GT
Gianluca Tartaglia
Author with expertise in Diagnosis and Management of Sjögren's Syndrome
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
13
(62% Open Access)
Cited by:
163
h-index:
44
/
i10-index:
119
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
2

Recent advances in graphene-based nanobiosensors for salivary biomarker detection

Riccardo Goldoni et al.Jan 1, 2021
As biosensing research is rapidly advancing due to significant developments in materials, chemistry, and electronics, researchers strive to build cutting-edge biomedical devices capable of detecting health-monitoring biomarkers with high sensitivity and specificity. Biosensors using nanomaterials are highly promising because of the wide detection range, fast response time, system miniaturization, and enhanced sensitivity. In the recent development of biosensors and electronics, graphene has rapidly gained popularity due to its superior electrical, biochemical, and mechanical properties. For biomarker detection, human saliva offers easy access with a large variety of analytes, making it a promising candidate for its use in point-of-care (POC) devices. Here, we report a comprehensive review that summarizes the most recent graphene-based nanobiosensors and oral bioelectronics for salivary biomarker detection. We discuss the details of structural designs of graphene electronics, use cases of salivary biomarkers, the performance of existing sensors, and applications in health monitoring. This review also describes current challenges in materials and systems and future directions of the graphene bioelectronics for clinical POC applications. Collectively, the main contribution of this paper is to deliver an extensive review of the graphene-enabled biosensors and oral electronics and their successful applications in human salivary biomarker detection.
2
Citation58
0
Save
5

Malignancies and Biosensors: A Focus on Oral Cancer Detection through Salivary Biomarkers

Riccardo Goldoni et al.Oct 15, 2021
Oral cancer is among the deadliest types of malignancy due to the late stage at which it is usually diagnosed, leaving the patient with an average five-year survival rate of less than 50%. The booming field of biosensing and point of care diagnostics can, in this regard, play a major role in the early detection of oral cancer. Saliva is gaining interest as an alternative biofluid for non-invasive diagnostics, and many salivary biomarkers of oral cancer have been proposed. While these findings are promising for the application of salivaomics tools in routine practice, studies on larger cohorts are still needed for clinical validation. This review aims to summarize the most recent development in the field of biosensing related to the detection of salivary biomarkers commonly associated with oral cancer. An introduction to oral cancer diagnosis, prognosis and treatment is given to define the clinical problem clearly, then saliva as an alternative biofluid is presented, along with its advantages, disadvantages, and collection procedures. Finally, a brief paragraph on the most promising salivary biomarkers introduces the sensing technologies commonly exploited to detect oral cancer markers in saliva. Hence this review provides a comprehensive overview of both the clinical and technological advantages and challenges associated with oral cancer detection through salivary biomarkers.
5
Citation40
0
Save
3

Salivary biomarkers: novel noninvasive tools to diagnose chronic inflammation

Paola Dongiovanni et al.Jun 29, 2023
Abstract Several chronic disorders including type 2 diabetes (T2D), obesity, heart disease and cancer are preceded by a state of chronic low-grade inflammation. Biomarkers for the early assessment of chronic disorders encompass acute phase proteins (APP), cytokines and chemokines, pro-inflammatory enzymes, lipids and oxidative stress mediators. These substances enter saliva through the blood flow and, in some cases, there is a close relation between their salivary and serum concentration. Saliva can be easily collected and stored with non-invasive and cost-saving procedures, and it is emerging the concept to use it for the detection of inflammatory biomarkers. To this purpose, the present review aims to discuss the advantages and challenges of using standard and cutting-edge techniques to discover salivary biomarkers which may be used in diagnosis/therapy of several chronic diseases with inflammatory consequences with the pursuit to possibly replace conventional paths with detectable soluble mediators in saliva. Specifically, the review describes the procedures used for saliva collection, the standard approaches for the measurement of salivary biomarkers and the novel methodological strategies such as biosensors to improve the quality of care for chronically affected patients.
3
Citation17
0
Save
2

Redox Profiling of Selected Apulian Red Wines in a Single Minute

Douglas Thomaz et al.Apr 27, 2022
Wine is a complex bioproduct whose chemical composition is highly variable across production regions. In order to shed light on affordable ways to promote the characterization of wines and explore the physicochemical basis of their antioxidant capacity, this work reported on the quick and easy redox profiling of selected red wines from Apulia, Italy. Therefore, an affordable and quickly performed semiempirical quantum chemistry approach, i.e., the extended Hückel method, was used to compute the bandgaps of the main phytochemical markers attributed to red wines. The findings of these calculations were then compared to an electroanalytical investigation in the form of cyclic and square-wave voltammetry, and the electric current of the redox profiles was used as the input dataset for principal component analysis. Results showcased that the semiempirical quantum chemistry calculations allowed the correlation of the bandgaps to the observed faradaic signals upon voltammetry; thereby, also providing insights on their antioxidant appeal by highlighting the feasibility of charge-transfer processes at low electric potentials. Furthermore, the principal component analysis showed that the electric current dataset gathered in a time span of 55 s allowed the appropriate separation of the samples, which hints at the possible use of quick voltammetric assays as fingerprinting tools.
3

Effect of Recombinant Antibodies and MIP Nanoparticles on the Electrical Behavior of Impedimetric Biorecognition Surfaces for SARS-CoV-2 Spike Glycoprotein: A Short Report

