SS
Sachie Shibayama
Author with expertise in Ecology and Evolution of Viruses in Ecosystems
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
3
(100% Open Access)
Cited by:
4
h-index:
4
/
i10-index:
1
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
1

Standardisation of cell-free DNA measurements: An International Study on Comparability of Low Concentration DNA Measurements using cancer variants

Daniel Burke et al.Sep 6, 2023
+28
X
D
D
ABSTRACT For the impact of genomic testing from liquid biopsies to be maximized, mechanisms to ensure reproducible and comparable test performance will be required. This can be established and maintained through reference measurement procedures and materials with property values that are internationally comparable through traceability to a common standard. To achieve this objective, an interlaboratory study was organised to explore digital PCR (dPCR) for standardisation of cell-free DNA (cfDNA) quantification. Blinded samples of wild-type/variant mixtures of two DNA sequences ( BRAF p.V600E single nucleotide variant or EGFR exon 19 deletion) were provided to 12 laboratories. Laboratories independently designed and applied dPCR assays to determine absolute and relative quantities, with no guidance provided to harmonise the approach. The mean and coefficient of variation (CV) of copy number concentrations for variant sequences were 18 copies/μL (CV 7.2%) ( BRAF variant sample) and 9 copies/μL (CV 25%) ( EGFR variant sample) while the mean variant allele frequencies (vAF) were 8.0% (CV 5.3%) and 0.080% (CV 29%) respectively. This study demonstrated that dPCR was capable of exceptional technical accuracy for variant copy number concentration and vAF, even when different assays and platforms were used. This implies that dPCR offers a unique analytical methodology that can be deployed globally in supporting comparability for cfDNA testing based on the existing framework of the International System of units of measurement.
1
Citation2
0
Save
0

CCQM-P199b: Interlaboratory comparability study of SARS-CoV-2 RNA copy number quantification

Alison Devonshire et al.Mar 27, 2024
+68
X
L
A
ABSTRACT Nucleic acid amplification tests including reverse transcription quantitative PCR (RT-qPCR) are used to detect RNA from Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), the causative agent of the Coronavirus disease 2019 (COVID-19) pandemic. Standardized measurements of RNA can facilitate comparable performance of laboratory tests in the absence of existing reference measurement systems early on in a pandemic. Interlaboratory study CCQM P199b “SARS-CoV-2 RNA copy number quantification” was designed to test the fitness-for-purpose of developed candidate reference measurement procedures (RMPs) for SARS-CoV-2 genomic targets in purified RNA materials, and was conducted under the auspices of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) to evaluate the measurement comparability of national metrology institutes (NMIs) and designated institutes (DIs), thereby supporting international standardization. Twenty-one laboratories participated in CCQM P199b and were requested to report the RNA copy number concentration, expressed in number of copies per microliter, of the SARS-CoV-2 nucleocapsid ( N ) gene partial region (NC_045512.2: 28274-29239) and envelope ( E ) gene (NC_045512.2: 26245-26472) (optional measurements) in samples consisting of in vitro transcribed RNA or purified RNA from lentiviral constructs. Materials were provided in two categories: lower concentration (≈ (10 1 -10 4 ) /μL in aqueous solution containing human RNA background) and high concentration (≈ 10 9 /μL in aqueous solution without any other RNA background). For the measurement of N gene concentration in the lower concentration study materials, the majority of laboratories ( n = 17) used one-step reverse transcription-digital PCR (RT-dPCR), with three laboratories applying two-step RT-dPCR and one laboratory RT-qPCR. Sixteen laboratories submitted results for E gene concentration. Reproducibility (% CV or equivalent) for RT-dPCR ranged from 19 % to 31 %. Measurements of the high concentration study material by orthogonal methods (isotope dilution-mass spectrometry and single molecule flow cytometry) and a gravimetrically linked lower concentration material were in a good agreement, suggesting a lack of overall bias in RT-dPCR measurements. However methodological factors such as primer and probe (assay) sequences, RT-dPCR reagents and dPCR partition volume were found to be potential sources of interlaboratory variation which need to be controlled when applying this technique. This study demonstrates that the accuracy of RT-dPCR is fit-for-purpose as a RMP for viral RNA target quantification in purified RNA materials and highlights where metrological approaches such as the use of in vitro transcribed controls, orthogonal methods and measurement uncertainty evaluation can support standardization of molecular methods.
0
Paper
Citation1
0
Save
0

