BA
Baptiste Abeloos
Author with expertise in Particle Physics and High-Energy Collider Experiments
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
22
(95% Open Access)
Cited by:
6,295
h-index:
84
/
i10-index:
332
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Measurements of the Higgs boson production and decay rates and constraints on its couplings from a combined ATLAS and CMS analysis of the LHC pp collision data at s = 7 $$ \sqrt{s}=7 $$ and 8 TeV

G. Aad et al.Aug 1, 2016
Combined ATLAS and CMS measurements of the Higgs boson production and decay rates, as well as constraints on its couplings to vector bosons and fermions, are presented. The combination is based on the analysis of five production processes, namely gluon fusion, vector boson fusion, and associated production with a W or a Z boson or a pair of top quarks, and of the six decay modes H → ZZ, W W , γγ, ττ, bb, and μμ. All results are reported assuming a value of 125.09 GeV for the Higgs boson mass, the result of the combined measurement by the ATLAS and CMS experiments. The analysis uses the CERN LHC proton-proton collision data recorded by the ATLAS and CMS experiments in 2011 and 2012, corresponding to integrated luminosities per experiment of approximately 5 fb−1 at $$ \sqrt{s}=7 $$ TeV and 20 fb−1 at $$ \sqrt{s}=8 $$ TeV. The Higgs boson production and decay rates measured by the two experiments are combined within the context of three generic parameterisations: two based on cross sections and branching fractions, and one on ratios of coupling modifiers. Several interpretations of the measurements with more model-dependent parameterisations are also given. The combined signal yield relative to the Standard Model prediction is measured to be 1.09 ± 0.11. The combined measurements lead to observed significances for the vector boson fusion production process and for the H → ττ decay of 5.4 and 5.5 standard deviations, respectively. The data are consistent with the Standard Model predictions for all parameterisations considered.
0
Paper
Citation807
0
Save
0

Muon reconstruction performance of the ATLAS detector in proton–proton collision data at $$\sqrt{s}$$ s =13 TeV

G. Aad et al.May 1, 2016
This article documents the performance of the ATLAS muon identification and reconstruction using the LHC dataset recorded at $$\sqrt{s} = 13$$ TeV in 2015. Using a large sample of $$J/\psi \rightarrow \mu \mu $$ and $$Z\rightarrow \mu \mu $$ decays from 3.2 fb $$^{-1}$$ of pp collision data, measurements of the reconstruction efficiency, as well as of the momentum scale and resolution, are presented and compared to Monte Carlo simulations. The reconstruction efficiency is measured to be close to $$99~\%$$ over most of the covered phase space ( $$|\eta |<2.5$$ and $$5 < p_{\mathrm {T}} < 100$$ GeV). The isolation efficiency varies between 93 and $$100~\%$$ depending on the selection applied and on the momentum of the muon. Both efficiencies are well reproduced in simulation. In the central region of the detector, the momentum resolution is measured to be $$1.7~\%$$ ( $$2.3~\%$$ ) for muons from $$J/\psi \rightarrow \mu \mu $$ ( $$Z\rightarrow \mu \mu $$ ) decays, and the momentum scale is known with an uncertainty of $$0.05~\%$$ . In the region $$|\eta |>2.2$$ , the $$p_{\mathrm {T}} $$ resolution for muons from $$Z\rightarrow \mu \mu $$ decays is $$2.9~\%$$ while the precision of the momentum scale for low- $$p_{\mathrm {T}} $$ muons from $$J/\psi \rightarrow \mu \mu $$ decays is about $$0.2~\%$$ .
0
Paper
Citation534
0
Save
0

Jet energy scale measurements and their systematic uncertainties in proton-proton collisions at s=13  TeV with the ATLAS detector

M. Aaboud et al.Oct 13, 2017
Jet energy scale measurements and their systematic uncertainties are reported for jets measured with the ATLAS detector using proton-proton collision data with a center-of-mass energy of s=13 TeV, corresponding to an integrated luminosity of 3.2 fb−1 collected during 2015 at the LHC. Jets are reconstructed from energy deposits forming topological clusters of calorimeter cells, using the anti-kt algorithm with radius parameter R=0.4. Jets are calibrated with a series of simulation-based corrections and in situ techniques. In situ techniques exploit the transverse momentum balance between a jet and a reference object such as a photon, Z boson, or multijet system for jets with 200.8) is derived from dijet pT balance measurements. For jets of pT=80 GeV, the additional uncertainty for the forward jet calibration reaches its largest value of about 2% in the range |η|>3.5 and in a narrow slice of 2.2<|η|<2.4.8 MoreReceived 29 March 2017DOI:https://doi.org/10.1103/PhysRevD.96.072002Published by the American Physical Society under the terms of the Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.© 2017 CERN, for the ATLAS CollaborationPhysics Subject Headings (PhySH)TechniquesHadron collidersParticle detectorsParticles & Fields
0

Performance of missing transverse momentum reconstruction with the ATLAS detector using proton–proton collisions at $$\sqrt{s}=13~\hbox {TeV}$$ s = 13 TeV

M. Aaboud et al.Nov 1, 2018
The performance of the missing transverse momentum (E$_{T}^{miss}$) reconstruction with the ATLAS detector is evaluated using data collected in proton-proton collisions at the LHC at a center-of-mass energy of 13 TeV in 2015. To reconstruct E$_{T}^{miss}$, fully calibrated electrons, muons, photons, hadronically decaying $\tau$-leptons, and jets reconstructed from calorimeter energy deposits and charged-particle tracks are used. These are combined with the soft hadronic activity measured by reconstructed charged-particle tracks not associated with the hard objects. Possible double counting of contributions from reconstructed charged-particle tracks from the inner detector, energy deposits in the calorimeter, and reconstructed muons from the muon spectrometer is avoided by applying a signal ambiguity resolution procedure which rejects already used signals when combining the various E$_{T}^{miss}$ contributions. The individual terms as well as the overall reconstructed E$_{T}^{miss}$ are evaluated with various performance metrics for scale (linearity), resolution, and sensitivity to the data-taking conditions. The method developed to determine the systematic uncertainties of the E$_{T}^{miss}$ scale and resolution is discussed. Results are shown based on the full 2015 data sample corresponding to an integrated luminosity of 3.2 fb$^{-1}$.
Load More