LS
Luiz Silva
Author with expertise in Management of Cardiac Arrest and Resuscitation
Achievements
This user has not unlocked any achievements yet.
Key Stats
Upvotes received:
0
Publications:
4
(25% Open Access)
Cited by:
0
h-index:
15
/
i10-index:
18
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
1

A Template for Translational Bioinformatics: Facilitating Multimodal Data Analyses in Preclinical Models of Neurological Injury

Hunter Gaudio et al.Jul 19, 2023
Abstract Background Pediatric neurological injury and disease is a critical public health issue due to increasing rates of survival from primary injuries (e.g., cardiac arrest, traumatic brain injury) and a lack of monitoring technologies and therapeutics for the treatment of secondary neurological injury. Translational, preclinical research facilitates the development of solutions to address this growing issue but is hindered by a lack of available data frameworks and standards for the management, processing, and analysis of multimodal data sets. Methods Here, we present a generalizable data framework that was implemented for large animal research at the Children’s Hospital of Philadelphia to address this technological gap. The presented framework culminates in an interactive dashboard for exploratory analysis and filtered data set download. Results Compared with existing clinical and preclinical data management solutions, the presented framework accommodates heterogeneous data types (single measure, repeated measures, time series, and imaging), integrates data sets across various experimental models, and facilitates dynamic visualization of integrated data sets. We present a use case of this framework for predictive model development for intra-arrest prediction of cardiopulmonary resuscitation outcome. Conclusions The described preclinical data framework may serve as a template to aid in data management efforts in other translational research labs that generate heterogeneous data sets and require a dynamic platform that can easily evolve alongside their research.
0

Amplitude spectrum area is dependent on the electrocardiogram magnitude: evaluation of different normalization approaches

Luiz Silva et al.Nov 13, 2024
Abstract Objective: Amplitude Spectrum Area (AMSA) of the electrocardiogram (ECG) waveform during ventricular fibrillation (VF) has shown promise as a predictor of defibrillation success during cardiopulmonary resuscitation (CPR). However, AMSA relies on the magnitude of the ECG waveform, raising concerns about reproducibility across different settings that may introduce magnitude bias. This study aimed to evaluate different AMSA normalization approaches and their impact on removing bias while preserving predictive value. Approach: ECG were recorded in 118 piglets (1-2 months old) during a model of asphyxia-associated VF cardiac arrest and CPR. An initial subset (91/118) was recorded using one device (Device 1), and the remaining piglets were recorded in the second device (Device 2). Raw AMSA and three ECG magnitude metrics were estimated to assess magnitude-related bias between devices. Five AMSA normalization approaches were assessed for their ability to remove detected bias and to classify defibrillation success. Main results: Device 2 showed significantly lower ECG magnitude and raw AMSA compared to Device 1. CPR-based AMSA normalization approaches mitigated device-associated bias. Raw AMSA normalized by the average AMSA in the 1st minute of CPR (AMSA1m-cpr) exhibited the best sensitivity and specificity for classification of successful and unsuccessful defibrillation. While the optimal AMSA1m-cpr thresholds for balanced sensitivity and specificity were consistent across both devices, the optimal raw AMSA thresholds varied between the two devices. The area under the receiver operating characteristic curve for AMSA1m-cpr did not significantly differ from raw AMSA for both devices (Device 1: 0.74 vs. 0.88, P=0.14; Device 2: 0.56 vs. 0.59, P=0.81). Significance: Unlike raw AMSA, AMSA1m-cpr demonstrated consistent results across different devices while maintaining predictive value for defibrillation success. This consistency has important implications for the widespread use of AMSA and the development of future guidelines on optimal AMSA thresholds for successful defibrillation.&#xD;