BD
B. Ding
Author with expertise in Particle Physics and High-Energy Collider Experiments
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
20
(80% Open Access)
Cited by:
3
h-index:
2
/
i10-index:
0
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Measurement of the cross sections of $$ {e}^{+}{e}^{-}\to {K}^{-}{\overline{\Xi}}^{+}\Lambda /{\Sigma}^0 $$ at center-of-mass energies between 3.510 and 4.914 GeV

Wei Wang et al.Jul 26, 2024
A bstract Using e + e − collision data collected with the BESIII detector at the BEPCII collider at center-of-mass energies between 3.510 and 4.914 GeV, corresponding to an integrated luminosity of 25 fb − 1 , we measure the Born cross sections for the process $$ {e}^{+}{e}^{-}\to {K}^{-}{\overline{\Xi}}^{+}\Lambda /{\Sigma}^0 $$  e +   e −  →  K −   Ξ ¯ +  Λ /  Σ 0  at thirty-five energy points with a partial-reconstruction strategy. By fitting the dressed cross sections of $$ {e}^{+}{e}^{-}\to {K}^{-}{\overline{\Xi}}^{+}\Lambda /{\Sigma}^0 $$  e +   e −  →  K −   Ξ ¯ +  Λ /  Σ 0  , evidence for $$ \psi (4160)\to {K}^{-}{\overline{\Xi}}^{+}\Lambda $$ ψ  4160  →  K −   Ξ ¯ +  Λ is found for the first time with a significance of 4.4 σ , including systematic uncertainties. No evidence for other possible resonances is found. In addition, the products of electronic partial width and branching fraction for all assumed resonances decaying into $$ {K}^{-}{\overline{\Xi}}^{+}\Lambda /{\Sigma}^0 $$  K −   Ξ ¯ +  Λ /  Σ 0  are determined.
0

A continuous hemodynamic parameters algorithm based on the wearable tonometric device

Jiayuan Fang et al.Mar 2, 2024
This study introduces a pioneering approach to managing hypertension and preventing catastrophic cardiovascular events through a novel continuous hemodynamics algorithm, integrated within a wearable tonometric device (WTD). This advanced algorithm leverages mathematical analysis of arterial pressure (AP) waveforms, accurately calculating key hemodynamic parameters such as systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP), and heart rate (HR). These calculations are performed in real time by identifying feature points in AP waveforms and extracting vital parameters through pulse wave analysis (PWA). The algorithm incorporates pre-input biometric data to create a data vector, which is then processed using a multiple non-linear regression model to compute beat-to-beat Cardiac output (CO). Additional hemodynamic parameters are derived by analyzing pulse waveforms in conjunction with CO values, ensuring a comprehensive hemodynamic profile. The efficacy and precision of this algorithm are validated against commercial medical-grade devices and the WTD system through human trials, demonstrating medical-grade accuracy. The results affirm the stability, reliability, and accuracy of the hemodynamic parameters algorithm, highlighting the WTD's potential as a transformative solution in wearable health technology. By providing real-time, medical-grade monitoring in a wearable format, the WTD device is set to revolutionize remote patient-centered healthcare, offering a proactive approach to monitoring and managing cardiovascular health.
0

Study of η′ → π+π−l+l− decays at BESIII

J. Bennett et al.Jul 16, 2024
A bstract With a sample of (10087 ± 44) × 10 6 J/ψ events accumulated with the BESIII detector, we analyze the decays η ′ → π + π − l + l − ( l = e, μ ) via the process J/ψ → γη ′. The branching fractions are measured to be $$ \mathcal{B} $$ B ( η ′ → π + π − e + e − ) = (2 . 45 ± 0 . 02(stat . ) ± 0 . 08(syst . )) × 10 − 3 and $$ \mathcal{B} $$ B ( η ′ → π + π − μ + μ − ) = (2 . 16 ± 0 . 12(stat . ) ± 0 . 06(syst . )) × 10 − 5 , and the ratio is $$ \frac{\mathcal{B}\left({\eta}^{\prime}\to {\pi}^{+}{\pi}^{-}{e}^{+}{e}^{-}\right)}{\mathcal{B}\left({\eta}^{\prime}\to {\pi}^{+}{\pi}^{-}{\mu}^{+}{\mu}^{-}\right)}=113.4\pm 0.9\left(\textrm{stat}.\right)\pm 3.7\left(\textrm{syst}.\right) $$  B   η ′  →  π +   π −   e +   e −   B   η ′  →  π +   π −   μ +   μ −    = 113.4 ± 0.9  stat .  ± 3.7  syst .  . In addition, by combining the η ′ → π + π − e + e − and η ′ → π + π − μ + μ − decays, the slope parameter of the electromagnetic transition form factor is measured to be b η ′ = 1.30 ± 0.19 (GeV /c 2 ) − 2 , which is consistent with previous measurements from BESIII and theoretical predictions from the VMD model. The asymmetry in the angle between the π + π − and l + l − decay planes, which has the potential to reveal the CP -violation originating from an unconventional electric dipole transition, is also investigated. The asymmetry parameters are determined to be $$ {\mathcal{A}}_{CP}\left({\eta}^{\prime}\to {\pi}^{+}{\pi}^{-}{e}^{+}{e}^{-}\right)=\left(-0.21\pm 0.73\left(\textrm{stat}.\right)\pm 0.01\left(\textrm{syst}.\right)\right)\% $$ A CP   η ′  →  π +   π −   e +   e −   =  − 0.21 ± 0.73  stat .  ± 0.01  syst .   % and $$ {\mathcal{A}}_{CP}\left({\eta}^{\prime}\to {\pi}^{+}{\pi}^{-}{\mu}^{+}{\mu}^{-}\right)=\left(0.62\pm 4.71\left(\textrm{stat}.\right)\pm 0.08\left(\textrm{syst}.\right)\right)\% $$ A CP   η ′  →  π +   π −   μ +   μ −   =  0.62 ± 4.71  stat .  ± 0.08  syst .   % , implying that no evidence of CP -violation is observed at the present statistics. Finally, an axion-like particle is searched for via the decay η ′ → π + π − a, a → e + e − , and upper limits of the branching fractions are presented for the mass assumptions of the axion-like particle in the range of 0 − 500 MeV /c 2 .
Load More