XS
Xiaoyan Sun
Author with expertise in Fiber Optic Sensor Technology
Achievements
This user has not unlocked any achievements yet.
Key Stats
Upvotes received:
0
Publications:
6
(17% Open Access)
Cited by:
1
h-index:
22
/
i10-index:
53
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Bronchoscopic holmium laser ablation continuous cryoablation for the treatment of airway stenosis caused by tissue hyperplasia after tracheal intubation: clinical case observation

Qingjie Yang et al.Jul 1, 2024
: This study aimed to design a standardised bronchoscopic holmium laser ablation continuous cryoablation for the treatment of airway stenosis caused by tissue hyperplasia after tracheal intubation and to retrospectively analyse its safety and feasibility. We collected the data of patients who had undergone bronchoscopic holmium laser ablation continuous cryoablation due to airway stenosis caused by tracheal mucosal tissue hyperplasia after tracheal intubation. The patients' baseline characteristics, ablation effects, surgical complications and other data were analysed. In total, 16 patients were enrolled in this study. On average, airway stenosis occurred 96.00 (interquartile range, 69.75–152.50) days after tracheal intubation and bronchoscopic holmium laser ablation continuous cryoablation took an average of 90.38 minutes (standard deviation: 16.78). After the first continuous cryoablation, 75.0% (12/16) of the patients had complete ablation of hyperplastic tissue, and 25.0% (4/16) had most of the hyperplastic tissue (>50%) removed. Altogether, 18.75% (3/16) and 6.25% (1/16) of the patients had complete ablation of hyperplastic tissue after the second and third cryoablation, respectively. Moreover, one patient (6.25%) had minimal wound bleeding postoperatively, and no other surgical complications occurred. No airway stenosis was found in all enrolled patients during follow-up 1 and 6 months after the last cryoablation. According to the above results of our small sample study indicated that bronchoscopic holmium laser ablation continuous cryoablation seems safe and effective for treating airway stenosis caused by tissue hyperplasia after tracheal intubation.
0

Electrical-feed-through elimination in micro-hemisphere resonator measurement based on mixed-frequency-excitation of different harmonic signals

Yalong Wang et al.Jun 10, 2024
To eliminate the electric feed-through introduced into the measurement of the micro-resonator by the electrical scheme, an improved mixed-frequency-excitation (MFE) method is proposed in this paper. Based on the electromechanical coupling and electric feed-through model of the micro-hemispherical resonator (MHR), the mechanism of suppressing the effect of electric feed-through on the resonant signal by the MFE method of different harmonic signals is analyzed theoretically. The MFE method can be divided into two kinds according to the frequency range. The feasibility of the method is verified by the actual measurement, and the multiplexing of the same oscillator can realize the MFE for the resonator. The measured results show that the resonant response of the micro-resonator can be measured by scanning frequency, and the signal-to-noise ratio can reach more than 10dBV. The resonant frequency of the resonator can be determined according to the position of the resonant peak. The characteristics and application range of the MFE methods of two different harmonic signals are deeply analyzed. It is revealed that the reason why the MFE in the high-frequency range causes the resonance peak deviation is due to the electrostatic negative stiffness introduced by the electric feed-through. The method and research content presented in this paper have a certain application prospect in the measurement of micro-capacitive resonators.