MS
Majid Sorkhabi
Author with expertise in Neural Interface Technology
Achievements
Open Access Advocate
Cited Author
Key Stats
Upvotes received:
0
Publications:
6
(100% Open Access)
Cited by:
15
h-index:
7
/
i10-index:
5
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
18

The sensitivity of ECG contamination to surgical implantation site in adaptive neurostimulation

Wolf‐Julian Neumann et al.Jan 17, 2021
+21
M
M
W
Abstract Background Brain sensing devices are approved today for Parkinson’s, essential tremor, and epilepsy therapies. Clinical decisions for implants are often influenced by the premise that patients will benefit from using sensing technology. However, artifacts, such as ECG contamination, can render such treatments unreliable. Therefore, clinicians need to understand how surgical decisions may affect artifact probability. Objectives Investigate neural signal contamination with ECG activity in sensing enabled neurostimulation systems, and in particular clinical choices such as implant location that impact signal fidelity. Methods Electric field modelling and empirical signals from 85 patients were used to investigate the relationship between implant location and ECG contamination.a Results The impact on neural recordings depends on the difference between ECG signal and noise floor of the electrophysiological recording. Empirically, we demonstrate that severe ECG contamination was more than 3.2x higher in left-sided subclavicular implants (48.3%), when compared to right-sided implants (15.3%). Cranial implants did not show ECG contamination. Conclusions Given the relative frequency of corrupted neural signals, we conclude that implant location will impact the ability of brain sensing devices to be used for “closed-loop” algorithms. Clinical adjustments such as implant location can significantly affect signal integrity and need consideration. Highlights Chronic embedded brain sensing promises algorithm-based neurostimulation Algorithms for closed-loop stimulation can be impaired by artifacts The relationship of implant location to cardiac dipole has relevant impact on neural signal fidelity; simple models can provide guidance on the sensitivity ECG artifacts are present in up to 50% of neural signals from left subclavicular DBS systems Implanting DBS in a right subclavicular location significantly reduces frequency of ECG artifacts Cranial-mounted implants are relatively immune to artifacts
2

Physiological Artefacts and the Implications for Brain-Machine-Interface Design

Majid Sorkhabi et al.May 26, 2020
T
P
M
M
Abstract The accurate measurement of brain activity by Brain-Machine-Interfaces (BMI) and closed-loop Deep Brain Stimulators (DBS) is one of the most important steps in communicating between the brain and subsequent processing blocks. In conventional chest-mounted systems, frequently used in DBS, a significant amount of artifact can be induced in the sensing interface, often as a common-mode signal applied between the case and the sensing electrodes. Attenuating this common-mode signal can be a serious challenge in these systems due to finite commonmode-rejection-ratio (CMRR) capability in the interface. Emerging BMI and DBS devices are being developed which can mount on the skull. Mounting the system on the cranial region can potentially suppress these induced physiological signals by limiting the artifact amplitude. In this study, we model the effect of artifacts by focusing on cardiac activity, using a current-source dipole model in a torso-shaped volume conductor. Performing finite element simulation with the different DBS architectures, we estimate the ECG common mode artifacts for several device architectures. Using this model helps define the overall requirements for the total system CMRR to maintain resolution of brain activity. The results of the simulations estimate that the cardiac artifacts for skull-mounted systems will have a significantly lower effect than non-cranial systems that include the pectoral region. It is expected that with a pectoral mounted device, a minimum of 60-80 dB CMRR is required to suppress the ECG artifact, while in cranially-mounted devices, a 20 dB CMRR is sufficient, in the worst-case scenario. The methods used for estimating cardiac artifacts can be extended to other sources such as motion/muscle sources. The susceptibility of the device to artifacts has significant implications for the practical translation of closed-loop DBS and BMI, including the choice of biomarkers and the design requirements for insulators and lead systems.
1

A Neurostimulator System for Real, Sham, and Multi-Target Transcranial Magnetic Stimulation

Majid Sorkhabi et al.Nov 22, 2021
T
M
A bstract Background Transcranial magnetic stimulation (TMS) is a clinically effective therapeutic instrument used to modulate neural activity. Despite three decades of research, two challenging issues remain, the possibility of changing the 1) stimulated spot and 2) stimulation type (real or sham) without physically moving the coil. Objective In this study, a second-generation programmable TMS (pTMS2) device with advanced stimulus shaping is introduced that uses a 5-level cascaded H-bridge inverter and phase-shifted pulse-width modulation (PWM). The principal idea of this research is to obtain real, sham, and multi-locus stimulation with the same TMS system. Methods We propose a two-channel modulation-based magnetic pulse generator and a novel coil arrangement, consisting of two circular coils with a physical distance of 20 mm between the coils and a control method for modifying the effective stimulus intensity, which leads to the live steerability of the location and type of stimulation. Results Based on the measured system performance, the stimulation profile can be steered ± 20 mm along a line from the centroid of the coil locations by modifying the modulation index. Conclusion The proposed system supports electronic control of the stimulation spot without physical coil movement, resulting in tunable modulation of targets, which is a crucial step towards automated TMS machines.
1

