NL
Nina LoGrande
Author with expertise in Vaginal Microbiome and Sexually Transmitted Infections
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
6
(100% Open Access)
Cited by:
9
h-index:
5
/
i10-index:
5
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
18

Vaginal microbiome-host interactions modeled in a human vagina-on-a-chip

Gautam Mahajan et al.Mar 21, 2022
+18
S
J
G
ABSTRACT Background A dominance of non-iners Lactobacillus species in the vaginal microbiome is optimal and strongly associated with gynecological and obstetric health, while the presence of diverse obligate or facultative anaerobic bacteria and a paucity in Lactobacillus species, similar to communities found in bacterial vaginosis (BV), is considered non-optimal and associated with adverse health outcomes. Various therapeutic strategies are being explored to modulate the composition of the vaginal microbiome; however, there is no human model that faithfully reproduces the vaginal epithelial microenvironment for preclinical validation of potential therapeutics or testing hypotheses about vaginal epithelium-microbiome interactions. Results Here, we describe an organ-on-a-chip (Organ Chip) microfluidic culture model of the human vaginal mucosa (Vagina Chip) that is lined by hormone-sensitive, primary vaginal epithelium interfaced with underlying stromal fibroblasts, which sustains a low physiological oxygen concentration in the epithelial lumen. We show that the Vagina Chip can be used to assess colonization by optimal L. crispatus consortia as well as non-optimal Gardnerella vaginalis -containing consortia, and to measure associated host innate immune responses. Co-culture of the L. crispatus consortia was accompanied by maintenance of epithelial cell viability, accumulation of D- and L-lactic acid, maintenance of a physiologically relevant low pH, and down regulation of proinflammatory cytokines. In contrast, co-culture of G. vaginalis- containing consortia in the Vagina Chip resulted in epithelial cell injury, a rise in pH, and upregulation of proinflammatory cytokines. Conclusion This study demonstrates the potential of applying human Organ Chip technology to create a preclinical model of the human vaginal mucosa that can be used to better understand interactions between the vaginal microbiome and host tissues, as well as to evaluate the safety and efficacy of live biotherapeutics products.
18
Citation4
0
Save
0

Mucus production, host-microbiome interactions, hormone sensitivity, and innate immune responses modeled in human cervix chips

Zohreh Izadifar et al.May 29, 2024
+14
S
J
Z
Abstract Modulation of the cervix by steroid hormones and commensal microbiome play a central role in the health of the female reproductive tract. Here we describe organ-on-a-chip (Organ Chip) models that recreate the human cervical epithelial-stromal interface with a functional epithelial barrier and production of mucus with biochemical and hormone-responsive properties similar to living cervix. When Cervix Chips are populated with optimal healthy versus dysbiotic microbial communities (dominated by Lactobacillus crispatus and Gardnerella vaginalis , respectively), significant differences in tissue innate immune responses, barrier function, cell viability, proteome, and mucus composition are observed that are similar to those seen in vivo. Thus, human Cervix Organ Chips represent physiologically relevant in vitro models to study cervix physiology and host-microbiome interactions, and hence may be used as a preclinical testbed for development of therapeutic interventions to enhance women’s health.
0
Citation3
0
Save
0

Mucus production, host-microbiome interactions, hormone sensitivity, and innate immune responses modeled in human cervix chips

Zohreh Izadifar et al.Feb 22, 2023
+17
S
J
Z
ABSTRACT Modulation of mucus production by the human endo– and ecto-cervical epithelium by steroid hormones and associated interactions with commensal microbiome play a central role in the physiology and pathophysiology of the female reproductive tract. However, most of our knowledge about these interactions is based on results from animal studies or in vitro models that fail to faithfully mimic the mucosal environment of the human cervix. Here we describe microfluidic organ-on-a-chip (Organ Chip) models of the human cervical mucosa that recreate the cervical epithelial-stromal interface with a functional epithelial barrier and produce abundant mucus that has compositional, biophysical, and hormone-responsive properties similar to the living cervix. Application of continuous fluid flow to chips lined with primary human cervical epithelial cells from a commercial source that contained a mixture of primary human ecto– and endo-cervical epithelial cells promoted preferential expression of the ecto-cervical phenotype, whereas use of periodic flow including periods of stasis induced endo-cervical specialization. When the periodic flow Cervix Chips were co-cultured with living Lactobacillus crispatus and Gardnerella vaginalis bacterial communities to respectively mimic the effects of human host interactions with optimal (healthy) or non-optimal (dysbiotic) microbiome associated with an ascending infection in the female reproductive tract, significant differences in tissue innate immune responses, barrier function, cell viability and protein profile, and mucus composition were detected reminiscent of those observed in vivo . Thus, these Organ Chip models of human cervix provide a physiologically relevant experimental in vitro model to study cervical mucus physiology and its role in human host-microbiome interactions as well as a potential preclinical testbed for development of therapeutic interventions to enhance women’s health.
0
Citation2
0
Save
0

