JW
Jannie Wijnen
Author with expertise in Magnetic Resonance Imaging Applications in Medicine
Achievements
This user has not unlocked any achievements yet.
Key Stats
Upvotes received:
0
Publications:
8
(13% Open Access)
Cited by:
0
h-index:
24
/
i10-index:
46
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
4

Lipid suppressed and tissue-fraction corrected metabolic distributions in human central brain structures using 2D 1H Magnetic Resonance Spectroscopic Imaging at 7 tesla

Alex Bhogal et al.Jun 11, 2020
ABSTRACT Magnetic resonance spectroscopic imaging (MRSI) has the potential to add a layer of understanding of the neurobiological mechanisms underlying brain diseases, disease progression, and treatment efficacy. Limitations related to metabolite fitting of low SNR data, signal variations due to partial volume effects, acquisition and extra-cranial lipid artefacts, along with clinically relevant aspects such as scan-time constraints, are among the factors that hinder the widespread implementation of in vivo MRSI. The aim of this work was to address these factors and to develop an acquisition, reconstruction and post-processing pipeline to derive lipid suppressed metabolite values based on Free Induction Decay (FID-MRSI) measurements made using a 7 tesla MR scanner. Anatomical images were used to perform high-resolution (1mm 3 ) partial-volume correction to account for grey matter, white matter and cerebral-spinal fluid signal contributions. Implementation of automatic quality control thresholds and normalization of metabolic maps from 23 subjects to the MNI standard atlas facilitated the creation of high-resolution average metabolite maps of several clinically relevant metabolites in central brain regions, while accounting for macromolecular distributions. Reported metabolite values include glutamate, choline, (phospo)creatine, myo-inositol, glutathione, N-acetyl aspartyl glutamate(and glutamine) and N-acetyl aspartate. MNI-registered average metabolite maps facilitate group-based analysis; thus offering the possibility to mitigate uncertainty in variable MRSI.
0

Enhancing 2D MRSI: Implementation of CHEmical-shift Adiabatic Pulses (CHEAP) at a 7T Philips platform using Pulseq

Kyung Nam et al.Nov 26, 2024
Motivation: Nuisance signal contamination and challenges associated with implementation involving advanced RF pulses and sequence hinder clinical adoption. Simplified sequence implementation and dissemination are crucial for community-driven advancement and vendor support. Goal(s): Our goal is to integrate CHEmical-shift selective Adiabatic refocusing Pulses(CHEAP) on the Philips platform via Pulseq open-source platform, creating advanced MRSI sequences that refine metabolite analysis by minimizing unwanted signals. Approach: Integrating chemically selective adiabatic 2-refocus pulses in Pulseq achieved optimal spectrum coverage, reducing interference from residual water and lipid signals. Results: Implementing the CHEAP sequence significantly mitigated interference from residual water and lipid signals, demonstrating its potential for advancing MRSI. Impact: The implementation of CHEAP sequence via Pulseq promises a standardized, shareable method, fostering collaboration and enabling precise metabolic studies. This advancement in MRS techniques may significantly improve reproducibility across sites and enhance capacity for metabolic profiling in health and disease.