Pulse-Width Modulation-based TMS mimics effects of conventional TMS on human primary motor cortex

Majid Sorkhabi et al.Nov 25, 2021
T
J
K
M
A bstract Objective We developed a novel transcranial magnetic stimulation (TMS) device to generate flexible stimuli and patterns. The system synthesizes digital equivalents of analog waveforms, relying on the filtering properties of the nervous system. Here, we test the hypothesis that the novel pulses can mimic the effect of conventional pulses on the cortex. Approach A second-generation programmable TMS (pTMS2) stimulator with magnetic pulse shaping capabilities using pulse-width modulation (PWM) was tested. A computational and an in-human study on twelve healthy participants compared the neuronal effects of conventional and modulation-based stimuli. Main results Both the computational modeling and the in-human stimulation showed that the PWM-based system can synthesize pulses to effectively stimulate the human brain, equivalent to conventional stimulators. The comparison includes motor threshold, MEP latency and input-output curve measurements. Significance PWM stimuli can fundamentally imitate the effect of conventional magnetic stimuli while adding considerable flexibility to TMS systems, enabling the generation of highly configurable TMS protocols. H ighlights The PWM method promises the implementation of flexible neurostimulation PWM magnetic pulses were well tolerated by the participants without adverse events RMTs and MEPs were compared for PWM and conventional stimuli PWM-equivalent of conventional pulses has relatively similar effects on the cortex The use of digital synthesis techniques to create novel patterns is a promising method for future neuromodulation
3

Practical Design and Implementation of Animal Movements Tracking System for Neuroscience Trials

Majid SorkhabiJul 26, 2020
M
A bstract Background The nervous system functions of an animal are predominantly reflected in the behaviour and the movement, therefore the movement-related data and measuring behavior quantitatively are crucial for behavioural analyses. The animal movement is traditionally recorded, and human observers follow the animal behaviours; if they recognize a certain behaviour pattern, they will note it manually, which may suffer from observer fatigue or drift. Objective Automating behavioural observations with computer-vision algorithms are becoming essential equipment to the brain function characterization in neuroscience trials. In this study, the proposed tracking module is eligible to measure the locomotor behaviour (such as speed, distance, turning) over longer time periods that the operator is unable to precisely evaluate. For this aim, a novel animal cage is designed and implemented to track the animal movement. The frames received from the camera are analyzed by the 2D bior 3.7 Wavelet transform and SURF feature points. Results Implemented video tracking device can report the location, duration, speed, frequency and latency of each behavior of an animal. Validation tests were conducted on the auditory stimulation trial and the magnetic stimulation treatment of hemi-Parkinsonian rats. Conclusion/ Significance The proposed toolkit can provide qualitative and quantitative data on animal behaviour in an automated fashion, and precisely summarize an animal’s movement at an arbitrary time and allows operators to analyse movement patterns without requiring to check full records for every experiment.
2

The effect of pulse shape in theta-burst stimulation: monophasic vs biphasic TMS

Karen Wendt et al.Mar 7, 2023
+3
C
M
K
Abstract Background Intermittent theta-burst stimulation (i)(TBS) is a transcranial magnetic stimulation (TMS) plasticity protocol. Conventionally, TBS is applied using biphasic pulses due to hardware limitations. However, monophasic pulses are hypothesised to recruit cortical neurons more selectively than biphasic pulses, thus yielding stronger plasticity effects. Monophasic and biphasic TBS can be generated using a custom-made pulse-width modulation-based TMS device (pTMS). Objective Using pTMS, we tested the hypothesis that monophasic iTBS would induce greater plasticity effects than biphasic, measured as induced changes in motor corticospinal excitability. Methods In a repeated-measures design, thirty healthy volunteers participated in three separate sessions, where monophasic and biphasic iTBS was applied to the primary motor cortex (M1 condition) or the vertex (control condition). Plasticity was quantified as changes in motor corticospinal excitability after versus before iTBS, by comparing peak-to-peak amplitudes of motor evoked potentials (MEP) measured at baseline and over 60 minutes after iTBS. Results Both monophasic and biphasic M1 iTBS led to significant increases in MEP amplitude. As predicted, monophasic iTBS induced a significantly larger effect than biphasic iTBS (linear mixed effect model analysis: (χ 2 (1) = 7.48, p = 0.006), which persisted even after subtracting each individual’s control (vertex) condition data from the M1 conditions (χ 2 (1) = 5.48, p = 0.019). Conclusions In this study, monophasic iTBS induced a stronger motor corticospinal excitability increase than biphasic within participants. This greater physiological effect suggests that monophasic iTBS may also have potential for greater functional impact, of interest for future fundamental and clinical applications of TBS.