SN
Shady Nakhla
Author with expertise in Catheter Ablation of Cardiac Arrhythmias
Achievements
This user has not unlocked any achievements yet.
Key Stats
Upvotes received:
0
Publications:
8
(38% Open Access)
Cited by:
4
h-index:
6
/
i10-index:
4
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Comparative Efficacy and Safety of Pulsed Field Ablation Versus Radiofrequency Ablation of Idiopathic LV Arrhythmias

Arwa Younis et al.Jun 1, 2024
Comparative efficacy and safety data on radiofrequency ablation (RFA) versus pulsed field ablation (PFA) for common idiopathic left ventricular arrhythmia (LV-VAs) locations are lacking. This study sough to compare RFA with PFA of common idiopathic LV-VAs locations. Ten swine were randomized to PFA or RFA of LV interventricular septum, papillary muscle, LV summit via distal coronary sinus, and LV epicardium via subxiphoid approach. Ablations were delivered using an investigational dual-energy (RFA/PFA) contact force (CF) and local impedance-sensing catheter. After 1-week survival, animals were euthanized for lesion assessment. A total of 55 PFA (4 applications/site of 2.0 KV, target CF ≥10 g) and 36 RFA (CF ≥10 g, 25–50 W targeting ≥50 Ω local impedance drop, 60-second duration) were performed. LV interventricular septum: average PFA depth 7.8 mm vs RFA 7.9 mm (P = 0.78) and no adverse events. Papillary muscle: average PFA depth 8.1 mm vs RFA 4.5 mm (P < 0.01). Left ventricular summit: average PFA depth 5.6 mm vs RFA 2.7 mm (P < 0.01). Steam-pop and/or ventricular fibrillation in 4 of 12 RFA vs 0 of 12 PFA (P < 0.01), no ST-segment changes observed. Epicardium: average PFA depth 6.4 mm vs RFA 3.3 mm (P < 0.01). Transient ST-segment elevations/depressions occurred in 4 of 5 swine in the PFA arm vs 0 of 5 in the RFA arm (P < 0.01). Angiography acutely and at 7 days showed normal coronaries in all cases. In this swine study, compared with RFA, PFA of common idiopathic LV-VAs locations produced deeper lesions with fewer steam pops. However, PFA was associated with higher rates of transient ST-segment elevations and depressions with direct epicardium ablation.
0
Citation2
0
Save
0

Left Atrial Appendage Occlusion: Expanding Indications and New Developments

Grant Reed et al.Aug 1, 2024
Percutaneous left atrial appendage occlusion (LAAO) is recommended in several major international society guidelines as a viable alternative to therapeutic anticoagulation for the prevention of ischemic stroke in patients with nonvalvular atrial fibrillation or flutter. Recent innovations in device development have improved the safety and procedural success of LAAO, further fueling enthusiasm for expanding its indications beyond patients with high-bleeding risk from oral anticoagulation use. It is the aim of this review to provide historical context in addition to recent updates and upcoming developments and provide practical suggestions on how best to care for patients who are candidates for LAAO in contemporary practice. Recent data comparing the safety and efficacy of post-LAAO antiplatelet vs. antithrombotic therapy will be highlighted, with specific recommendations regarding which patients are best suited for each strategy. We will also address the safety and practical considerations provided by emerging trials on concomitant LAAO during other structural heart interventions such as transcatheter aortic valve replacement and mitral valve interventions, as well as electrophysiology procedures including catheter ablation for atrial fibrillation and pacemaker implantation. Practical considerations for the use of transesophageal echocardiography or intracardiac echocardiography for procedural guidance will also be discussed. As the evidence supporting LAAO continues to evolve, this review will serve as a primer on the recent and upcoming advances in device technology and management strategies positioned to further push LAAO forward into the future.
0

Outcomes of Atrial Fibrillation Ablation in Heart Failure Subtypes

Arwa Younis et al.Aug 28, 2024
BACKGROUND: Catheter ablation (CA) improves clinical outcomes in patients with atrial fibrillation (AF) and heart failure (HF) with reduced ejection fraction (HFrEF). We aimed to evaluate the impact of CA on clinical and quality-of-life outcomes across HF subtypes. METHODS: All patients undergoing AF ablation at a tertiary center were enrolled in a prospective registry and included in this study (2013–2021). The primary end point was AF recurrence. Secondary end points included AF-related hospitalizations and quality-of-life outcomes. Patients were categorized according to their HF status: no HF, HFrEF, HF with mildly reduced ejection fraction (HFmrEF), and HF with preserved ejection fraction (HFpEF). RESULTS: 7020 patients were included (80% no HF, 8% HFrEF, 7% HFmrEF, and 5% HFpEF). Over 3 years, the cumulative incidence of AF recurrence after ablation was as follows: HFpEF (53%), HFmrEF (41%), HFrEF (41%), and no HF (34%); P <0.01. Multivariable Cox analyses confirmed these findings using no HF group as reference (HFpEF: hazard ratio, 1.47 [95% CI, 1.21–1.78]; HFmrEF: hazard ratio, 1.23 [95% CI, 1.04–1.45]; and HFrEF: hazard ratio, 1.17 [95% CI, 1.01–1.37]; P <0.05 for all). In all groups, CA resulted in a significant reduction of AF-related hospitalization (mean rate per 1 patient-years [before and after CA]; HFpEF [1.8 versus 0.3], HFmrEF [1.1 versus 0.2], HFrEF [1.1 versus 0.2], and no HF [1 versus 0.1]; P <0.01 for each comparison) and significant improvement in quality of life as measured by both the AF symptom severity score and the AF burden score ( P <0.01 for the comparison between baseline and follow-up for each score when tested separately). CONCLUSIONS: AF recurrence rates after CA were higher in patients with HF compared with those without HF, with patients with HFpEF being at the highest risk of recurrence. Nonetheless, CA was associated with a significant reduction in AF symptoms, AF-related hospitalization, and HF symptoms in most patients irrespective of HF subtypes.
0

