LN
Lorenzo Natale
Author with expertise in Biomechanics of Bipedal Locomotion in Robots and Animals
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
10
(60% Open Access)
Cited by:
2,206
h-index:
41
/
i10-index:
127
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

WALK‐MAN: A High‐Performance Humanoid Platform for Realistic Environments

Nikos Tsagarakis et al.Jun 28, 2017
In this work, we present WALK‐MAN, a humanoid platform that has been developed to operate in realistic unstructured environment, and demonstrate new skills including powerful manipulation, robust balanced locomotion, high‐strength capabilities, and physical sturdiness. To enable these capabilities, WALK‐MAN design and actuation are based on the most recent advancements of series elastic actuator drives with unique performance features that differentiate the robot from previous state‐of‐the‐art compliant actuated robots. Physical interaction performance is benefited by both active and passive adaptation, thanks to WALK‐MAN actuation that combines customized high‐performance modules with tuned torque/velocity curves and transmission elasticity for high‐speed adaptation response and motion reactions to disturbances. WALK‐MAN design also includes innovative design optimization features that consider the selection of kinematic structure and the placement of the actuators with the body structure to maximize the robot performance. Physical robustness is ensured with the integration of elastic transmission, proprioceptive sensing, and control. The WALK‐MAN hardware was designed and built in 11 months, and the prototype of the robot was ready four months before DARPA Robotics Challenge (DRC) Finals. The motion generation of WALK‐MAN is based on the unified motion‐generation framework of whole‐body locomotion and manipulation (termed loco‐manipulation). WALK‐MAN is able to execute simple loco‐manipulation behaviors synthesized by combining different primitives defining the behavior of the center of gravity, the motion of the hands, legs, and head, the body attitude and posture, and the constrained body parts such as joint limits and contacts. The motion‐generation framework including the specific motion modules and software architecture is discussed in detail. A rich perception system allows the robot to perceive and generate 3D representations of the environment as well as detect contacts and sense physical interaction force and moments. The operator station that pilots use to control the robot provides a rich pilot interface with different control modes and a number of teleoperated or semiautonomous command features. The capability of the robot and the performance of the individual motion control and perception modules were validated during the DRC in which the robot was able to demonstrate exceptional physical resilience and execute some of the tasks during the competition.
0

A Flexible and Robust Large Scale Capacitive Tactile System for Robots

Perla Maiolino et al.Apr 15, 2013
Capacitive technology allows building sensors that are small, compact and have high sensitivity. For this reason it has been widely adopted in robotics. In a previous work we presented a compliant skin system based on capacitive technology consisting of triangular modules interconnected to form a system of sensors that can be deployed on non-flat surfaces. This solution has been successfully adopted to cover various humanoid robots. The main limitation of this and all the approaches based on capacitive technology is that they require to embed a deformable dielectric layer (usually made using an elastomer) covered by a conductive layer. This complicates the production process considerably, introduces hysteresis and limits the durability of the sensors due to ageing and mechanical stress. In this paper we describe a novel solution in which the dielectric is made using a thin layer of 3D fabric which is glued to conductive and protective layers using techniques adopted in the clothing industry. As such, the sensor is easier to produce and has better mechanical properties. Furthermore, the sensor proposed in this paper embeds transducers for thermal compensation of the pressure measurements. We report experimental analysis that demonstrates that the sensor has good properties in terms of sensitivity and resolution. Remarkably we show that the sensor has very low hysteresis and effectively allows compensating drifts due to temperature variations.
0

Socially Assistive Robot to Administer and Assess the Timed Up and Go Test: A Feasibility Study

Carmela Calabrese et al.Jan 9, 2025
Abstract In standard clinical protocols, the result of neuromotor rehabilitation programs is evaluated through validated clinical scales and tests able to measure the motor performance of the patients and monitor their improvements over time. The Timed Up and Go (TUG) test is one of the most common assessments used to evaluate patients’ dynamic balance, as well as their mobility. However, in its traditional version, the TUG test does not provide quantitative information on gait performances—only subjectively observed by the clinician—and does not measure the timing of the different phases involved in its execution. The availability of additional quantitative information would indeed be useful for the clinicians to formulate a more accurate assessment of patient performance and define a personalized treatment plan. In this sense, the use of Socially Assistive Robots (SARs) could help improving the assessment of patient performance, relieving at the same time the physiotherapists from time consuming tasks. The goal of this feasibility study is twofold: (1) to assess the quality of the TUG functionality implemented on the robot from a technical standpoint and (2) to evaluate the perception of the “R1-TUG” solution from its potential end-users point of view, in terms of usability and acceptability. A set of tests involving a sample of healthy volunteers revealed that the adoption of a SAR as an assessment tool, could improve the ability of the physiotherapist to objectively assess the subject’s movement performance while ensuring an adequate level of usability and acceptability from the participants. This work represents a promising result for the future use of the robotic solutions within a rehabilitation context.