CM
C. Mattsson
Author with expertise in Effects of Physical Activity on Health Outcomes
Achievements
Open Access Advocate
Cited Author
Key Stats
Upvotes received:
0
Publications:
5
(80% Open Access)
Cited by:
531
h-index:
24
/
i10-index:
35
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
1

Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort

Anna Shcherbina et al.May 24, 2017
+5
D
C
A
The ability to measure physical activity through wrist-worn devices provides an opportunity for cardiovascular medicine. However, the accuracy of commercial devices is largely unknown. The aim of this work is to assess the accuracy of seven commercially available wrist-worn devices in estimating heart rate (HR) and energy expenditure (EE) and to propose a wearable sensor evaluation framework. We evaluated the Apple Watch, Basis Peak, Fitbit Surge, Microsoft Band, Mio Alpha 2, PulseOn, and Samsung Gear S2. Participants wore devices while being simultaneously assessed with continuous telemetry and indirect calorimetry while sitting, walking, running, and cycling. Sixty volunteers (29 male, 31 female, age 38 ± 11 years) of diverse age, height, weight, skin tone, and fitness level were selected. Error in HR and EE was computed for each subject/device/activity combination. Devices reported the lowest error for cycling and the highest for walking. Device error was higher for males, greater body mass index, darker skin tone, and walking. Six of the devices achieved a median error for HR below 5% during cycling. No device achieved an error in EE below 20 percent. The Apple Watch achieved the lowest overall error in both HR and EE, while the Samsung Gear S2 reported the highest. In conclusion, most wrist-worn devices adequately measure HR in laboratory-based activities, but poorly estimate EE, suggesting caution in the use of EE measurements as part of health improvement programs. We propose reference standards for the validation of consumer health devices (http://precision.stanford.edu/).
1
Paper
Citation508
0
Save
0

Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort

Anna Shcherbina et al.Dec 17, 2016
+5
D
C
A
Abstract Background The ability to measure activity and physiology through wrist-worn devices provides an opportunity for cardiovascular medicine. However, the accuracy of commercial devices is largely unknown. Objective To assess the accuracy of seven commercially available wrist-worn devices in estimating heart rate (HR) and energy expenditure (EE) and to propose a wearable sensor evaluation framework. Methods We evaluated the Apple Watch, Basis Peak, Fitbit Surge, Microsoft Band, Mio Alpha 2, PulseOn, and Samsung Gear S2. Participants wore devices while being simultaneously assessed with continuous telemetry and indirect calorimetry while sitting, walking, running, and cycling. Sixty volunteers (29 male, 31 female, age 38 ± 11 years) of diverse age, height, weight, skin tone, and fitness level were selected. Error in HR and EE was computed for each subject/device/activity combination. Results Devices reported the lowest error for cycling and the highest for walking. Device error was higher for males,greater body mass index, darker skin tone, and walking. Six of the devices achieved a median error for HR below 5% during cycling. No device achieved an error in EE below 20 percent. The Apple Watch achieved the lowest overall error in both HR and EE, while the Samsung Gear S2 reported the highest. Conclusions Most wrist-worn devices adequately measure HR in laboratory-based activities, but poorly estimate EE, suggesting caution in the use of EE measurements as part of health improvement programs. We propose reference standards for the validation of consumer health devices ( http://precision.stanford.edu/ ). Abbreviations (EE) Energy expenditure (HR) Heart rate (GEE) General estimating equation
0
Paper
Citation20
0
Save
1

An equine Endothelin 3 cis-regulatory variant links blood pressure modulation to elite racing performance