Abstract 4113336: Characteristics and Outcomes of Ventricular Tachycardia Ablation in Patients with the HeartMate 3 Left Ventricular Assist Devices: Results From a Large Single-Center Registry

Fawzi Zghyer et al.Nov 12, 2024
HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device (LVAD). In patients with HM3 and recurrent ventricular tachycardia (VT), data on the outcomes of catheter ablation (CA) are insufficient. We report our institutional experience with CA of VT in patients with the HM3.Consecutive patients with HM3 and recurrent drug-refractory VT undergoing CA were included. Ablation sites were identified using activation/entrainment mapping (stable VTs) and/or late/fractionated potential ablation and pace-mapping (unstable VTs). Between 2016-2023 a total of 431 patients (age 58±13, INTERMACS 3±0.98, 44% ischemic cardiomyopathy) received an HM3 LVAD at our institution. Of these, 15 (3.4%) underwent CA for recurrent VT despite therapy with 1.3±0.8 antiarrhythmic drugs a median of 700 days from the LVAD surgery (2 patients <1 month from the surgery). The LV access was transseptal in 12 (80%) cases, retrograde aortic in 2 (13%) and both in 1 (7%). A total of 23 distinct VTs were targeted. Of these, 21 (91%) were mapped with activation/entrainment mapping, always utilizing an intracardiac RV reference due to excessive surface ECG noise, and 2 (9%) were hemodynamically unstable with reduced LVAD flows and targeted with substrate-based ablation. A total of 3 (13%) VTs were targeted adjacent to the HM3 inflow cannula, and 20 (87%) from substrate remote from the HM3 cannula. At post-procedural programmed ventricular stimulation, non-inducibility of all targeted VTs was achieved in 13 (87%) patients, 1 patient had residual inducible clinical VT, and in 1 patient no post-procedural programmed stimulation was performed. Periprocedural complications occurred in 1 (7%) case (small pericardial effusion not requiring intervention). At 12 months follow-up following the index procedure, no death occurred and one patient received heart transplantation. Of the remaining 14 patients, 6 (42%) remained free from VT (2 with VT ablation <1 month post-LVAD and 12 with VT ablation >=1 month post-LVAD). In this large single-center HM3 registry, a minority of patients underwent CA for recurrent drug-refractory VT (3.4% over a 7-year period). CA of VT in HM3 recipients is feasible and appears safe also when performed soon after LVAD surgery. Myocardial scar from the underlying cardiomyopathic process rather than the apical cannula is the dominant substrate responsible for VT in these patients.
0

Abstract 4140687: Characterization of the Near-Field Bipolar Voltage Substrate Using a Novel Automated Peak Frequency Algorithm in Patients Undergoing Catheter Ablation of Postinfarction Ventricular Tachycardia

Manojna Nimmagadda et al.Nov 12, 2024
Background: Ventricular tachycardia (VT) substrate characterization in patients with ischemic cardiomyopathy (ICM) utilizing conventional peak-to-peak bipolar voltage mapping is limited by preferential automatic annotation of large amplitude far-field electrograms (EGMs). Objective: To investigate the role of a novel peak frequency (PF) software that prioritizes annotation of the near-field high-frequency component of bipolar EGMs as compared to standard bipolar voltage mapping (Std-Bip) for postinfarction substrate characterization. Methods: We studied 23 patients (age 67.2±9.4 years, 95.7% male, LVEF 37.4±14.6%) undergoing catheter ablation of postinfarction VT (34.8% anterior infarction, 73.9% inferior infarction). High-density endocardial substrate maps were created in sinus rhythm (43.5%) or right ventricular pacing (56.5%) using a 16-electrode mapping catheter (HD grid, Abbott, IL). The peak-to-peak bipolar voltage of collected EGMs was analyzed in Std-Bip configuration and after applying the PF software. Results: A total of 105,815 Std-Bip and PF EGMs were analyzed. Overall, 30.6% Std-Bip EGMs had a voltage 0.5-1.5 mV and 39% a voltage <0.5 mV. After applying the PF software, 26.3% PF EGMs had a voltage 0.5-1.5 mV and 48.4% a voltage <0.5 mV (p<0.01 for comparison, Figure ). The PF software reclassified an average of 8.9% (range 3.1% to 21.9%) Std-Bip EGMs to a voltage <0.5 mV and an average 3.5% (range -7.9% to 13.5%) Std-Bip EGMs to a voltage 0.5-1.5 mV. This resulted in an average increase in LV surface area subtending low voltage (<1.5 mV) EGMs of 3.9±0.03%. Conclusions: Postinfarction substrate mapping with a PF annotation algorithm significantly improves identification of low voltage bipolar EGMs compared to Std-Bip mapping.