BS
Bruna Sasso
Author with expertise in Optimization of Perioperative Fluid Therapy
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
6
(50% Open Access)
Cited by:
1
h-index:
31
/
i10-index:
63
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Monocyte distribution width (MDW) kinetic for monitoring sepsis in intensive care unit

Luisa Agnello et al.Apr 22, 2024
Abstract Objectives Monocyte distribution width (MDW) is a measure of monocyte anisocytosis. In this study, we assessed the role of MDW, in comparison to C-reactive protein (CRP), procalcitonin (PCT), and lactate, as a screening and prognostic biomarker of sepsis in intensive care unit (ICU) by longitudinally measuring it in the first 5 days of hospital stay. Methods We considered all consecutive patients admitted to the ICU. At admission, patients were classified as septic or not according to Sepsis-3 criteria. MDW, CRP, PCT, and lactate were measured daily in the first 5 days of hospitalization. ICU mortality was also recorded. Results We included 193 patients, 62 with sepsis and 131 without sepsis (controls). 58% and 26 % of the patients, with and without sepsis respectively, died during ICU stay. MDW showed the highest accuracy for sepsis detection, superior to CRP, PCT, and lactate (AUC of 0.840, 0.755, 0.708, 0.622, respectively). At admission, no biomarker predicts ICU mortality in patients with sepsis. The kinetic of all biomarkers during the first 5 days of hospitalization was associated with ICU mortality. Noteworthy, above all, the kinetic of MDW showed the best accuracy. Specifically, an increase or decrease in MDW from day 1–4 and 5 was significantly associated with mortality or survival, respectively. Conclusions MDW is a reliable diagnostic and prognostic sepsis biomarker, better than traditional biomarkers.
0
Citation1
0
Save
0

Evaluation of core Biomarkers of Alzheimer’s disease in saliva and plasma measured by chemiluminescent enzyme immunoassays on a fully automated platform

Luisa Agnello et al.Apr 19, 2024
Abstract Background. Cerebrospinal fluid (CSF) core biomarkers of Alzheimer’s disease (AD), including amyloid peptide beta-42 (Aβ42), Aβ42/40 ratio, and phosphorylated tau (pTau), are precious tools for diagnosing AD. However, their use in clinical practice is limited due to the invasiveness of CSF collection. Thus, there is intensive research to find alternative, noninvasive, and widely accessible biological matrices to measure AD core biomarkers. In this study, we measured AD core biomarkers in saliva and plasma by a fully automated platform. Methods. We enrolled all consecutive patients with cognitive decline. For each patient, we measured Aβ42, Aβ40, and pTau levels in CSF, saliva, and plasma by Lumipulse G1200 (Fujirebio). Results. We included forty-two patients, of whom 27 had AD. Levels of all biomarkers significantly differed in the three biofluids, with saliva having the lowest and CSF the highest levels of Aβ42, Aβ40, and pTau. A positive correlation of pTau and Aβ42/40 ratio levels in CSF and plasma was detected, while no correlation between any biomarker in CSF and saliva was found. Conclusions. Our findings suggest that plasma but not saliva could represent a surrogate biofluid for measuring core AD biomarkers. Specifically, plasma Aβ42/40 ratio and pTau could serve as surrogates of the corresponding CSF biomarkers.
0

Evaluation of core Biomarkers of Alzheimer’s disease in saliva and plasma measured by chemiluminescent enzyme immunoassays on a fully automated platform

Luisa Agnello et al.Jul 12, 2024
Abstract Cerebrospinal fluid (CSF) core biomarkers of Alzheimer’s disease (AD), including amyloid peptide beta-42 (Aβ42), Aβ42/40 ratio, and phosphorylated tau (pTau), are precious tools for supporting AD diagnosis. However, their use in clinical practice is limited due to the invasiveness of CSF collection. Thus, there is intensive research to find alternative, noninvasive, and widely accessible biological matrices to measure AD core biomarkers. In this study, we measured AD core biomarkers in saliva and plasma by a fully automated platform. We enrolled all consecutive patients with cognitive decline. For each patient, we measured Aβ42, Aβ40, and pTau levels in CSF, saliva, and plasma by Lumipulse G1200 (Fujirebio). We included forty-two patients, of whom 27 had AD. Levels of all biomarkers significantly differed in the three biofluids, with saliva having the lowest and CSF the highest levels of Aβ42, Aβ40, and pTau. A positive correlation of pTau, Aβ42/40 ratio, and pTau/Aβ42 ratio levels in CSF and plasma was detected, while no correlation between any biomarker in CSF and saliva was found. Our findings suggest that plasma but not saliva could represent a surrogate biofluid for measuring core AD biomarkers. Specifically, plasma Aβ42/40 ratio, pTau/Aβ42 ratio, and pTau could serve as surrogates of the corresponding CSF biomarkers.