neuronal response timecourses provide a potential basis for neural and hemodynamic signals described in other studies. Approach Using two-photon calcium imaging in mouse somatosensory cortex, we have examined the effect of INS pulse train application on hSyn neurons and mDlx neurons tagged with GCaMP6s. Results We find that, in anesthetized mice, each INS pulse train reliably induces robust response in hSyn neurons exhibiting positive going responses. Surprisingly, mDlx neurons exhibit negative going responses. Quantification using the index of correlation illustrates responses are reproducible, intensity-dependent, and distance-dependent. Also, a contralateral activation is observed when INS application. Conclusions In sum, the population of neurons stimulated by INS includes both hSyn and mDlx neurons; within a range of stimulation intensities, this leads to overall excitation in the stimulated population, leading to the previously observed activations at distant post-synaptic sites.
0

Analytical performance evaluation of hemoglobin A1c on an ARKRAY HA-8160 analyzer with newly-developed mobile phase buffer

Yu Yuan et al.May 1, 2024
K
X
Y
Most glycated hemoglobin A1c (HbA1c) analytical reagents used were obtained from the analyzer's manufacturer. However, clinical laboratories need more choices for HbA1c analytical reagents to overcome the limitations of dedicated reagents for special analyzers. We developed new mobile phase buffers as HbA1c diagnostic reagents and evaluated their analytical performance for the HbA1c assay. Different mobile phase buffers used as HbA1c diagnostic reagents were prepared using different concentrations of sodium salts. According to the Clinical and Laboratory Standards Institute (CLSI) recommendation guidelines, the analytical performances of the newly developed mobile phase buffers were evaluated on an ARKRAY HA-8160 Analyzer. Both quality controls and clinical blood samples were used in these experiments. To assess the quality of the newly developed mobile phase buffers, precision, accuracy, linearity, carryover, interference, bias, correlation with commercial reagents, and stability were analyzed. The CVs of intra-assay precision and interassay precision of quality control and clinical There were fewer than 1.00% blood sample assays using the newly developed mobile phase buffer. The RDs of accuracy were less than 1.00%. Linearity: R2=0.9998 in the concentration range of 4.40%-17.30%. Carryover: 0.00%. Reagent comparison revealed that the Pearson regression equation was Y=0.9884x+0.05692 (R2=0.9977), and the Bland-Altman mean difference was -0.02650% (CI: -0.2121% to 0.1591%) between the two analytical reagents. Stability was also acceptable within 12 months. This mobile phase buffer showed good anti-interference ability. The newly developed mobile phase buffers demonstrated good analytical performance and were suitable for clinical HbA1c assays on an ARKRAY HA-8160 Analyzer.
0

Projection neurons from medial entorhinal cortex to basolateral amygdala are critical for the retrieval of morphine withdrawal memory

Yali Fu et al.Jul 1, 2024
+14
T
Z
Y
The medial entorhinal cortex (MEC) is crucial for contextual memory, yet its role in context-induced retrieval of morphine withdrawal memory remains unclear. This study investigated the role of the MEC and its projection neurons from MEC layer 5 to the basolateral amygdala (BLA) (MEC
0

Two-photon imaging of excitatory and inhibitory neural response to infrared neural stimulation

Peng Fu et al.May 24, 2024
+8
L
Y
P
SignificancePulsed infrared neural stimulation (INS, 1875 nm) is an emerging neurostimulation technology that delivers focal pulsed heat to activate functionally specific mesoscale networks and holds promise for clinical application. However, little is known about its effect on excitatory and inhibitory cell types in cerebral cortex.AimEstimates of summed population neuronal response time courses provide a potential basis for neural and hemodynamic signals described in other studies.ApproachUsing two-photon calcium imaging in mouse somatosensory cortex, we have examined the effect of INS pulse train application on hSyn neurons and mDlx neurons tagged with GCaMP6s.ResultsWe find that, in anesthetized mice, each INS pulse train reliably induces robust response in hSyn neurons exhibiting positive going responses. Surprisingly, mDlx neurons exhibit negative going responses. Quantification using the index of correlation illustrates responses are reproducible, intensity-dependent, and focal. Also, a contralateral activation is observed when INS applied.ConclusionsIn sum, the population of neurons stimulated by INS includes both hSyn and mDlx neurons; within a range of stimulation intensities, this leads to overall excitation in the stimulated population, leading to the previously observed activations at distant post-synaptic sites.