OK
Olaf Klungel
Author with expertise in Management and Pathophysiology of Traumatic Brain Injury
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
5
(100% Open Access)
Cited by:
1,290
h-index:
58
/
i10-index:
249
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Estimating measures of interaction on an additive scale for preventive exposures

Mirjam Knol et al.Feb 22, 2011
Measures of interaction on an additive scale (relative excess risk due to interaction [RERI], attributable proportion [AP], synergy index [S]), were developed for risk factors rather than preventive factors. It has been suggested that preventive factors should be recoded to risk factors before calculating these measures. We aimed to show that these measures are problematic with preventive factors prior to recoding, and to clarify the recoding method to be used to circumvent these problems. Recoding of preventive factors should be done such that the stratum with the lowest risk becomes the reference category when both factors are considered jointly (rather than one at a time). We used data from a case-control study on the interaction between ACE inhibitors and the ACE gene on incident diabetes. Use of ACE inhibitors was a preventive factor and DD ACE genotype was a risk factor. Before recoding, the RERI, AP and S showed inconsistent results (RERI = 0.26 [95%CI: −0.30; 0.82], AP = 0.30 [95%CI: −0.28; 0.88], S = 0.35 [95%CI: 0.02; 7.38]), with the first two measures suggesting positive interaction and the third negative interaction. After recoding the use of ACE inhibitors, they showed consistent results (RERI = −0.37 [95%CI: −1.23; 0.49], AP = −0.29 [95%CI: −0.98; 0.40], S = 0.43 [95%CI: 0.07; 2.60]), all indicating negative interaction. Preventive factors should not be used to calculate measures of interaction on an additive scale without recoding.
0
Citation533
0
Save
0

Instrumental Variables

Edwin Martens et al.Apr 13, 2006
To correct for confounding, the method of instrumental variables (IV) has been proposed. Its use in medical literature is still rather limited because of unfamiliarity or inapplicability. By introducing the method in a nontechnical way, we show that IV in a linear model is quite easy to understand and easy to apply once an appropriate instrumental variable has been identified. We also point out some limitations of the IV estimator when the instrumental variable is only weakly correlated with the exposure. The IV estimator will be imprecise (large standard error), biased when sample size is small, and biased in large samples when one of the assumptions is only slightly violated. For these reasons, it is advised to use an IV that is strongly correlated with exposure. However, we further show that under the assumptions required for the validity of the method, this correlation between IV and exposure is limited. Its maximum is low when confounding is strong, such as in case of confounding by indication. Finally, we show that in a study in which strong confounding is to be expected and an IV has been used that is moderately or strongly related to exposure, it is likely that the assumptions of IV are violated, resulting in a biased effect estimate. We conclude that instrumental variables can be useful in case of moderate confounding but are less useful when strong confounding exists, because strong instruments cannot be found and assumptions will be easily violated.
0

The reporting of studies conducted using observational routinely collected health data statement for pharmacoepidemiology (RECORD-PE)

Sinéad Langan et al.Nov 14, 2018
In pharmacoepidemiology, routinely collected data from electronic health records (including primary care databases, registries, and administrative healthcare claims) are a resource for research evaluating the real world effectiveness and safety of medicines. Currently available guidelines for the reporting of research using non-randomised, routinely collected data—specifically the REporting of studies Conducted using Observational Routinely collected health Data (RECORD) and the Strengthening the Reporting of OBservational studies in Epidemiology (STROBE) statements—do not capture the complexity of pharmacoepidemiological research. We have therefore extended the RECORD statement to include reporting guidelines specific to pharmacoepidemiological research (RECORD-PE). This article includes the RECORD-PE checklist (also available on www.record-statement.org) and explains each checklist item with examples of good reporting. We anticipate that increasing use of the RECORD-PE guidelines by researchers and endorsement and adherence by journal editors will improve the standards of reporting of pharmacoepidemiological research undertaken using routinely collected data. This improved transparency will benefit the research community, patient care, and ultimately improve public health.
0

Applying two approaches to detect unmeasured confounding due to time-varying variables in a self-controlled risk interval design evaluating COVID-19 vaccine safety signals, using myocarditis as a case example

Sophie Bots et al.Jul 3, 2024
Abstract We test the robustness of the self-controlled risk interval (SCRI) design in a setting where time between doses may introduce time-varying confounding, using both negative control outcomes (NCOs) and quantitative bias analysis (QBA). All vaccinated cases identified from 5 European databases between 1 September 2020 and end of data availability were included. Exposures were doses 1-3 of the Pfizer, Moderna, AstraZeneca, and Janssen COVID-19 vaccines; outcomes were myocarditis and otitis externa (NCO). The SCRI used a 60-day control window and dose-specific 28-day risk windows, stratified by vaccine brand and adjusted for calendar time. The QBA included two scenarios: (i) baseline probability of the confounder was higher in the control window and (ii) vice versa. The NCO was not associated with any of the COVID-19 vaccine types or doses except Moderna dose 1 (IRR = 1.09, 95%CI 1.01-1.09). The QBA suggested even the strongest literature-reported confounder (COVID-19; RRmyocarditis = 18.3) could only explain away part of the observed effect from IRR = 3 to IRR = 1.40. The SCRI seems robust to unmeasured confounding in the COVID-19 setting, although a strong unmeasured confounder could bias the observed effect upward. Replication of our findings for other safety signals would strengthen this conclusion.