MA
M.A. Ali
Author with expertise in Electrochemical Detection of Heavy Metal Ions
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
4
(75% Open Access)
Cited by:
1
h-index:
11
/
i10-index:
12
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Eco-friendly optical sensor for precise detection of gold ions in diverse matrices through the integration of β-2-hydroxybenzyl-3-methoxy-2-hydroxyazastyrene in a PVC membrane

Mohamed Hemdan et al.May 29, 2024
Abstract An environmentally conscious methodology is investigated for the precise and discerning identification of trace concentrations of gold ions in diverse matrices. A novel optical sensor membrane is proposed for the determination of Au 3+ ions, utilizing the immobilization of β-2-hydroxybenzyl-3-methoxy-2-hydroxyazastyrene (HMHS) entrapped in polyvinyl chloride (PVC). The sensor incorporates sodium tetraphenylborate (Na-TPB) as the ionic additive and dibutyl phthalate (DBP) as a plasticizer. Under optimal conditions, the suggested sensor exhibits a linear calibration response to Au 3+ ions within a concentration range of 5.0 to 165 ng mL −1 . Detection and quantification limits are specified as 1.5 and 4.8 ng mL −1 , respectively, with a rapid response time of 5.0 min. Upon presentation, this optical sensor not only affirms high reproducibility, stability, and an extended operational lifespan but also showcases exceptional selectivity for Au 3+ ions. Notably, no discernible interference is observed when assessing the potential influence of other cations and anions on Au 3+ ion detection. The adaptability of this optical sensor is validated through its successful application in determining Au 3+ ion concentrations across various sample types, including water, environmental, cosmetics, and soil matrices. Graphical Abstract
0
Citation1
0
Save
0

Normal Echocardiographic Parameters in Egyptian Nubian Goats

M.A. Ali et al.Aug 7, 2024
The reference parameters for echocardiography are poorly documented in goats and undocumented in Egyptian Nubian goats. This study aimed to establish reference ranges for echocardiographic indices using M-mode and Doppler techniques in Egyptian Nubian goats. Echocardiographic parameters were measured in 25 healthy Egyptian goats aged 3 to 4 years, weighing 40-50 kg, in lateral recumbency position. The parameters included left ventricular end-systolic and end-diastolic diameters, interventricular septum thickness in systole and diastole, left ventricular free wall thickness in systole and diastole, heart rate, final diastolic volume, final systolic volume, cardiac output, stroke volume, fractional shortening, and ejection fraction. Additionally, aortic root diameter, left atrial diameter, and the left atrial-to-aortic root ratio were reported. Doppler echocardiography was used to assess blood flow velocities in the pulmonary artery and aorta: peak velocity and pressure gradient. Parameters of left ventricular diastolic function, including early (Emax) and late (Amax) velocities, and the Emax/Amax ratio, were obtained from the mitral flow profile. Several differences in echocardiographic dimensions were found in Egyptian goats compared to previous studies in other goat breeds. In conclusion, echocardiographic parameters can be reliably evaluated in Egyptian goats, and our study has provided normal reference ranges that may be useful in accurately assessing cardiac structures and functions to aid in diagnosing heart diseases. These findings can also benefit experimental studies on the heart and blood vessels in goats used for human research purposes.