CCQM-P199: Interlaboratory comparability study of HIV-1 RNA copy number quantification

Alison Devonshire et al.Apr 13, 2024
+40
X
D
A
ABSTRACT Infection with human immunodeficiency virus (HIV)-1 leads to acquired immunodeficiency syndrome (AIDS) if left untreated. According to UN figures, approximately 39 million people globally were living with HIV in 2022, with 76% of those individuals accessing antiretroviral therapy. Measurement of plasma viral RNA load using calibrated nucleic acid amplification tests (like reverse transcription quantitative PCR, RT-qPCR) is routinely performed to monitor response to treatment and ultimately prevent viral transmission. RNA quantities measured by commercial tests can vary over many orders of magnitude, from trace single copy levels to, in cases, over 10 9 /mL of plasma, presenting an analytical challenge for calibrating across a broad measurement range. Interlaboratory study CCQM-P199 “HIV-1 RNA copy number quantification” (April to September 2019) was conducted under the auspices of the Consultative Committee for Amount of Substance (CCQM) Nucleic Acid analysis Working Group (NAWG), with the aims of supporting national metrology institutes (NMIs) and designated institutes (DIs) development of the capacity and evaluating candidate reference measurement procedures for applied viral nucleic acid measurements. Thirteen laboratories participated in CCQM-P199 and were requested to report the RNA copy number concentration, expressed in copies per microliter, of the HIV-1 group specific antigen ( gag ) gene of in vitro transcribed RNA molecules at low (≈ 10 3 /μL) and high concentration (≈ 10 9 /μL) (Study Materials 1 and 2, linked by gravimetric dilution) and purified genomic RNA from cultured virus (Study Material 3). Study Materials 1 and 3 were measured by participants using one-step reverse transcription digital PCR (RT-dPCR) (Bio-Rad reagents) and/or two-step RT-dPCR with alternative cDNA synthesis reagents. Study Material 2 was measured by both RT-dPCR (one-step) ( n = 4) and orthogonal methods: single molecule flow cytometric counting ( n = 2), high performance liquid chromatograph (HPLC) ( n = 1) and isotype dilution-mass spectrometry (ID-MS) ( n = 1). Interlaboratory reproducibilities (expressed as %CV) were 21.4 %, 15.3 % and 22.0 % for Study Materials 1, 2 and 3 respectively. Analysis of overdispersion showed that the interlaboratory variation for all three Study Materials was not accounted for in their reported uncertainties, indicating uncharacterized sources of variation remain. Although the mean values of RT-dPCR and orthogonal method results were not statistically significantly different ( p = 0.46), the extrapolated mean Study Material 2 results were higher than mean Study Material 1 results (1196 vs . 808 /μL; p < 0.05). Follow-up analysis of Study Material 2 purity by ultra-performance liquid chromatography (UPLC) indicated higher molecular weight (MW) impurities constituted 16.6 % of the molecules, which are hypothesised to be the cause of the HPLC and ID-MS results being higher than the majority of Study Material 1 and 2 results. This study demonstrates that reproducible measurement of RNA templates was achieved by metrology laboratories, illustrating the potential of RT-dPCR combined with complimentary orthogonal approaches to support traceability and precision of contemporary methods for RNA quantification. This study also highlighted that detailed characterization of RNA materials and sources of bias affecting measurements such as RT efficiency is needed to further establish RT-dPCR as a primary reference measurement procedure for RNA copy number quantification.