Organ Chips with integrated multifunctional sensors enable continuous metabolic monitoring at controlled oxygen levels

Zohreh Izadifar et al.Aug 9, 2024
+11
M
B
Z
ABSTRACT Despite remarkable advances in Organ-on-a-chip (Organ Chip) microfluidic culture technology, recreating tissue-relevant physiological conditions, such as the region-specific oxygen concentrations, remains a formidable technical challenge, and analysis of tissue functions is commonly carried out using one analytical technique at a time. Here, we describe two-channel Organ Chip microfluidic devices fabricated from polydimethylsiloxane and gas impermeable polycarbonate materials that are integrated with multiple sensors, mounted on a printed circuit board and operated using a commercially available Organ Chip culture instrument. The novelty of this system is that it enables the recreation of physiologically relevant tissue-tissue interfaces and oxygen tension as well as non-invasive continuous measurement of transepithelial electrical resistance, oxygen concentration and pH, combined with simultaneous analysis of cellular metabolic activity (ATP/ADP ratio), cell morphology, and tissue phenotype. We demonstrate the reliable and reproducible functionality of this system in living human Gut and Liver Chip cultures. Changes in tissue barrier function and oxygen tension along with their functional and metabolic responses to chemical stimuli (e.g., calcium chelation, oligomycin) were continuously and noninvasively monitored on-chip for up to 23 days. A physiologically relevant microaerobic microenvironment that supports co-culture of human intestinal cells with living Lactococcus lactis bacteria also was demonstrated in the Gut Chip. The integration of multi-functional sensors into Organ Chips provides a robust and scalable platform for the simultaneous, continuous, and non-invasive monitoring of multiple physiological functions that can significantly enhance the comprehensive and reliable evaluation of engineered tissues in Organ Chip models in basic research, preclinical modeling, and drug development.
1

Establishment of physiologically relevant oxygen gradients in microfluidic organ chips

Jennifer Grant et al.Jan 30, 2022
+8
D
S
J
Abstract In vitro models of human organs must accurately reconstitute oxygen concentrations and gradients that are observed in vivo to mimic gene expression, metabolism, and host-microbiome interactions. Here we describe a simple strategy to achieve physiologically relevant oxygen tension in a two-channel human small intestine-on-a-chip (Intestine Chip) lined with primary human duodenal epithelium and intestinal microvascular endothelium in parallel channels separated by a porous membrane while both channels are perfused with oxygenated medium. This strategy was developed using computer simulations that predicted lowering the oxygen permeability of poly-dimethlysiloxane (PDMS) chips in specified locations using a gas impermeable film will allow the cells to naturally decrease the oxygen concentration through aerobic respiration and reach steady-state oxygen levels < 36 mm Hg (< 5%) within the epithelial lumen. The approach was experimentally confirmed using chips with embedded oxygen sensors that maintained this stable oxygen gradient. Furthermore, Intestine Chips cultured with this approach supported formation of a villus epithelium interfaced with a continuous endothelium and maintained intestinal barrier integrity for 72 h. This strategy recapitulates in vivo functionality in an efficient, inexpensive, and scalable format that improves the robustness and translatability of Organ Chip technology for studies on microbiome as well as oxygen sensitivity.
1

Enteric coronavirus infection and treatment modeled with an immunocompetent human intestine-on-a-chip

Amir Bein et al.Jun 3, 2021
+20
M
S
A
Abstract Many patients infected with coronaviruses, such as SARS-CoV-2 and NL63 that use ACE2 receptors to infect cells, exhibit gastrointestinal symptoms and viral proteins are found in the human gastrointestinal tract, yet little is known about the inflammatory and pathological effects of coronavirus infection on the human intestine. Here, we used a human intestine-on-a-chip (Intestine Chip) microfluidic culture device lined by patient organoid-derived intestinal epithelium interfaced with human vascular endothelium to study host cellular and inflammatory responses to infection with NL63 coronavirus. These organoid-derived intestinal epithelial cells dramatically increased their ACE2 protein levels when cultured under flow in the presence of peristalsis-like mechanical deformations in the Intestine Chips compared to when cultured statically as organoids or in Transwell inserts. Infection of the intestinal epithelium with NL63 on-chip led to inflammation of the endothelium as demonstrated by loss of barrier function, increased cytokine production, and recruitment of circulating peripheral blood mononuclear cells (PMBCs). Treatment of NL63 infected chips with the approved protease inhibitor drug, nafamostat, inhibited viral entry and resulted in a reduction in both viral load and cytokine secretion, whereas remdesivir, one of the few drugs approved for COVID19 patients, was not found to be effective and it also was toxic to the endothelium. This model of intestinal infection was also used to test the effects of other drugs that have been proposed for potential repurposing against SARS-CoV-2. Taken together, these data suggest that the human Intestine Chip might be useful as a human preclinical model for studying coronavirus related pathology as well as for testing of potential anti-viral or anti-inflammatory therapeutics.