AL
Antonio León
Author with expertise in Computational Methods in Drug Discovery
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
4
(75% Open Access)
Cited by:
2
h-index:
16
/
i10-index:
22
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
1

Improving the Assessment of Deep Learning Models in the Context of Drug-Target Interaction Prediction

Mirko Torrisi et al.Apr 21, 2022
A bstract Machine Learning techniques have been widely adopted to predict drug-target interactions, a central area of research in early drug discovery. These techniques have shown promising results on various benchmarks although they tend to suffer from poor generalization. This is typically related to very sparse and nonuniform datasets available, which limits the applicability domain of machine learning techniques. Moreover, widespread approaches to split datasets (into training and test sets) treat a drug-target interaction as an independent entities, when in reality the drug and target involved may take part in other interactions, breaking apart the assumption of independence. We observe that this leads to overly optimistic test results and poor generalization of out-of-distribution samples for various state-of-the-art sequence-based machine learning models for drug-target prediction. We show that previous approaches to reduce bias in binding datasets focus on drug or target information only and, thus, lead to similar pitfalls. Finally, we propose a minimum viable solution to evaluate the generalization capability of a machine learning model based on the systematic separation of test samples with respect to drugs and targets in the training set, thus discerning the three out-of-distribution scenarios seen at test time: (1) drug or (2) target present in the training set, or (3) neither.
0

Development and implementation of a measurement system for PTW water phantom in the determination of absorbed dose to water

Antonio León et al.Jan 7, 2025
At Secondary Standard Dosimetry Laboratory (SSDL) in Venezuela is the only one in the country that performs calibrations of dosimetry systems with an IAEA water phantom. However, SSDL has a PTW water phantom, for which there is no procedure for the calibration of dosimetry systems. Therefore, a methodology was developed for its validation using a cobalt-60 equipment, a secondary standard, an IAEA water phantom and a PTW phantom. The adapter for ionization chamber type NE 2561 was studied and designed to protect it from water. The methodology consisted of calculate of absorbed dose rate to water in IAEA water phantom and PTW water phantom. Subsequently, the absorbed dose rates to water were compared between both phantoms and finally, the validation of the new procedures and their respective uncertainties was performed. The adapter of ionization chamber was built with PMMA material. Comparisons between absorbed dose rates to water showed that there is no difference between the two phantoms. The absorbed dose rate to water was calculated with the procedure updates along with their associated uncertainties, obtaining =0.13482 ± 0.00292 Gy/min. Finally, the validation obtained a value of less than 0.7%, which means that the implementation of the new procedures for the calibration of dosimetry systems is valid and applied at the SSDL-Venezuela.