DF
David Foley
Author with expertise in Liver Transplantation and Graft Survival Analysis
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
10
(60% Open Access)
Cited by:
1,628
h-index:
52
/
i10-index:
147
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Efficacy and safety of left atrial appendage closure with WATCHMAN in patients with or without contraindication to oral anticoagulation: 1-Year follow-up outcome data of the EWOLUTION trial

Lucas Boersma et al.Jun 1, 2017
Left atrial appendage (LAA) occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials.EWOLUTION was designed to provide data in routine practice from a prospective multicenter registry.A total of 1025 patients scheduled for a WATCHMAN implant were prospectively and sequentially enrolled at 47 centers. Indication for LAA closure was based on European Society of Cardiology guidelines. Follow-up and transesophageal echocardiography (TEE) were performed per local practice.The baseline CHA2DS2-VASc score was 4.5 ± 1.6; the mean age was 73.4 ± 9 years; previous transient ischemic attack/ischemic stroke was present in 312 (30.5%), 155 (15.1%) had previous hemorrhagic stroke, and 320 (31.3%) had a history of major bleeding; and 750 (73%) were deemed unsuitable for oral anticoagulation therapy. WATCHMAN implant succeeded in 1005 (98.5%) of patients, without leaks >5 mm in 1002 (99.7%) with at least 1 TEE follow-up in 875 patients (87%). Antiplatelet therapy was used in 784 (83%), while vitamin K antagonists were used in only 75 (8%). At 1 year, mortality was 98 (9.8%), reflecting the advanced age and comorbidities in this population. Device thrombus was observed in 28 patients at routine TEE (3.7%) and was not correlated with the drug regimen (P = .14). Ischemic stroke rate was 1.1% (relative risk 84% vs estimated historical data); the major bleeding rate was 2.6% and was predominantly (2.3%) nonprocedure/device related.LAA closure with the WATCHMAN device has a high implant and sealing success. This method of stroke risk reduction appears to be safe and effective with an ischemic stroke rate as low as 1.1%, even though 73% of patients had a contraindication to and were not using oral anticoagulation.
0

Donation After Cardiac Death

David Foley et al.Oct 20, 2005
In Brief Objective: To determine whether the outcomes of liver transplantation (LTx) from donation after cardiac death (DCD) donors are equivalent to those from donation after brain death (DBD) donors. Summary Background Data: Because of the significant donor organ shortage, more transplant centers are using livers recovered from DCD donors. However, long-term, single-center outcomes of liver transplantation from DCD donors are limited. Methods: From January 1, 1993, to July 31, 2002, 553 liver transplants were performed from DBD donors and 36 were performed from DCD donors. Differences in event rates between the groups were compared with Kaplan-Meier estimates and the log-rank test. Differences in proportion and differences of means between the groups were compared with Fisher exact test and the Wilcoxon rank sum test, respectively. Results: Mean warm ischemic time at recovery in the DCD group was 17.8 ± 10.6 minutes. The overall rate of biliary strictures was greater in the DCD group at 1 year (33% versus 10%) and 3 years (37% versus 12%; P = 0.0001). The incidence of hepatic artery thrombosis, portal vein stenosis/thrombosis, ischemic-type biliary stricture (ITBS), and primary nonfunction were similar between groups. However, the incidence of both hepatic artery stenosis (16.6% versus 5.4%; P = 0.001) and hepatic abscess and biloma formation (16.7% versus 8.3%; P = 0.04) were greater in the DCD group. Trends toward worse patient and graft survival and increased incidence of ITBS were seen in DCD donors greater than 40 years compared with DCD donors less than 40 years. Overall patient survival at 1 year (DCD, 80%; versus DBD, 91%) and 3 years (DCD, 68%; versus DBD, 84%) was significantly less in the DCD group (P = 0.002). Similarly, graft survival at 1 year (DCD, 67%; versus DBD, 86%) and 3 years (DCD, 56%; versus DBD, 80%) were significantly less in the DCD group (P = 0.0001). Conclusions: Despite similar rates of primary nonfunction, LTx after controlled DCD resulted in worse patient and graft survival compared with LTx after DBD and increased incidence of biliary complications and hepatic artery stenosis. However, overall results of LTx after controlled DCD are encouraging; and with careful donor and recipient selection, LTx after DCD may successfully increase the donor liver pool. Many transplant centers have increased the utilization of livers recovered from donation after cardiac death (DCD) donors for transplantation. Long-term, single-center outcome data exist but are limited by low volume. This analysis compares outcomes of 36 liver transplants (LTx) after DCD to 553 LTx after donation after brain death (DBD).
0

