AK
Adil Khan
Author with expertise in Coronavirus Disease 2019 Research
Achievements
Open Access Advocate
Cited Author
Key Stats
Upvotes received:
0
Publications:
5
(60% Open Access)
Cited by:
12
h-index:
14
/
i10-index:
17
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
1

Epigallocatechin Gallate from Green Tea Effectively Blocks Infection of SARS-CoV-2 and New Variants by Inhibiting Spike Binding to ACE2 Receptor

Jinbiao Liu et al.Mar 17, 2021
Abstract As the COVID-19 pandemic rages on, the new SARS-CoV-2 variants have emerged in the different regions of the world. These newly emerged variants have mutations in their spike (S) protein that may confer resistance to vaccine-elicited immunity and existing neutralizing antibody therapeutics. Therefore, there is still an urgent need of safe, effective, and affordable agents for prevention/treatment of SARS-CoV-2 and its variant infection. Here, we demonstrated that green tea beverage (GTB) or its major ingredient, epigallocatechin gallate (EGCG), were highly effective in inhibiting infection of live SARS-CoV-2 and human coronavirus (HCoV OC43). In addition, infection of the pseudoviruses with spikes of the new variants (UK-B.1.1.7, SA-B.1.351, and CA-B.1.429) was efficiently blocked by GTB or EGCG. Among the 4 active green tea catechins at noncytotoxic doses, EGCG was the most potent in the action against the viruses. The highest inhibitory activity was observed when the viruses or the cells were pre-incubated with EGCG prior to the infection. Mechanistic studies revealed that EGCG blocked infection at the entry step through interfering with the engagement of the receptor binding domain (RBD) of the viral spikes to angiotensin-converting enzyme 2 (ACE2) receptor of the host cells. These data support further clinical evaluation and development of EGCG as a novel, safe, and cost-effective natural product for prevention/treatment of SARS-CoV-2 transmission and infection.
1
Citation7
0
Save
0

Not all marketed skin cleansers’ pH is optimal for atopic dermatitis

Adil Khan et al.Jul 1, 2024
Background: The normally acidic skin pH changes in atopic dermatitis (AD) to alkaline, which contributes to the associated skin-barrier dysfunction. Hence, acidic cleansers would be preferred, but such information is scarce. Objective: Guiding health-care providers and patients on selecting skin cleansers with a pH optimal for AD. Methods: A total of 250 products were tested: 37 soaps (32 bars, 5 liquid) and 213 syndets (14 bars, 199 liquid); 10% solutions were tested for pH by using a pH meter; pH values 6.65‐7.35 were considered neutral. Results: The pH of the tested skin cleansers varied widely (3.59‐10.83). All 37 soaps were highly alkaline. In the 14 syndet bars, the pH was neutral in 6, alkaline in 8, and acidic in none. In the 199 syndet liquids, the pH was acidic in 84.9%, neutral in 11.1%, and alkaline in 4.0%. The product’s pH was disclosed in none of the 37 soaps and in only 32 syndets (15%) , of which 9 bars were labeled “balanced,” whose measured pH was neutral in 6 and alkaline in 3. Of the other 23 syndets, the labeled pH was referred to as “balanced” in 20 whose measured pH was neutral in 2 (6.80, 6.88) and acidic in 18 (3.59‐6.59). The pH in the other three syndets was 4.25‐6.00. Conclusion: All tested soaps had undesirable pH, whereas 84.9% of the liquid syndets were acidic (which is desirable) and 11.1% were neutral (which could be acceptable). Only 12.8% of the products disclosed the pH, an issue in need of improvement.
0
Citation1
0
Save
0

Point-of-care testing: state-of-the art and perspectives

Mario Plebani et al.Jun 17, 2024
Abstract Point-of-care testing (POCT) is becoming an increasingly popular way to perform laboratory tests closer to the patient. This option has several recognized advantages, such as accessibility, portability, speed, convenience, ease of use, ever-growing test panels, lower cumulative healthcare costs when used within appropriate clinical pathways, better patient empowerment and engagement, and reduction of certain pre-analytical errors, especially those related to specimen transportation. On the other hand, POCT also poses some limitations and risks, namely the risk of lower accuracy and reliability compared to traditional laboratory tests, quality control and connectivity issues, high dependence on operators (with varying levels of expertise or training), challenges related to patient data management, higher costs per individual test, regulatory and compliance issues such as the need for appropriate validation prior to clinical use (especially for rapid diagnostic tests; RDTs), as well as additional preanalytical sources of error that may remain undetected in this type of testing, which is usually based on whole blood samples (i.e., presence of interfering substances, clotting, hemolysis, etc.). There is no doubt that POCT is a breakthrough innovation in laboratory medicine, but the discussion on its appropriate use requires further debate and initiatives. This collective opinion paper, composed of abstracts of the lectures presented at the two-day expert meeting “Point-Of-Care-Testing: State of the Art and Perspective” (Venice, April 4–5, 2024), aims to provide a thoughtful overview of the state-of-the-art in POCT, its current applications, advantages and potential limitations, as well as some interesting reflections on the future perspectives of this particular field of laboratory medicine.
0
Citation1
0
Save