LW
Lian‐Ming Wu
Author with expertise in Diagnosis and Management of Arrhythmogenic Right Ventricular Cardiomyopathy
Achievements
This user has not unlocked any achievements yet.
Key Stats
Upvotes received:
0
Publications:
7
(43% Open Access)
Cited by:
2
h-index:
26
/
i10-index:
46
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Coronary Artery Wall Contrast Enhancement Imaging Impact on Disease Activity Assessment in IgG4-RD a direct marker of coronary involvement

Yaqi Du et al.Jan 1, 2024
Coronary artery wall contrast enhancement (CE) has been applied to non-invasive visualization of changes to the coronary artery wall in systemic lupus erythematosus (SLE). This study investigated the feasibility of quantifying CE to detect coronary involvement in IgG4-related disease (IgG4-RD), as well as the influence on disease activity assessment. A total of 93 subjects (31 IgG4-RD; 29 SLE; 33 controls) were recruited in the study. Coronary artery wall imaging was performed in a 3.0 T MRI scanner. Serological markers and IgG4-RD Responder Index (IgG4-RD-RI) scores were collected for correlation analysis. Coronary wall CE was observed in 29 (94%) IgG4-RD patients and 22 (76%) SLE patients. Contrast-to-noise ratio (CNR) and total CE area were significantly higher in patient groups compared to controls (CNR: 6.1 ± 2.7 [IgG4-RD] v. 4.2 ± 2.3 [SLE] v. 1.9 ± 1.5 [control], P < 0.001; Total CE area: 3.0 [3.0-6.6] v. 1.7 [1.5-2.6] v. 0.3 [0.3-0.9], P < 0.001). In the IgG4-RD group, CNR and total CE area were correlated with the RI (CNR: r =0.55, P =0.002; total CE area: r = 0.39, P = 0.031). RI´ scored considering coronary involvement by CE, differed significantly from RI scored without consideration of CE (RI v. RI´: 15 ± 6 v. 16 ± 6, P < 0.001). Visualization and quantification of CMR coronary CE by CNR and total CE area could be utilized to detect subclinical and clinical coronary wall involvement, which is prevalent in IgG4-RD. The potential inclusion of small and medium-sized vessel involvements in the assessment of disease activity in IgG4-RD is worthy of further investigation.
0

Deep learning-driven pulmonary arteries and veins segmentation reveals demography-associated pulmonary vasculature anatomy

Yuetan Chu et al.Apr 11, 2024
Pulmonary artery-vein segmentation is crucial for diagnosing pulmonary diseases and surgical planning, and is traditionally achieved by Computed Tomography Pulmonary Angiography (CTPA). However, concerns regarding adverse health effects from contrast agents used in CTPA have constrained its clinical utility. In contrast, identifying arteries and veins using non-contrast CT, a conventional and low-cost clinical examination routine, has long been considered impossible. Here we propose a High-abundant Pulmonary Artery-vein Segmentation (HiPaS) framework achieving accurate artery-vein segmentation on both non-contrast CT and CTPA across various spatial resolutions. HiPaS first performs spatial normalization on raw CT scans via a super-resolution module, and then iteratively achieves segmentation results at different branch levels by utilizing the low-level vessel segmentation as a prior for high-level vessel segmentation. We trained and validated HiPaS on our established multi-centric dataset comprising 1,073 CT volumes with meticulous manual annotation. Both quantitative experiments and clinical evaluation demonstrated the superior performance of HiPaS, achieving a dice score of 91.8% and a sensitivity of 98.0%. Further experiments demonstrated the non-inferiority of HiPaS segmentation on non-contrast CT compared to segmentation on CTPA. Employing HiPaS, we have conducted an anatomical study of pulmonary vasculature on 10,613 participants in China (five sites), discovering a new association between pulmonary vessel abundance and sex and age: vessel abundance is significantly higher in females than in males, and slightly decreases with age, under the controlling of lung volumes (p < 0.0001). HiPaS realizing accurate artery-vein segmentation delineates a promising avenue for clinical diagnosis and understanding pulmonary physiology in a non-invasive manner.
0

Ligand-Induced Atomically Segregation-Tunable Alloy Nanoprobes for Enhanced Magnetic Resonance Imaging

Zeyu Liang et al.May 31, 2024
Bimetallic iron-noble metal alloy nanoparticles have emerged as promising contrast agents for magnetic resonance imaging (MRI) due to their biocompatibility and facile control over the element distribution. However, the inherent surface energy discrepancy between iron and noble metal often leads to Fe atom segregation within the nanoparticle, resulting in limited iron–water molecule interactions and, consequently, diminished relaxometric performance. In this study, we present the development of a class of ligand-induced atomically segregation-tunable alloy nanoprobes (STAN) composed of bimetallic iron–gold nanoparticles. By manipulating the oxidation state of Fe on the particle surface through varying molar ratios of oleic acid and oleylamine ligands, we successfully achieve surface Fe enrichment. Under the application of a 9 T MRI system, the optimized STAN formulation, characterized by a surface Fe content of 60.1 at %, exhibits an impressive r1 value of 2.28 mM–1·s–1, along with a low r2/r1 ratio of 6.2. This exceptional performance allows for the clear visualization of hepatic tumors as small as 0.7 mm in diameter in vivo, highlighting the immense potential of STAN as a next-generation contrast agent for highly sensitive MR imaging.
0

Fractal analysis of left ventricular trabeculae in heart failure with preserved ejection fraction patients with multivessel coronary artery disease

Zhengqin Gu et al.Jun 18, 2024
Abstract Objectives Endocardial trabeculae undergo varicose changes and hyperplasia in response to hemodynamic influences and are a variable phenotype reflecting changes in disease. Fractal analysis has been used to analyze the complexity of endocardial trabeculae in a variety of cardiomyopathies. The aim of this paper was to quantify the myocardial trabecular complexity through fractal analysis and to investigate its predictive value for the diagnosis of heart failure with preserved ejection fraction (HFpEF) in patients with multivessel coronary artery disease (CAD). Methods The retrospective study population consisted of 97 patients with multivessel CAD, 39 of them were diagnosed with HFpEF, while 46 healthy volunteers were recruited as controls. Fractal dimension (FD) was obtained through fractal analysis of endocardial trabeculae on LV short-axis cine images. Logistic regression analyses were used to confirm the predictors and compare different prediction models. Results Mean basal FD was significantly higher in patients with HFpEF than in patients without HFpEF or in the healthy group (median: 1.289; IQR: 0.078; p < 0.05). Mean basal FD was also a significant independent predictor in univariate and multivariate logistic regression (OR: 1.107 and 1.043, p < 0.05). Furthermore, adding FD to the prediction model improved the calibration and accuracy of the model (c-index: 0.806). Conclusion The left ventricular FD obtained with fractal analysis can reflect the complexity of myocardial trabeculae and has an independent predictive value for the diagnosis of HFpEF in patients with multivessel CAD. Including FD into the diagnostic model can help improve the diagnosis. Critical relevance statement Differences show in the complexity of endocardial trabeculae in multivessel coronary artery disease patients, and obtaining fractal dimensions (FD) by fractal analysis can help identify heart failure with preserved ejection fraction (HFpEF) patients. Key Points The complexity of myocardial trabeculae differs among patients with multivessel coronary artery disease. Left ventricular fractal dimensions can reflect the complexity of the myocardial trabecular. Fractal dimensions have predictive value for the diagnosis of heart failure with preserved ejection fraction. Graphical Abstract