Healthy Research Rewards
ResearchHub is incentivizing healthy research behavior. At this time, first authors of open access papers are eligible for rewards. Visit the publications tab to view your eligible publications.
Got it
BM
Bernhard Meyer
Author with expertise in Epidemiology and Treatment of Meningiomas
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
38
(63% Open Access)
Cited by:
2,884
h-index:
73
/
i10-index:
468
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical Robot

Dennis Devito et al.Nov 1, 2010
In Brief Study Design. Retrospective, multicenter study of robotically-guided spinal implant insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph, and when available, postoperative computed tomography (CT) scans were used to determine placement accuracy. Objective. To verify the clinical acceptance and accuracy of robotically-guided spinal implants and compare to those of unguided free-hand procedures. Summary of Background Data. SpineAssist surgical robot has been used to guide implants and guide-wires to predefined locations in the spine. SpineAssist which, to the best of the authors' knowledge, is currently the sole robot providing surgical assistance in positioning tools in the spine, guided over 840 cases in 14 hospitals, between June 2005 and June 2009. Methods. Clinical acceptance of 3271 pedicle screws and guide-wires inserted in 635 reported cases was assessed by intraoperative fluoroscopy, where placement accuracy of 646 pedicle screws inserted in 139 patients was measured using postoperative CT scans. Results. Screw placements were found to be clinically acceptable in 98% of the cases when intraoperatively assessed by fluoroscopic images. Measurements derived from postoperative CT scans demonstrated that 98.3% of the screws fell within the safe zone, where 89.3% were completely within the pedicle and 9% breached the pedicle by up to 2 mm. The remaining 1.4% of the screws breached between 2 and 4 mm, while only 2 screws (0.3%) deviated by more than 4 mm from the pedicle wall. Neurologic deficits were observed in 4 cases yet, following revisions, no permanent nerve damage was encountered, in contrast to the 0.6% to 5% of neurologic damage reported in the literature. Conclusion. SpineAssist offers enhanced performance in spinal surgery when compared to free-hand surgeries, by increasing placement accuracy and reducing neurologic risks. In addition, 49% of the cases reported herein used a percutaneous approach, highlighting the contribution of SpineAssist in procedures without anatomic landmarks. This work describes a retrospective study of pedicle screws and guide-wires insertion under the guidance of the SpineAssist robotic platform. SpineAssist enhanced clinical acceptance, positioning accuracy, and reduced neurologic risks. Furthermore, its contribution was most appreciated with percutaneous approach, when anatomic landmarks are not visible.
0
Paper
Citation362
0
Save
0

Accuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle Screws

Florian Ringel et al.Feb 4, 2012
Single-center prospective randomized controlled study.To evaluate the accuracy of robot-assisted (RO) implantation of lumbar/sacral pedicle screws in comparison with the freehand (FH) conventional technique.SpineAssist is a miniature robot for the implantation of thoracic, lumbar, and sacral pedicle screws. The system, studied in cadaver and cohort studies, revealed a high accuracy, so far. A direct comparison of the robot assistance with the FH technique is missing.Patients requiring mono- or bisegmental lumbar or lumbosacral stabilization were randomized in a 1:1 ratio to FH or RO pedicle screw implantation. Instrumentation was performed using fluoroscopic guidance (FH) or robot assistance. The primary end point screw position was assessed by a postoperative computed tomography, and screw position was classified (A: no cortical violation; B: cortical breach <2 mm; C: ≥2 mm to <4 mm; D: ≥4 mm to <6 mm; E: ≥6 mm). Secondary end points as radiation exposure, duration of surgery/planning, and hospital stay were assessed.A total of 298 pedicle screws were implanted in 60 patients (FH, 152; RO, 146). Ninety-three percent had good positions (A or B) in FH, and 85% in RO. Preparation time in the operating room (OR), overall OR time, and intraoperative radiation time were not different for both groups. Surgical time for screw placement was significantly shorter for FH (84 minutes) than for RO (95 minutes). Ten RO screws required an intraoperative conversion to the FH. One FH screw needed a secondary revision.In this study, the accuracy of the conventional FH technique was superior to the RO technique. Most malpositioned screws of the RO group showed a lateral deviation. Attachment of the robot to the spine seems a vulnerable aspect potentially leading to screw malposition as well as slipping of the implantation cannula at the screw entrance point.
0
Paper
Citation308
0
Save
0

A Comparison of Language Mapping by Preoperative Navigated Transcranial Magnetic Stimulation and Direct Cortical Stimulation During Awake Surgery

