MF
Miho Fukui
Author with expertise in Management of Valvular Heart Disease
Achievements
This user has not unlocked any achievements yet.
Key Stats
Upvotes received:
0
Publications:
10
(30% Open Access)
Cited by:
1
h-index:
21
/
i10-index:
46
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

In Vivo Computed Tomography Sizing for Redo–Transcatheter Aortic Valve Replacement in Evolut Valves: Impact on Sizing, Feasibility, and Prosthesis-Patient Mismatch

Atsushi Okada et al.Jun 27, 2024
BACKGROUND: SAPIEN3 (S3) is a ubiquitous redo–transcatheter aortic valve (TAV) replacement alternative for degenerated Evolut valves, but S3 sizing for S3-in-Evolut remains unclear. We sought to compare the impact of in vivo computed tomography (CT)-sizing on redo-TAV feasibility for S3-in-Evolut with traditional bench-sizing. METHODS: CT scans of 290 patients treated using Evolut R/PRO/PRO+ between July 2015 and December 2021 were analyzed. S3-in-Evolut was simulated using S3 outflow/neoskirt plane (NSP) at node-6, -5, and -4. CT-sizing for S3 was determined by averaging 4 areas of the Evolut stent frame at NSP level and 3 nodes below. Redo-TAV was deemed feasible if the NSP was below the coronaries, or the narrowest valve (virtual S3)-to-aorta distance was >4 mm. Risk of prosthesis-patient mismatch was estimated using predicted indexed-effective orifice area. RESULTS: Compared with bench-sizing, CT-sizing yielded smaller S3 size in 82% at node-6, 81% at node-5, and 84% at node-4. Factors associated with CT-sizing less than bench-sizing were larger index Evolut size, underexpansion of index Evolut, and shallower implant depth (all P <0.05). CT-sizing increased redo-TAV feasibility by +8% at node-6, +10% at node-5, and +4% at node-4. Redo-TAV feasibility increased with annulus size, sinotubular junction dimensions, coronary heights, index Evolut size, deeper Evolut implant depth, and lower NSP levels (all P <0.05). CT-sizing had a slightly higher estimated risk of severe prosthesis-patient mismatch (9% at node-6, 7% at node-5, and 6% at node-4), which could be mitigated by changing the NSP. CONCLUSIONS: CT-sizing for S3-in-Evolut is associated with higher feasibility of redo-TAV compared with bench-sizing, potentially reducing the risk of excessive oversizing and S3 underexpansion. Further validation using real-world clinical data is necessary.
0

Abstract 4119187: Association of CMR derived Global Longitudinal Strain with adverse Outcomes in Arrhythmogenic Cardiomyopathy.

Ali Bahbah et al.Nov 12, 2024
Background: Arrhythmogenic cardiomyopathy (ACM) is associated with high risk of ventricular arrhythmias (VA) and heart failure (HF). Different predictive models and diagnostic criteria include parameters related to myocardial structural abnormalities and right ventricular (RV) ejection fraction (EF). Nevertheless, the value of global longitudinal strain (GLS) ascertained from cardiac magnetic resonance (CMR) for risk-stratification in the context of ACM is unknown. Aim: We aim to study the association of low CMR-derived GLS with adverse outcomes in ACM patients. Methods: This was a retrospective cohort study of ACM patients seen at a single quaternary center. ACM diagnosis followed the modified 2010 ARVC modified task force criteria. Primary outcome was a composite of life-threatening VAs, heart transplant or HF hospitalization during follow up. We excluded patients who suffered events prior to diagnosis, and those with missing or inadequate CMR protocol. Imaging parameters were acquired by CMR including EF, GLS, and late gadolinium enhancement (LGE). Results: A total of 82 patients with suspected ACM were included, with a median age of 40 years, and 43 (52.4%) were females. Most common reason of initial visit was family history of genetic cardiomyopathy in 46 (56%), while 16 (20%) patients visited our clinic due to history of syncope. Out of 60 patients who had genetic testing, 21 (35%) had mutations of DSP gene. Left ventricular involvement (non-ischemic LV-LGE by CMR) was present in 42 (56.8%) out of 74 patients who had CMR with gadolinium. Median LVEF was 62% (56, 66), and RVEF of 53% (48, 59), both by CMR. Median LVGLS was -17.01% (-14.71, -18.43), while median RVGLS was -20.5% (-18.3, -24.4). A total of 15 (18%) patients suffered the composite endpoint during an average follow up period of 8 years. Patients who suffered the composite endpoint had significantly lower mean LVGLS (-15.04% vs -16.70%, p= 0.048), and lower average RVGLS (-18.45% vs -21.33%, p=0.035) compared to patients free from the adverse outcome. Meanwhile there was no significant difference in LVEF (60.13% vs 61.18%, p=0.67), nor in RVEF (49.13% vs 54.01%, p=0.065) between the two groups. Conclusion: Lower GLS was significantly associated with VAs and HF hospitalizations in our patient population. CMR derived GLS can be used as an important prognostic parameter of adverse outcomes in patients with suspected ACM. Especially in those with LV involvement and high genetic predisposition as our cohort.