Douglas Thomaz et al.Sep 2, 2022
Electrochemical immunosensors are often described as innovative strategies to tackle urgent epidemiological needs, such as the detection of SARS-CoV-2 main biomarker, the spike glycoprotein. Nevertheless, there is a great variety of receptors, especially recombinant antibodies, that can be used to develop these biosensing platforms, and very few reports compare their suitability in analytical device design and their sensing performances. Therefore, this short report targeted a brief and straightforward investigation of the performance of different impedimetric biorecognition surfaces (BioS) for SARS-CoV-2, which were crafted from three commonly reported recombinant antibodies and molecularly-imprinted polymer (MIP) nanoparticles (nanoMIP). The selected NanoMIP were chosen due to their reported selectivity to the receptor binding domain (RBD) of SARS-CoV-2 spike glycoprotein. Results showed that the surface modification protocol based on MUDA and crosslinking with EDC/NHS was successful for the anchoring of each tested receptor, as the semicircle diameter of the Nyquist plots of EIS increased upon each modification, which suggests the increase of Rct due to the binding of dielectric materials on the conductive surface. Furthermore, the type of monoclonal antibody used to craft the BioS and the artificial receptors led to very distinct responses, being the RBD5305 and the NanoMIP-based BioS the ones that showcased the highest increment of signal in the conditions herein reported, which suggests their adequacy in the development of impedimetric immunosensors for SARS-CoV-2 spike glycoprotein.
3
Citation4
1
Save
0

Fifteen-year recall period on zirconia-based single crowns and fixed dental prostheses. A prospective observational study

Shahnawaz Khijmatgar et al.Jun 20, 2024
Abstract Aim The aim of this study was to evaluate the long-term clinical outcomes of zirconia-based prostheses used for tooth-supported or implant-supported single crowns and fixed dental prostheses (FPD). Methods The authors conducted a prospective analysis of 562 zirconia core restorations supported by endodontically treated teeth or titanium implant in 276 patients in a general dental private practice, with a follow-up period of 15 years. The study was stopped after patients achieved 15 yrs of follow-up. The study analyzed the failure and complication rates of single and multiple crowns, based on Kaplan Meier analysis. Results During follow-up period, there were 26 complications and 156 failures. The crown level analysis revealed a cumulative failure rate of 28.33% and complication rate of 8.47% for zirconia crowns after 15 years. The complication rate was found to be higher for titanium implant-supported than for natural teeth-supported crowns. The different types of crown-based failure include: veener fracture 5.01% ( N = 29), metal zirconia led to 14.85% ( N = 86) loss of retention, and 1.73% ( N = 10) loss of crown due to extraction. Conclusion Based on these findings, zirconia core restorations appear to be a reliable long-term solution for crowns and fixed dental prostheses. Clinical relevance The study suggests that zirconia restorations can be successfully used for long-term prostheses on natural teeth or implants supported. The study results provide clinicians valuable information when selecting prosthetic restorations material.
0
Citation2
0
Save
0

Detection and sensing of oral xenobiotics in edentulous patients rehabilitated with titanium dental implants: Insights from a scoping review

Pier Poli et al.Jul 1, 2023
Titanium has been considered the standard element in implant manufacturing. Recent studies have evaluated the role of titanium as a biological modulator of oral health. However, evidence regarding the association between the release of metal particles and peri-implantitis is lacking.The purpose of this scoping review was to evaluate the literature regarding the release of metal particles in peri-implant tissues correlated with the methods of detection and the local and systemic implications.The study was performed in adherence with the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines and was registered with the National Institute for Health Research PROSPERO (Submission No. 275576; ID: CRD42021275576). A systematic search was conducted in the Cochrane Central Register of Controlled Trials, EMBASE, MEDLINE via PubMed, Scopus, and Web of Science bibliographic databases, complemented by a manual evaluation. Only in vivo human studies written in the English language and published between January 2000 and June 2022 were included.In total, 10 studies were included according to eligibility criteria. Different tissues and analytic techniques were reported: the characterization technique most used was inductively coupled plasma mass spectrometry. All 10 studies analyzed the release of metal particles in patients with dental implants, continuously detecting titanium. None of the studies reported a significant association between metal particles and biological effects.Titanium is still considered the material of choice in implant dentistry, despite the detection of metal particles in peri-implant tissues. Further studies are necessary to evaluate the association between analytes and local health or inflammatory status.
0
Citation2
0
Save
0

Single-Nucleotide Polymorphisms in WNT Genes in Patients with Non-Syndromic Orofacial Clefts in a Polish Population

Alicja Zawiślak et al.Jul 17, 2024
Non-syndromic orofacial cleft (OFC) is the most common facial developmental defect in the global population. The etiology of these birth defects is complex and multifactorial, involving both genetic and environmental factors. This study aimed to determine if SNPs in the WNT gene family (rs1533767, rs708111, rs3809857, rs7207916, rs12452064) are associated with OFCs in a Polish population. The study included 627 individuals: 209 children with OFCs and 418 healthy controls. DNA was extracted from saliva for the study group and from umbilical cord blood for the control group. Polymorphism genotyping was conducted using quantitative PCR. No statistically significant association was found between four variants and clefts, with odds ratios for rs708111 being 1.13 (CC genotype) and 0.99 (CT genotype), for rs3809857 being 1.05 (GT genotype) and 0.95 (TT genotype), for rs7207916 being 0.86 (AA genotype) and 1.29 (AG genotype) and for rs12452064 being 0.97 (AA genotype) and 1.24 (AG genotype). However, the rs1533767 polymorphism in WNT showed a statistically significant increase in OFC risk for the GG genotype (OR = 1.76, p < 0.001). This research shows that the rs1533767 polymorphism in the WNT gene is an important risk marker for OFC in the Polish population.
0
Citation1
0
Save
Load More