Thomas Picht et al.Feb 5, 2013
BACKGROUND: Navigated transcranial magnetic stimulation (nTMS) is increasingly used in presurgical brain mapping. Preoperative nTMS results correlate well with direct cortical stimulation (DCS) data in the identification of the primary motor cortex. Repetitive nTMS can also be used for mapping of speech-sensitive cortical areas. OBJECTIVE: The current cohort study compares the safety and effectiveness of preoperative nTMS with DCS mapping during awake surgery for the identification of language areas in patients with left-sided cerebral lesions. METHODS: Twenty patients with tumors in or close to left-sided language eloquent regions were examined by repetitive nTMS before surgery. During awake surgery, language-eloquent cortex was identified by DCS. nTMS results were compared for accuracy and reliability with regard to DCS by projecting both results into the cortical parcellation system. RESULTS: Presurgical nTMS maps showed an overall sensitivity of 90.2%, specificity of 23.8%, positive predictive value of 35.6%, and negative predictive value of 83.9% compared with DCS. For the anatomic Broca's area, the corresponding values were a sensitivity of 100%, specificity of 13.0%, positive predictive value of 56.5%, and negative predictive value of 100%, respectively. CONCLUSION: Good overall correlation between repetitive nTMS and DCS was observed, particularly with regard to negatively mapped regions. Noninvasive inhibition mapping with nTMS is evolving as a valuable tool for preoperative mapping of language areas. Yet its low specificity in posterior language areas in the current study necessitates further research to refine the methodology. ABBREVIATIONS: DCS, direct cortical stimulation fMRI, functional magnetic resonance imaging nTMS, navigated transcranial magnetic stimulation RMT, resting motor threshold rTMS, repetitive transcranial magnetic stimulation TMS, transcranial magnetic stimulation
0

Improvement of Cognitive Function After Cochlear Implantation in Elderly Patients

Isabelle Mosnier et al.Mar 12, 2015
The association between hearing impairment and cognitive decline has been established; however, the effect of cochlear implantation on cognition in profoundly deaf elderly patients is not known.To analyze the relationship between cognitive function and hearing restoration with a cochlear implant in elderly patients.Prospective longitudinal study performed in 10 tertiary referral centers between September 1, 2006, and June 30, 2009. The participants included 94 patients aged 65 to 85 years with profound, postlingual hearing loss who were evaluated before, 6 months after, and 12 months after cochlear implantation.Cochlear implantation and aural rehabilitation program.Speech perception was measured using disyllabic word recognition tests in quiet and in noise settings. Cognitive function was assessed using a battery of 6 tests evaluating attention, memory, orientation, executive function, mental flexibility, and fluency (Mini-Mental State Examination, 5-word test, clock-drawing test, verbal fluency test, d2 test of attention, and Trail Making test parts A and B). Quality of life and depression were evaluated using the Nijmegen Cochlear Implant Questionnaire and the Geriatric Depression Scale-4.Cochlear implantation led to improvements in speech perception in quiet and in noise (at 6 months: in quiet, 42% score increase [95% CI, 35%-49%; P < .001]; in noise, at signal to noise ratio [SNR] +15 dB, 44% [95% CI, 36%-52%, P < .001], at SNR +10 dB, 37% [95% CI 30%-44%; P < .001], and at SNR +5 dB, 27% [95% CI, 20%-33%; P < .001]), quality of life, and Geriatric Depression Scale-4 scores (76% of patients gave responses indicating no depression at 12 months after implantation vs 59% before implantation; P = .02). Before cochlear implantation, 44% of the patients (40 of 91) had abnormal scores on 2 or 3 of 6 cognition tests. One year after implant, 81% of the subgroup (30 of 37) showed improved global cognitive function (no or 1 abnormal test score). Improved mean scores in all cognitive domains were observed as early as 6 months after cochlear implantation. Cognitive performance remained stable in the remaining 19% of the participants (7 of 37). Among patients with the best cognitive performance before implantation (ie, no or 1 abnormal cognitive test score), 24% (12 of 50) displayed a slight decline in cognitive performance. Multivariate analysis to examine the association between cognitive abilities before implantation and the variability in cochlear implant outcomes demonstrated a significant effect only between long-term memory and speech perception in noise at 12 months (SNR +15 dB, P = .01; SNR +10 dB, P < .001; and SNR +5 dB, P = .02).Rehabilitation of hearing communication through cochlear implantation in elderly patients results in improvements in speech perception and cognitive abilities and positively influences their social activity and quality of life. Further research is needed to assess the long-term effect of cochlear implantation on cognitive decline.
0

