JC
Jie Cheng
Author with expertise in Particle Physics and High-Energy Collider Experiments
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
7
(86% Open Access)
Cited by:
1,047
h-index:
22
/
i10-index:
33
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

New Measurement of Antineutrino Oscillation with the Full Detector Configuration at Daya Bay

Fengpeng An et al.Sep 11, 2015
We report a new measurement of electron antineutrino disappearance using the fully constructed Daya Bay Reactor Neutrino Experiment. The final two of eight antineutrino detectors were installed in the summer of 2012. Including the 404 days of data collected from October 2012 to November 2013 resulted in a total exposure of 6.9×10^{5} GW_{th} ton days, a 3.6 times increase over our previous results. Improvements in energy calibration limited variations between detectors to 0.2%. Removal of six ^{241}Am-^{13}C radioactive calibration sources reduced the background by a factor of 2 for the detectors in the experimental hall furthest from the reactors. Direct prediction of the antineutrino signal in the far detectors based on the measurements in the near detectors explicitly minimized the dependence of the measurement on models of reactor antineutrino emission. The uncertainties in our estimates of sin^{2}2θ_{13} and |Δm_{ee}^{2}| were halved as a result of these improvements. An analysis of the relative antineutrino rates and energy spectra between detectors gave sin^{2}2θ_{13}=0.084±0.005 and |Δm_{ee}^{2}|=(2.42±0.11)×10^{-3} eV^{2} in the three-neutrino framework.
0
Citation208
0
Save
0

First measurement of the yield of He8 isotopes produced in liquid scintillator by cosmic-ray muons at Daya Bay

Fengpeng An et al.Jul 15, 2024
Daya Bay presents the first measurement of cosmogenic He8 isotope production in liquid scintillator, using an innovative method for identifying cascade decays of He8 and its child isotope, Li8. We also measure the production yield of Li9 isotopes using well-established methodology. The results, in units of 10−8μ−1g−1 cm2, are 0.307±0.042, 0.341±0.040, and 0.546±0.076 for He8, and 6.73±0.73, 6.75±0.70, and 13.74±0.82 for Li9 at average muon energies of 63.9 GeV, 64.7 GeV, and 143.0 GeV, respectively. The measured production rate of He8 isotopes is more than an order of magnitude lower than any other measurement of cosmogenic isotope production. It replaces the results of previous attempts to determine the ratio of He8 to Li9 production that yielded a wide range of limits from 0% to 30%. The results provide future liquid-scintillator-based experiments with improved ability to predict cosmogenic backgrounds.Received 8 February 2024Revised 28 March 2024Accepted 30 May 2024DOI:https://doi.org/10.1103/PhysRevD.110.L011101© 2024 American Physical SocietyPhysics Subject Headings (PhySH)Research AreasNeutrino oscillationsTechniquesNeutrino detectionParticles & FieldsNuclear Physics
0

A Study on Graph Theory Application and Efficacy of Cybersecurity Situational Awareness in Industrial IoT System

Jie Cheng et al.Jan 1, 2024
Abstract This paper proposes a network security situational awareness model based on graph theory, with the primary goal of improving industrial IoT system security. At the beginning of this paper, graph theory is explained in depth, the mutual transformation of directed and undirected graphs is proposed, the empowerment graph abstracted from practical problems is defined, matrix storage is used to realize graph storage, and an isomorphism function is proposed to realize isomorphism judgment of graphs. Based on the principles of graph theory, we develop a network security situational awareness model and suggest a network risk assessment system. This system utilizes risk indices for vulnerability, services, hosts, and networks and assesses the risk, threat, and posture of a specific asset. The efficacy of the cyber security situational awareness model is examined. The average precision rate, recall rate, and F1 value of this paper’s model reach 99.2%, 98.9%, and 97.05%, respectively. The performance of the recognition precision rate of different cyber-attack types is 1%~8% higher than that of the CN model. The leakage rate and false alarm rate of network attacks are 5.41% and 6.16%, respectively, and the overall accuracy rate reaches 95.48%. In terms of the running effect, the average absolute error and mean squared error of this paper’s model are 0.1302 and 0.2709, which are lower than other comparison models.