JM
Junpeng Ma
Author with expertise in Modular Multilevel Converters in HVDC Systems
Achievements
This user has not unlocked any achievements yet.
Key Stats
Upvotes received:
0
Publications:
9
(11% Open Access)
Cited by:
1
h-index:
19
/
i10-index:
35
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Capacitor Voltage Balancing Method for the Hybrid Multilevel Converter Considering Grid Voltage Sags

Rui Zhang et al.May 29, 2024
Compared to the traditional modular multilevel converter (MMC) and alternative arm converter (AAC), the hybrid multilevel converter (HMC) exhibits superiority in terms of cost and volume.In the HMC, the pulse width of the direction switch (DS) is conventionally utilized to maintain capacitor voltage balancing (CVB).However, this method has certain limitations, including a restricted range of modulation indices and the inability to support pure reactive power operation.To address these drawbacks, a new CVB method based on the phase angle of the DS is proposed in this paper.Compared to the traditional method, the proposed method enables the HMC to achieve a full range of modulation index and four-quadrant operation.Additionally, it demonstrates improved performance in terms of SM capacitance and capacitor voltage ripple, especially under severe grid voltage sags and low power factors.A comparative analysis is conducted between two CVB methods, focusing on the SM number, switch number, and SM capacitance.Furthermore, a unified control strategy considering asymmetrical and symmetrical grid voltage sags is proposed for these two CVB methods.Finally, the effectiveness and superiority of the proposed CVB methods are verified by simulation and experimental testing.
0

A Thyristor-Based Solid-State DC Circuit Breaker with A Three-Winding Coupled Inductor

Shunliang Wang et al.Jan 1, 2025
Thyristor-based solid-state circuit breakers (TCBs) have become a popular protection solution for DC microgrids, due to their low construction cost, high efficiency, and fast response time. Despite numerous TCBs being proposed, the majority of them still suffer from low controllability, low current interrupting reliability, slow fault isolation, poor reclosing protection, and high conduction loss. Inspired by these issues, a novel TCB with a three-winding coupled inductor is proposed in this paper. First, it could interrupt both operating and fault currents actively and reliably with its bidirectional symmetric construction, ensuring high controllability and reliability. Second, during the current interrupting process, the arrester immediately works after the proposed TCB acts, which makes the fault currents at both source and load sides drop, thus effectively suppressing the fault currents. Third, the capacitor and thyristors in the triggering circuits can automatically restore to their initial states after interrupting the current, thus ensuring a reclosing protection function with no extra operation sequences. Fourth, since the conducting branch only contains one set of parallel thyristors and an inductor coil, the conduction loss of the proposed TCB is low, thus ensuring effectiveness. The working principles, design guidelines, and experimental results are presented. The advantages of the proposed TCB are further demonstrated through comparison with some existing schemes.