SL
Sonia Leva
Author with expertise in Photovoltaic Maximum Power Point Tracking Techniques
Achievements
Cited Author
Key Stats
Upvotes received:
0
Publications:
21
(38% Open Access)
Cited by:
1,921
h-index:
42
/
i10-index:
121
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Comparison of different physical models for PV power output prediction

Alberto Dolara et al.Jul 9, 2015
The electricity produced from renewable energy, in particular from wind and photovoltaic plants, has seen exponential rise in the last decade. Consequently, the prediction of power produced from these plants is fundamental for the reliability, safety and stability of the grid. This paper compares three physical models describing the PV cell (corresponding to three-, four- and five-parameter equivalent electric circuit) and two thermal models for the cell temperature estimation (NOCT and Sandia). The models were calibrated and tested towards ten monocrystalline and eight polycrystalline modules installed at SolarTechLab at Politecnico di Milano. The hourly error of the forecasted power output is usually lower than 15 Wh, while NMAE% and WMAE% are in the range of 0.5% and 10%. Low errors, calculated with actual weather conditions, suggest that the implemented models are accurate, but they cannot be directly compared with other approaches which adopt weather forecasts. Results show that there is no clear advantage of using complex models, but the data used for the model calibration mostly affect the model accuracy. It was found that forecasted power output are more accurate using experimental data and Sandia’s thermal model in monocrystalline cells type, while for the polycrystalline the data from the manufacturer and NOCT have lower errors.
0

Day-Ahead Photovoltaic Forecasting: A Comparison of the Most Effective Techniques

Alfredo Nespoli et al.Apr 29, 2019
We compare the 24-hour ahead forecasting performance of two methods commonly used for the prediction of the power output of photovoltaic systems. Both methods are based on Artificial Neural Networks (ANN), which have been trained on the same dataset, thus enabling a much-needed homogeneous comparison currently lacking in the available literature. The dataset consists of an hourly series of simultaneous climatic and PV system parameters covering an entire year, and has been clustered to distinguish sunny from cloudy days and separately train the ANN. One forecasting method feeds only on the available dataset, while the other is a hybrid method as it relies upon the daily weather forecast. For sunny days, the first method shows a very good and stable prediction performance, with an almost constant Normalized Mean Absolute Error, NMAE%, in all cases (1% < NMAE% < 2%); the hybrid method shows an even better performance (NMAE% < 1%) for two of the days considered in this analysis, but overall a less stable performance (NMAE% > 2% and up to 5.3% for all the other cases). For cloudy days, the forecasting performance of both methods typically drops; the performance is rather stable for the method that does not use weather forecasts, while for the hybrid method it varies significantly for the days considered in the analysis.
0

Light Unmanned Aerial Vehicles (UAVs) for Cooperative Inspection of PV Plants

P. Quater et al.Jun 18, 2014
After a fast photovoltaic (PV) expansion in the past decade supported by many governments in Europe, in this postincentive era, one of the most significant open issues in the PV sector is to find appropriate inspection methods to evaluate real PV plant performance and failures. In this context, PV modules are surely the key components affecting the overall system performance; therefore, there is a main concern about the occurrence of any kind of failure in PV modules. This paper aims to propose a novel concept for monitoring PV plants by using light unmanned aerial vehicles (UAVs) or systems (UASs) during their operation and maintenance. The main objectives of this study are to explore and evaluate the use of different UAV technologies and to propose a reliable, cost-effective, and time-saving method for the inspection of PV plants. In this research, different UAVs were employed to inspect a PV array field. For this purpose, some thermal imaging cameras and a visual camera were chosen as monitoring tools to suitably scan PV modules. The first results show that the procedure of utilizing UAV was effective in the detection of different failures of PV modules. Moreover, such a process was much faster and cost effective than traditional methods.
0

Comparative study of machine learning techniques for the state of health estimation of Li-Ion batteries

Panagiotis Eleftheriadis et al.Jul 17, 2024
Lithium-Ion batteries play a crucial role in vehicle electrification to meet the goals of reducing fossil fuels. However, they deteriorate over time and it is thus needed to predict their rate of decay since, after a certain threshold, they are not suitable anymore for their designed application. One of the main indicators that displays the aging status of a cell is the State of Health (SOH), which expresses the remaining total capacity of the cell in comparison with its initial total capacity. For an accurate evaluation of the SOH, various methods have been proposed in the literature. In this article, a comparative study of nine data-driven techniques in terms of error and processing time is presented. These different algorithms have been tested on two public datasets, extracting selected features and performing an Incremental Capacity Analysis (ICA) to estimate the SOH of a cell using only partial discharges. The benefits of using Machine Learning (ML) methods for the models can be found in the processing times that are faster than experimental methods, making the entire industrial testing stage faster.
0

Outdoor Performance Comparison of Bifacial and Monofacial Photovoltaic Modules in Temperate Climate and Industrial-like Rooftops

Alejandro González-Moreno et al.Jun 29, 2024
To fully exploit the advantages of bifacial PV (bPV) modules and understand their performance under real-world conditions, a comprehensive investigation was conducted. It was focused on bPV installations with some mounting constraints, as in industrial rooftops, where the ideal high module-to-ground height for optimal bPV performances is not feasible due to structural reasons. The experimental setup involved measuring the I-V curves of conventional and bifacial modules under diverse atmospheric conditions, including different solar irradiance levels and ambient temperatures, as well as mounting configurations. The results show a proportional increment of power generation between 4.3% and 7.8% if compared with two different conventional modules and a bifacial power gain between 2 and 15% under identical conditions. Additionally, the negative potential influence of the mounting structure was observed. Small differences in the alignment between the module and structural beams can virtually eliminate the bifacial contribution, with an estimated reduction up to 8.5 W (a potential bifacial gain of 3.43%).
Load More