JM
Jiahui Ma
Author with expertise in Wave Control in Complex Media
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
6
(50% Open Access)
Cited by:
0
h-index:
19
/
i10-index:
52
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Intraoperative hypotension is associated with decreased long-term survival in older patients after major noncardiac surgery: Secondary analysis of three randomized trials

Naping Chen et al.Jul 1, 2024
To assess the association of intraoperative hypotension with long-term survivals in older patients after major noncardiac surgery mainly for cancer. A secondary analysis of databases from three randomized trials with long-term follow-up. The underlying trials were conducted in 17 tertiary hospitals in China. Patients aged 60 to 90 years who underwent major noncardiac thoracic or abdominal surgeries (≥ 2 h) in a single center were included in this analysis. Restricted cubic spline models were employed to determine the lowest mean arterial pressure (MAP) threshold that was potentially harmful for long-term survivals. Patients were arbitrarily divided into three groups according to the cumulative duration or area under the MAP threshold. The association between intraoperative hypotension exposure and long-term survivals were analyzed with the Cox proportional hazard regression models. Our primary endpoint was overall survival. Secondary endpoints included recurrence-free and event-free survivals. A total of 2664 patients (mean age 69.0 years, 34.9% female sex, 92.5% cancer surgery) were included in the final analysis. MAP < 60 mmHg was adopted as the threshold of intraoperative hypotension. Patients were divided into three groups according to duration under MAP < 60 mmHg (<1 min, 1–10 min, and > 10 min) or area under MAP <60 mmHg (< 1 mmHg⋅min, 1–30 mmHg⋅min, and > 30 mmHg⋅min). After adjusting confounders, duration under MAP < 60 mmHg for > 10 min was associated with a shortened overall survival when compared with the < 1 min patients (adjusted hazard ratio [HR] 1.31, 95% confidence interval [CI] 1.09 to 1.57, P = 0.004); area under MAP < 60 mmHg for > 30 mmHg⋅min was associated with a shortened overall survival when compared with the < 1 mmHg⋅min patients (adjusted HR 1.40, 95% CI 1.16 to 1.68, P < 0.001). Similar associations exist between duration under MAP < 60 mmHg for > 10 min or area under MAP < 60 mmHg for > 30 mmHg⋅min and recurrence-free or event-free survivals. In older patients who underwent major noncardiac surgery mainly for cancer, intraoperative hypotension was associated with worse overall, recurrence-free, and event-free survivals.
0

A self-attention armed optronic transformer in imaging through scattering media

Zicheng Huang et al.Aug 6, 2024
Imaging through scattering media has been a pervasive issue across many fields. Recently, the optronic fully convolutional neural network (OP-FCNN), an opto-electronic deep learning (DL) method using cascaded optical convolutional layers, has shown feasibility in speckle reconstruction and significance for imaging through scattering media. However, achieving higher performance requires cascading deeper optical layers, posing challenges for compact system designs. Here, we propose the optronic Transformer (OPT), a compact opto-electronic DL structure proven effective for imaging through scattering media. The core of OPT utilizes spatial light modulators (SLMs) and optical micro-lens array shift systems to implement the attention mechanism in optics, enabling global information acquisition without cascading extensive optical layers. In contrast to the complex optronic designs of existing OP-FCNN, OPT achieves impressive imaging performance armed with the optronic Transformer with single-head attention, significantly reducing computational complexity and the scales of the optical system. Our OPT's average imaging performance on handwritten digits and letters achieves 0.80, 0.88, 0.82, and 15.29 dB for JI, PCC, SSIM, and PSNR, respectively. The proposed OPT demonstrates superiority and low complexity for imaging through scattering media, presenting a promising opto-electronic solution for designing compact and high-performance DL imaging systems.
0

Overexpression of the Vitis amurensis Ca2+‐binding protein gene VamCP1 in Arabidopsis thaliana and grapevine improves cold tolerance

Fang Ding et al.Jan 1, 2025
Abstract Calcium ions (Ca 2+ ) are important second messengers and are known to participate in cold signal transduction. In the current study, we characterized a Ca 2+ ‐binding protein gene, VamCP1 , from the extremely cold‐tolerant grape species Vitis amurensis . VamCP1 expression varied among organs but was highest in leaves following cold treatment, peaking 24 h after treatment onset. VamCP1 was found to localize to the plasma membrane and nucleus and the gene showed transcriptional autoactivation activity. Overexpression of VamCP1 in Arabidopsis thaliana and grapevine ( V. vinifera ) resulted in transgenic plants that were more tolerant to cold stress than the wild type. This correlated with reduced accumulation of reactive oxygen species (ROS), elevated activity of antioxidant enzymes and proline content, as well as lower levels of malondialdehyde and electrolyte leakage. Additionally, the expression of genes related to cold tolerance, including C‐repeat binding factors ( CBF ) and cold‐regulated ( COR ) genes, was higher in the transgenic lines. Taken together, our results indicate that overexpression of VamCP1 enhanced cold tolerance in plants by promoting the upregulation of genes related to cold tolerance and scavenging of excessive ROS. These findings provide a foundation for the molecular breeding of cold‐tolerant grapevine.
0

Real–world outcomes on myopia management efficacy of diverse segmented defocus optics (DSDO) and defocus incorporated multiple segments (DIMS) spectacle lenses in Chinese children: An initial 12–month prospective clinical study

Yuzhuo Fan et al.Jan 1, 2025
To investigate the 12-month effectiveness of Diverse Segmented Defocus Optics (DSDO) and Defocus Incorporated Multiple Segments (DIMS) spectacle lenses in a real-world clinical population in myopic and pre-myopic Chinese children. About 364 subjects prescribed DSDO or DIMS were enrolled. Axial length (AL) and cycloplegic spherical equivalent refraction (SER) changes over 12 months were measured. The subjects were further divided into age sub-group (6-9; 10-14) and SER sub-group (+0.75D≤SER<-0.50D; -0.50D≤SER<-2.00D; -2.00D≤SER<-4.00D; SER≤-4.0D). Contrast sensitivity and visual experience were also reported. The rate of myopia progression was compared with historical single-vision spectacles (SVS) lenses data to evaluate the effectiveness of the regime. 317 subjects were analyzed. At 12-month, AL changes in the DSDO and DIMS group were 0.16±0.16 mm and 0.21±0.22 mm, respectively (P = 0.0202). DSDO spectacle lenses had better control effect in +0.75D≤SER<-0.50D and SER≤-2.0D sub-groups. The proportion of participants had no greater than 0.20 mm AL elongation was 65.00% and 55.41% of in DSDO and DIMS group separately. Myopia control effect in DSDO group was 47%-69% and 33%-62% in DIMS group compared to historical SVS lenses. Both DSDO and DIMS spectacle lenses retarded AL elongation. DSDO showed more stable myopia control effect comparing to DIMS, especially in groups of SER≤-2.0D sub-groups and older patients. DSDO showed initial potential myopia prevention effect in pre-myopic children compared with historical SVS lenses data. However, the small sample and no control group in pre-myopes of this study are key limitations. Further research is needed to confirm and understand DSDO's role for pre-myopic children.