Kim Fegraeus et al.Nov 4, 2022
+11
R
M
K
Abstract A previous selective sweep analysis of horse racing performance revealed a 19.6 kb candidate region approximately 50 kb downstream of the Endothelin 3 ( EDN3 ) gene. EDN3 and other endothelin family members are associated with blood pressure regulation in humans and other species, but similar association studies in horses are lacking. We hypothesized that the sweep region includes a regulatory element acting on EDN3 transcription, ultimately affecting blood pressure regulation and athletic performance in horses. Selective sweep fine- mapping identified a 5.5 kb haplotype of 14 SNPs shared within Coldblooded trotters (CBT) and Standardbreds (SB). Most SNPs overlapped potential transcription factor binding sites, and haplotype analysis showed significant association with all tested performance traits in CBTs and earnings in SBs. From those, two haplotypes were defined: an elite performing haplotype (EPH) and a sub-elite performing haplotype (SPH). While the majority of SNPs in the haplotype were part of the standing variation already found in pre-domestication horses, there has been an increase in the frequencies of the alternative alleles during the whole history of horse domestication. Horses homozygous for EPH had significantly higher plasma levels of EDN3, lower levels of EDN1, and lower exercise-related blood pressure compared to SPH homozygous horses. Additionally, a global proteomic analysis of plasma from EPH or SPH homozygous horses revealed higher levels of proteins involved in pathways related to immune response and complement activation in the SPH horses. This is the first study to demonstrate an association between the EDN3 gene, blood pressure regulation, and athletic performance in horses. The results advance our understanding of the molecular genetics of athletic performance, exercise-related blood pressure regulation, and biological processes activated by intense exercise. Author summary The horse is one of the most common species used for studying athletic performance. For centuries, horses have been used by humans for transportation, agriculture and entertainment and this has resulted in selection for various traits related to athletic performance. A previous study discovered that a genetic region close to the Endothelin3 gene was associated with harness racing performance. Endothelin3 is known to be involved in blood pressure regulation and therefore we hypothesized that this region influences blood pressure and racing performance in horses. In this study we have used additional horses and fine-mapped the candidate region and we also measured blood pressure in Coldblooded trotters during exercise. Horses with two copies of the elite-performing haplotype had higher levels of Endothelin3 in plasma, lower blood pressure and better racing performance results, compared to horses with two copies of the sub-elite performing haplotype. We also discovered that horses with the sub-elite performing haplotype had higher levels of proteins related to the immune system in plasma. This study is the first to link Endothelin3 to blood pressure regulation and performance in horses. It broadens the understanding of the biological mechanisms behind blood pressure regulation as well as inflammation and coagulation system in relation to racing performance.
1
Citation2
0
Save
0

An endothelial regulatory module links blood pressure regulation with elite athletic performance

Kim Fegraeus et al.Jun 17, 2024
+16
R
M
K
The control of transcription is crucial for homeostasis in mammals. A previous selective sweep analysis of horse racing performance revealed a 19.6 kb candidate regulatory region 50 kb downstream of the Endothelin3 ( EDN3 ) gene. Here, the region was narrowed to a 5.5 kb span of 14 SNVs, with elite and sub-elite haplotypes analyzed for association to racing performance, blood pressure and plasma levels of EDN3 in Coldblooded trotters and Standardbreds. Comparative analysis of human HiCap data identified the span as an enhancer cluster active in endothelial cells, interacting with genes relevant to blood pressure regulation. Coldblooded trotters with the sub-elite haplotype had significantly higher blood pressure compared to horses with the elite performing haplotype during exercise. Alleles within the elite haplotype were part of the standing variation in pre-domestication horses, and have risen in frequency during the era of breed development and selection. These results advance our understanding of the molecular genetics of athletic performance and vascular traits in both horses and humans.
0
Citation1
0
Save
0

Physiological factors of importance for load carriage

Manne Godhe et al.Jun 30, 2017
+4
C
T
M
The energy expenditure during carrying no load, 20, 35 and 50 kg at two walking speeds, 3 and 5 km/h, was studied in 36 healthy participants, 19 men (30 ± 6 yrs, 82.5 ± 7.0 kg) and 17 women (29 ± 6 yrs, 66.1 ± 8.9 kg). Anthropometric data, leg muscle strength as well as trunk muscle endurance and muscle fibre distribution of the thigh were also obtained. To load the participant a standard backpack filled with extra weight according to the carrying weight tested was used. Extra Load Index (ELI), the oxygen uptake (VO2) during total load over no-load-exercise, was used as a proxy for load carrying ability. In addition to analyzing factors of importance for the ELI values, we also conducted mediator analyzes using sex and long term carrying experience as causal variables for ELI as the outcome value. For the lowest load (20 kg), ELI20, was correlated with body mass but no other factors. Walking at 5 km/h body mass, body height, leg muscle strength and absolute VO2max were correlated to ELI35 and ELI50, but relative VO2max, trunk muscle endurance and leg muscle fibre distribution were not. Sex as causal factor was evaluated in a mediator analyses with ELI50 as outcome. ELI50 at 5 km/h differed between the sexes. The limit for acceptable body load, 40% of VO2max (according to Astrand, 1967), was nearly reached for women carrying 35 kg (39%) and surpassed at 50 kg at 3 km/h, and for men carrying 50 kg at 5 km/h. This difference was only mediated by difference in body mass. Neither muscle fibre distribution, leg muscle strength, trunk muscle endurance and body height nor did absolute or relative VO2max explain the difference. Participants with long term experience of heavy load carrying had significant lower ELI20 and ELI50 values than those with minor or non-experience, but none of the above studied factors could explain this difference. The study showed that body mass and experience of carrying heavy loads are important factors for the ability to carry heavy loads.