WF
Wei Fan
Author with expertise in Applications of Ionic Liquids
Achievements
Cited Author
Key Stats
Upvotes received:
0
Publications:
11
(36% Open Access)
Cited by:
945
h-index:
24
/
i10-index:
63
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Dual Amino‐Functionalised Phosphonium Ionic Liquids for CO2 Capture

Yanqiang Zhang et al.Feb 2, 2009
A series of 20 dual amino-functionalised phosphonium ionic liquids, (3-aminopropyl)tributylphosphonium amino acid salts ([aP(4443)][AA], in which [AA](-) = [Ala](-), [Arg](-), [Asn](-), [Asp](-), [Cys](-), [Gln](-), [Glu](-), [Gly](-), [His](-), [Ile](-), [Leu](-), [Lys](-), [Met](-), [Phe](-), [Pro](-), [Ser](-), [Thr](-), [Trp](-), [Tyr](-) and [Val](-)), has been prepared. Their physicochemical properties, such as density, viscosity, glass transition and thermal decomposition temperatures and conductivity, have been determined. In particular, the [aP(4443)][AA] ionic liquids (ILs) have low glass transition temperatures ranging from -69.7 to -29.6 degrees C and high decomposition temperatures (all above 200 degrees C). The effects of the variation of the structure of [AA](-) on the above physicochemical properties are discussed. Furthermore, the CO(2) absorption of [aP(4443)][Gly], [aP(4443)][Ala], [aP(4443)][Val] and [aP(4443)][Leu], taken as examples, was investigated. It was found that the supported absorption of CO(2) by the [aP(4443)][AA] ILs almost reaches equilibrium within 80 min, the chemical absorption of CO(2) by the [aP(4443)][AA] ILs approaches 1 mol CO(2) per mol ionic liquid (twice that reported before) and the [aP(4443)][AA] ILs can be repeatedly recycled for CO(2) uptake.
0

Effect of 3D printed teeth and virtual simulation system on the pre-clinical access cavity preparation training of senior dental undergraduates

Mengting Duan et al.Aug 23, 2024
The objective of the present study was to evaluate the effect of 3D printed teeth and virtual simulation system on the pre-clinical access cavity preparation training of senior dental undergraduates. The 3D printed teeth were manufactured based on the micro-CT data of an extracted lower first molar. Ninety-eight senior dental undergraduate students were required to finish the access cavity preparation of lower first molar within 20 min on plastic and 3D printed teeth on the manikin system as well as on a virtual simulation machine respectively with randomly selected sequences. Expert dentists scored the operated teeth. The scores from the virtual simulation system were also recorded. All the scores were analyzed and compared. Following the procedure, two questionnaires were sent to students to further evaluate the feelings and optimal training sequence. No significant differences were found between plastic and 3D printed teeth scores, while virtual simulation achieved a valid/invalid area removal ratio of 96.86% ± 5.08% and 3.97% ± 1.85%, respectively. Most students found plastic teeth training the easiest and favored the three-training combination (36.36%). 71.42% of the students thought the virtual simulation training should be put at the first place of the three trainings. Over 80% of students agreed with incorporating 3D printed teeth and virtual simulation into their routine training courses. In addition, the general advantages and disadvantages of the virtual simulation system and 3D printed teeth training received almost equal recognition by students. Virtual simulation system training + plastic teeth training + 3D printed teeth training might be the optimal training sequence. Virtual simulation system training could not completely replace the traditional training methods on the manikin system at the moment. With further modifications, 3D printed teeth could be expected to replace the plastic teeth for the pre-clinical access cavity preparation training.
0

In situ interfacial evaluation of aramid/epoxy composites by interfacial stress transfer characteristics

Zhicheng Wu et al.Jul 1, 2024
Interfacial bonding between aramid fibers and epoxy resin is crucial for the mechanical properties of fiber-reinforced epoxy composites. Interfacial stress transfer between resin and fibers bridges microscopic and macroscopic properties. Using micro-Raman spectroscopy for in situ stress measurement offers insights into interface bonding through assessment of interfacial stress transfer characteristics. This study measures stress distribution on loaded microdroplet sample surfaces, analyzes stress transfer at the interface, and proposes an evaluation method using finite element analysis (FEA). The results show that interfacial stress along the fiber decreases from the droplet's edge to center, indicating stress transfer between the fiber and matrix, as evidenced by the stress-dependent Raman shift of aramid fiber. The interface modulus (Eif), derived from the FEA model, effectively reflects interface bonding, with droplet shape influence removed in evaluations. The agreement between the proposed method and the transverse fiber bundle test confirms its applicability. The method offers a direct, non-destructive, and shape-independent way to evaluate the interface of aramid/epoxy composites.
Load More