Clinical benefit from resection of recurrent glioblastomas: results of a multicenter study including 503 patients with recurrent glioblastomas undergoing surgical resection

Florian Ringel et al.Aug 4, 2015
While standards for the treatment of newly diagnosed glioblastomas exist, therapeutic regimens for tumor recurrence remain mostly individualized. The role of a surgical resection of recurrent glioblastomas remains largely unclear at present. This study aimed to assess the effect of repeated resection of recurrent glioblastomas on patient survival. In a multicenter retrospective-design study, patients with primary glioblastomas undergoing repeat resections for recurrent tumors were evaluated for factors affecting survival. Age, Karnofsky performance status (KPS), extent of resection (EOR), tumor location, and complications were assessed. Five hundred and three patients (initially diagnosed between 2006 and 2010) undergoing resections for recurrent glioblastoma at 20 institutions were included in the study. The patients’ median overall survival after initial diagnosis was 25.0 months and 11.9 months after first re-resection. The following parameters were found to influence survival significantly after first re-resection: preoperative and postoperative KPS, EOR of first re-resection, and chemotherapy after first re-resection. The rate of permanent new deficits after first re-resection was 8%. The present study supports the view that surgical resections of recurrent glioblastomas may help to prolong patient survival at an acceptable complication rate.
0
Citation212
0
Save
0

Utility of presurgical navigated transcranial magnetic brain stimulation for the resection of tumors in eloquent motor areas

Sandro Krieg et al.Feb 3, 2012
Navigated transcranial magnetic stimulation (nTMS) is a newly evolving technique. Despite its supposed purpose (for example, preoperative central region mapping), little is known about its accuracy compared with established modalities like direct cortical stimulation (DCS) and functional MR (fMR) imaging. Against this background, the authors performed the current study to compare the accuracy of nTMS with DCS and fMR imaging.Fourteen patients with tumors in or close to the precentral gyrus were examined using nTMS for motor cortex mapping, as were 12 patients with lesions in the subcortical white matter motor tract. Moreover, preoperative fMR imaging and intraoperative mapping of the motor cortex were performed via DCS, and the outlining of the motor cortex was compared.In the 14 cases of lesions affecting the precentral gyrus, the primary motor cortex as outlined by nTMS correlated well with that delineated by intraoperative DCS mapping, with a deviation of 4.4 ± 3.4 mm between the two methods. In comparing nTMS with fMR imaging, the deviation between the two methods was much larger: 9.8 ± 8.5 mm for the upper extremity and 14.7 ± 12.4 mm for the lower extremity. In 13 of 14 cases, the surgeon admitted easier identification of the central region because of nTMS. The procedure had a subjectively positive influence on the operative results in 5 cases and was responsible for a changed resection strategy in 2 cases. One of 26 patients experienced nTMS as unpleasant; none found it painful.Navigated TMS correlates well with DCS as a gold standard despite factors that are supposed to contribute to the inaccuracy of nTMS. Moreover, surgeons have found nTMS to be an additional and helpful modality during the resection of tumors affecting eloquent motor areas, as well as during preoperative planning.
0

Balloon pulmonary angioplasty for inoperable patients with chronic thromboembolic pulmonary hypertension: the initial German experience

Karen Olsson et al.Jun 1, 2017
Balloon pulmonary angioplasty (BPA) is an emerging treatment for patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH). We report on a prospective series of 56 consecutive patients who underwent 266 BPA interventions (median, five per patient) at two German institutions. All patients underwent a comprehensive diagnostic work-up including right heart catheterisation at baseline and 24 weeks after their last intervention. BPA resulted in improvements in WHO functional class, 6 min walk distance (mean change, +33 m), right ventricular function and haemodynamics, including a decline in mean pulmonary artery pressure by 18% and in pulmonary vascular resistance by 26%. Procedure-related adverse events occurred in 9.4% of the interventions. The most common complications were related to pulmonary vascular injury and consecutive pulmonary bleeding. Most of these events were asymptomatic and self-limiting, but one patient died from pulmonary bleeding, resulting in a mortality rate of 1.8%. BPA resulted in haemodynamic and clinical improvements but was also associated with a considerable number of complications, including one fatal pulmonary bleeding. As the effects of BPA on survival are unknown, randomised controlled outcome trials comparing BPA with approved medical therapies in patients with inoperable CTEPH are required to allow for appropriate risk–benefit assessments.
Load More