MH
Matt Hall
Author with expertise in Diffusion Magnetic Resonance Imaging
University College London, National Physical Laboratory, Agile Scientific (Canada)
+ 7 more
Achievements
Open Access Advocate
Cited Author
Key Stats
Upvotes received:
0
Publications:
4
(100% Open Access)
Cited by:
56
h-index:
23
/
i10-index:
36
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
1

In vivo demonstration of microscopic anisotropy in the human kidney using multidimensional diffusion MRI

Fábio Nery et al.Nov 23, 2023
+5
L
F
F
Purpose To demonstrate the feasibility of multidimensional diffusion MRI to probe and quantify microscopic fractional anisotropy (µFA) in human kidneys in vivo. Methods Linear tensor encoded (LTE) and spherical tensor encoded (STE) renal diffusion MRI scans were performed in 10 healthy volunteers. Respiratory triggering and image registration were used to minimize motion artefacts during the acquisition. Kidney cortex–medulla were semi‐automatically segmented based on fractional anisotropy (FA) values. A model‐free analysis of LTE and STE signal dependence on b‐value in the renal cortex and medulla was performed. Subsequently, µFA was estimated using a single‐shell approach. Finally, a comparison of conventional FA and µFA is shown. Results The hallmark effect of µFA (divergence of LTE and STE signal with increasing b‐value) was observed in all subjects. A statistically significant difference between LTE and STE signal was found in the cortex and medulla, starting from b = 750 s/mm 2 and b = 500 s/mm 2 , respectively. This difference was maximal at the highest b‐value sampled ( b = 1000 s/mm 2 ) which suggests that relatively high b‐values are required for µFA mapping in the kidney compared to conventional FA. Cortical and medullary µFA were, respectively, 0.53 ± 0.09 and 0.65 ± 0.05, both respectively higher than conventional FA (0.19 ± 0.02 and 0.40 ± 0.02). Conclusion The feasibility of combining LTE and STE diffusion MRI to probe and quantify µFA in human kidneys is demonstrated for the first time. By doing so, we show that novel microstructure information—not accessible by conventional diffusion encoding—can be probed by multidimensional diffusion MRI. We also identify relevant technical limitations that warrant further development of the technique for body MRI.
1

Validation and noise robustness assessment of microscopic anisotropy estimation with clinically feasible double diffusion encoding MRI

Leevi Kerkelä et al.Nov 23, 2023
+2
M
R
L
Purpose Double diffusion encoding (DDE) MRI enables the estimation of microscopic diffusion anisotropy, yielding valuable information on tissue microstructure. A recent study proposed that the acquisition of rotationally invariant DDE metrics, typically obtained using a spherical “5‐design,” could be greatly simplified by assuming Gaussian diffusion, facilitating reduced acquisition times that are more compatible with clinical settings. Here, we aim to validate the new minimal acquisition scheme against the standard DDE 5‐design, and to quantify the proposed method's noise robustness to facilitate future clinical use. Theory and Methods DDE MRI experiments were performed on both ex vivo and in vivo rat brains at 9.4 T using the 5‐design and the proposed minimal design and taking into account the difference in the number of acquisitions. The ensuing microscopic fractional anisotropy (μFA) maps were compared over a range of b ‐values up to 5000 s/mm 2 . Noise robustness was studied using analytical calculations and numerical simulations. Results The minimal protocol quantified μFA at an accuracy comparable to the estimates obtained by means of the more theoretically robust DDE 5‐design. μFA's sensitivity to noise was found to strongly depend on compartment anisotropy and tensor magnitude in a nonlinear manner. When μFA < 0.75 or when mean diffusivity is particularly low, very high signal‐to‐noise ratio is required for precise quantification of µFA. Conclusion Our work supports using DDE for quantifying microscopic diffusion anisotropy in clinical settings but raises hitherto overlooked precision issues when measuring μFA with DDE and typical clinical signal‐to‐noise ratio.
1
Citation14
0
Save
12

Disimpy: A massively parallel Monte Carlo simulator for generating diffusion-weighted MRI data in Python

Leevi Kerkelä et al.Jun 19, 2023
C
M
F
L
Disimpy is a simulator for generating diffusion-weighted magnetic resonance imaging (dMRI) data that is useful in the development and validation of new methods for data acquisition and analysis.Diffusion of water is modelled as an ensemble of random walkers whose trajectories are generated on an Nvidia (Nvidia Corporation, Santa Clara, California, United States) CUDA-capable (Nickolls, Buck, Garland, & Skadron, 2008) graphical processing unit (GPU).The massive parallelization results in a significant performance gain, enabling simulation experiments to be performed on standard laptop and desktop computers.Disimpy is written in Python (Python Software Foundation), making its source code very approachable and easily extensible.
2

Comparative analysis of signal models for microscopic fractional anisotropy estimation using q-space trajectory encoding

Leevi Kerkelä et al.Jun 28, 2023
+8
R
F
L
Microscopic diffusion anisotropy imaging using diffusion-weighted MRI and multidimensional diffusion encoding is a promising method for quantifying clinically and scientifically relevant microstructural properties of neural tissue. Several methods for estimating microscopic fractional anisotropy (µFA), a normalized measure of microscopic diffusion anisotropy, have been introduced but the differences between the methods have received little attention thus far. In this study, the accuracy and precision of µFA estimation using q-space trajectory encoding and different signal models were assessed using imaging experiments and simulations. Three healthy volunteers and a microfibre phantom were imaged with five non-zero b-values and gradient waveforms encoding linear and spherical b-tensors. Since the ground-truth µFA was unknown in the imaging experiments, Monte Carlo random walk simulations were performed using axon-mimicking fibres for which the ground truth was known. Furthermore, parameter bias due to time-dependent diffusion was quantified by repeating the simulations with tuned waveforms, which have similar power spectra, and with triple diffusion encoding, which, unlike q-space trajectory encoding, is not based on the assumption of time-independent diffusion. The truncated cumulant expansion of the powder-averaged signal, gamma-distributed diffusivities assumption, and q-space trajectory imaging, a generalization of the truncated cumulant expansion to individual signals, were used to estimate µFA. The gamma-distributed diffusivities assumption consistently resulted in greater µFA values than the second order cumulant expansion, 0.1 greater when averaged over the whole brain. In the simulations, the generalized cumulant expansion provided the most accurate estimates. Importantly, although time-dependent diffusion caused significant overestimation of µFA using all the studied methods, the simulations suggest that the resulting bias in µFA is less than 0.1 in human white matter.
2
Citation7
1
Save