GB
Guillaume Bouchoux
Author with expertise in Focused Ultrasound Technology and Applications
Achievements
Open Access Advocate
Cited Author
Key Stats
Upvotes received:
0
Publications:
2
(100% Open Access)
Cited by:
281
h-index:
18
/
i10-index:
24
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Safety and Feasibility of Repeated and Transient Blood–Brain Barrier Disruption by Pulsed Ultrasound in Patients with Recurrent Glioblastoma

Ahmed Idbaïh et al.Mar 19, 2019
The blood-brain barrier (BBB) limits the efficacy of drug therapies for glioblastoma (GBM). Preclinical data indicate that low-intensity pulsed ultrasound (LIPU) can transiently disrupt the BBB and increase intracerebral drug concentrations.A first-in-man, single-arm, single-center trial (NCT02253212) was initiated to investigate the transient disruption of the BBB in patients with recurrent GBM. Patients were implanted with a 1-MHz, 11.5-mm diameter cranial ultrasound device (SonoCloud-1, CarThera). The device was activated monthly to transiently disrupt the BBB before intravenous carboplatin chemotherapy.Between 2014 and 2016, 21 patients were registered for the study and implanted with the SonoCloud-1; 19 patients received at least one sonication. In 65 ultrasound sessions, BBB disruption was visible on T1w MRI for 52 sonications. Treatment-related adverse events observed were transient and manageable: a transient edema at H1 and at D15. No carboplatin-related neurotoxicity was observed. Patients with no or poor BBB disruption (n = 8) visible on MRI had a median progression-free survival (PFS) of 2.73 months, and a median overall survival (OS) of 8.64 months. Patients with clear BBB disruption (n = 11) had a median PFS of 4.11 months, and a median OS of 12.94 months.SonoCloud-1 treatments were well tolerated and may increase the effectiveness of systemic drug therapies, such as carboplatin, in the brain without inducing neurotoxicity.See related commentary by Sonabend and Stupp, p. 3750.
0
Citation277
0
Save
0

Ultrasound-mediated delivery of doxorubicin to the brain results in immune modulation and improved responses to PD-1 blockade in gliomas

Víctor Arrieta et al.Jun 6, 2024
Abstract Given the marginal penetration of most drugs across the blood-brain barrier, the efficacy of various agents remains limited for glioblastoma (GBM). Here we employ low-intensity pulsed ultrasound (LIPU) and intravenously administered microbubbles (MB) to open the blood-brain barrier and increase the concentration of liposomal doxorubicin and PD-1 blocking antibodies (aPD-1). We report results on a cohort of 4 GBM patients and preclinical models treated with this approach. LIPU/MB increases the concentration of doxorubicin by 2-fold and 3.9-fold in the human and murine brains two days after sonication, respectively. Similarly, LIPU/MB-mediated blood-brain barrier disruption leads to a 6-fold and a 2-fold increase in aPD-1 concentrations in murine brains and peritumoral brain regions from GBM patients treated with pembrolizumab, respectively. Doxorubicin and aPD-1 delivered with LIPU/MB upregulate major histocompatibility complex (MHC) class I and II in tumor cells. Increased brain concentrations of doxorubicin achieved by LIPU/MB elicit IFN-γ and MHC class I expression in microglia and macrophages. Doxorubicin and aPD-1 delivered with LIPU/MB results in the long-term survival of most glioma-bearing mice, which rely on myeloid cells and lymphocytes for their efficacy. Overall, this translational study supports the utility of LIPU/MB to potentiate the antitumoral activities of doxorubicin and aPD-1 for GBM.
0
Citation4
0
Save