Healthy Research Rewards
ResearchHub is incentivizing healthy research behavior. At this time, first authors of open access papers are eligible for rewards. Visit the publications tab to view your eligible publications.
Got it
TP
Torsten Pastor
Author with expertise in Treatment and Outcomes of Hand Injuries
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
6
(50% Open Access)
Cited by:
0
h-index:
9
/
i10-index:
8
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Antegrade anterior column acetabulum fracture fixation with cannulated compression headless screws—A biomechanical study on standardized osteoporotic artificial bone

Till Berk et al.Jun 3, 2024
Purpose Due to the increase in life expectancy and high-energy traumas, anterior column acetabular fractures (ACFs) are also increasing. While open reduction and internal fixation (ORIF) is still the standard surgical procedure, minimally invasive, percutaneous fixation of osteoporotic acetabulum fractures (AF) are growing in popularity. The aim of this biomechanical study was to evaluate the biomechanical competence following antegrade fixation with a standard screw versus a cannulated compression headless screw. Methods Eight anatomical osteoporotic composite pelvises were given an anterior column fracture. Two groups of eight specimens each (n = 8) for fixation with either a 6.5 mm cannulated compression headless screw in group Anterior Acetabulum Canulated Compression Headless Screw (AACCH), or with a 6.5 mm partially threaded cannulated screw in group Anterior Acetabulum Standard Screw (AASS) where compared. Each specimen was biomechanically loaded cyclically at a rate of 2 Hz with monotonically increasing compressive load until failure. Motions were assessed by means of optical motion tracking. Results Initial construct stiffness trended higher in group AACCH at 152.4 ± 23.1 N/mm compared to group AASS at 118.5 ± 34.3 N/mm, p = 0.051. Numbers of cycles and corresponding peak load at failure, were significantly higher in group AACCH at 6734 ± 1669 cycles and 873.4 ± 166.9 N versus group AASS at 4440 ± 2063 cycles and 644.0 ± 206.3 N, p = 0.041. Failure modes were breakout of the screws around the proximal entry point. Conclusion From a biomechanical perspective, group AACCH was associated with superior biomechanical competence compared to standard partially threaded cannulated screws and could therefore be considered as valid alternative for fixation of anterior acetabulum fractures.
0
0
Save
0

45° helical plates are a valid alternative to straight plates for treatment of proximal humeral shaft fractures

Tatjana Pastor et al.Nov 25, 2024
Helical plates used for proximal humeral shaft fracture fixation avoid the radial nerve distally as compared to straight plates. To investigate in a human cadaveric model the biomechanical competence of straight lateral plates versus 45° helical plates used for fixation of proximal comminuted humeral shaft fractures, eight pairs of human cadaveric humeri were instrumented using either a long straight PHILOS plate (Group 1) or a 45° helical plate (Group 2) for treatment of an unstable proximal humeral shaft fracture. All specimens were tested under non-destructive quasi-static loading in axial compression, internal and external rotation, and bending in four directions. Subsequently, progressively increasing cyclic loading in internal rotation was applied until failure and interfragmentary movements were monitored by motion tracking. Axial displacement (mm) was 3.13 ± 0.31 in Group 1 and 2.60 ± 0.42 in Group 2, p = 0.015. Flexion/extension deformation (°) in Group 1 and Group 2 was 0.56 ± 0.42 and 0.43 ± 0.23, p = 0.551. Varus/valgus deformation (°) was 6.39 ± 0.44 in Group 1 and 5.13 ± 0.87 in Group 2, p = 0.012. Shear (mm) and torsional (°) displacement were 5.36 ± 0.76 and 17.75 ± 1.06 in Group 1, and 5.03 ± 0.46 and 16.79 ± 1.36 in Group 2, p ≥ 0.090. Cycles to catastrophic failure were 10000 ± 1401 in Group 1 and 9082 ± 1933 in Group 2, p = 0.708. From a biomechanical perspective, 45° helical plating is associated with lower axial and varus/valgus displacement under axial loading and demonstrates comparable resistance to failure versus straight plating. Therefore, 45° helical plates can be considered as a valid alternative to straight plates for treatment of proximal humeral shaft fractures.