JK
Jaffar Khan
Author with expertise in Management of Valvular Heart Disease
Achievements
Cited Author
Key Stats
Upvotes received:
0
Publications:
6
(33% Open Access)
Cited by:
208
h-index:
32
/
i10-index:
71
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Native Valve and Native Neo-Sinus Remodeling Following Transcatheter Aortic Valve Replacement

J.S. Yoon et al.Dec 1, 2024
BACKGROUND: Transcatheter aortic valve replacement (TAVR) pushes aside the diseased native aortic valve and creates a native neo-sinus bordered by the aortic root wall and the displaced native valve. There are limited data on the progression of native valve disease post-TAVR and no previous analysis of the native neo-sinus. METHODS: Native aortic valves and native neo-sinus explants obtained post-TAVR were evaluated histologically (hematoxylin and eosin, Movat pentachrome, and Martius Scarlet Blue stains) and by immunohistochemistry (TGF-β1 [transforming growth factor-beta 1], FAP [fibroblast activation protein], and ALP [alkaline phosphatase]) to assess disease mechanisms. RESULTS: Native aortic valves were obtained from 20 patients from 0 to 2583 days (7.08 years) post-TAVR. Native leaflets showed persistent calcific aortic stenosis-like disease activity with positivity for ALP and FAP. Native valve remodeling was observed as changes in architecture evident in explants >1.5 years, which was observed as crumpling of the leaflets. Disease activity was also present in native neo-sinuses with transcatheter heart valve implant durations >1 year with positive staining for TGF-β1, FAP, and ALP. Extensive native neo-sinus remodeling occurred with replacement and filling-in of this space with contiguous extracellular matrix, calcific deposits, and microvessels. CONCLUSIONS: Following TAVR, there is ongoing calcific aortic stenosis-like disease with architectural changes to native leaflets and extensive remodeling of the native neo-sinus, evidenced by replacement and contiguous filling-in of the native neo-sinus blood pool space with increasing implant duration. The dynamic nature of these tissues has potential implications for neo-sinus flow, valve degeneration, and re-intervention.
0
Citation1
0
Save
0

Ventricular Intramyocardial Navigation for Tachycardia Ablation Guided by Electrograms (VINTAGE)

Rim Halaby et al.May 1, 2024
Deep intramural ventricular tachycardia substrate targets are difficult to access, map, and ablate from endocardial and epicardial surfaces, resulting in high recurrence rates. In this study, the authors introduce a novel approach called ventricular intramyocardial navigation for tachycardia ablation guided by electrograms (VINTAGE) to access and ablate anatomically challenging ventricular tachycardia from within the myocardium. Guidewire/microcatheter combinations were navigated deep throughout the extravascular myocardium, accessed directly from the right ventricle cavity, in Yorkshire swine (6 naive, 1 infarcted). Devices were steered to various intramyocardial targets including the left ventricle summit, guided by fluoroscopy, unipolar electrograms, and/or electroanatomic mapping. Radiofrequency ablations were performed to characterize ablation parameters and reproducibility. Intramyocardial saline irrigation began 1 minute before ablation and continued throughout. Lesions were analyzed on cardiac magnetic resonance and necropsy. VINTAGE was feasible in all animals within naive and infarcted myocardium. Forty-three lesions were created, using various guidewires and power settings. Forty-one (95%) lesions were detected on cardiac magnetic resonance and 38 (88%) on necropsy; all undetected lesions resulted from intentionally subtherapeutic ablation energy (10 W). Larger-diameter guidewires yielded larger size lesions. Lesion volumes on necropsy were significantly larger at 20 W than 10 W (178 mm3 [Q1-Q3: 104-382 mm3] vs 49 mm3 [Q1-Q3: 35-93 mm3]; P = 0.02). Higher power (30 W) did not create larger lesions. Median impedance dropped with preablation irrigation by 12 Ω (Q1-Q3: 8-17 Ω), followed by a further 15-Ω (Q1-Q3: 11-19 Ω) drop during ablation. Intramyocardial navigation, ablation, and irrigation were not associated with any complications. VINTAGE was safe and effective at creating intramural ablation lesions in targets traditionally considered inaccessible from the endocardium and epicardium, both naive and infarcted. Intramyocardial guidewire irrigation and ablation at 20 W creates reproducibly large intramural lesions.