Biliary Complications After Liver Transplantation From Donation After Cardiac Death Donors

David Foley et al.Feb 26, 2011
This study evaluates the long-term outcomes, biliary complication rates, and risk factors for biliary complications after liver transplantation from "donation after cardiac death" (DCD) donors.Recent enthusiasm toward increased use of DCD donors' livers is mitigated by high biliary complication rates. Predictive risk factors for the development of biliary complications after DCD liver transplantation remain incompletely defined.We performed a retrospective review of 1157 "donation after brain death" (DBD) and 87 DCD liver transplants performed between January 1, 1993, and December 31, 2008. Patient and graft survivals and complication rates within the first year of transplantation were compared between DBD and DCD groups. Cox proportional hazards models were used to assess the influence of potential risk factors.Patient survival was significantly lower in the DCD group compared with the DBD group at 1, 5, 10, and 15 years (DCD: 84%, 68%, 54%, and 54% vs DBD: 91%, 81%, 67%, and 58%; P < 0.01). Graft survival was also significantly lower in the DCD group compared with the DBD group at 1, 5, 10, and 15 years (DCD: 69%, 56%, 43%, 43% vs DBD: 86%, 76%, 60%, 51%; P < 0.001). Rates of overall biliary complications (OBC) (DCD: 47% vs DBD: 26%; P < 0.01) and ischemic cholangiopathy (IC) (DCD: 34% vs DBD: 1%; P < 0.01) were significantly higher in the DCD group. Donor age [hazard ratio (HR): 1.04; P < 0.01] and donor age greater than 40 years (HR: 3.13; P < 0.01) were significant risk factors for the development of OBC. Multivariate analysis revealed that cold ischemic time (CIT) greater than 8 hours (HR: 2.46; P = 0.05) and donor age greater than 40 years (HR: 2.90; P < 0.01) significantly increased the risk of IC.Long-term patient and graft survival after DCD liver transplantation remain significantly lower but acceptable when compared with DBD liver transplantations. Donor age and CIT greater than 8 hours are the strongest predictors for the development of IC. Careful selection of younger DCD donors and minimization of CIT may limit the incidence of severe biliary complications and improve the successful utilization of DCD donors' livers.
0

Evaluating Real-World Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology

Lucas Boersma et al.Apr 1, 2019
Background: Left atrial appendage occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials. Evaluating real-life clinical outcomes in atrial fibrillation patients receiving the WATCHMAN left atrial appendage closure technology was designed to collect prospective multicenter outcomes of thromboembolic events, bleeding, and mortality for patients implanted with a WATCHMAN in routine daily practice. Methods: One thousand twenty patients with a WATCHMAN implant procedure were prospectively followed in 47 centers. Left atrial appendage occlusion indication was based on the European Society of Cardiology guidelines. Follow-up and imaging were performed per local practice up to a median follow-up of 2 years. Results: Included population was old (age 73.4±8.9 years), at high risk for stroke (311 prior ischemic stroke/transient ischemic attack and 153 prior hemorrhagic stroke) and bleeding (318 prior major bleeding), with CHA 2 DS 2 -VASc score ≥5 in 49%, hypertension, abnormal renal/liver function, stroke, bleeding history or predisposition, Labile international normalized ratio, elderly, drugs/alcohol concomitantly ≥3 in 40% and oral anticoagulation contraindication in 72%. During follow-up, 161 patients (16.4%) died, 22 strokes were observed (1.3/100 patient-years, 83% reduction versus historic data), and 47 major nonprocedural bleeding events (2.7/100 patient-years, 46% reduction versus historic data). Stroke and bleeding rates were consistently lower than historic data in those with prior ischemic (−76% and −41%) or hemorrhagic (−81% and 67%) stroke and prior bleeding (−85% and −30%). Lowest bleeding rates were seen in patients with early discontinuation of dual antiplatelet therapy. Patients with early discontinuation of antithrombotic therapy showed lower bleeding rates, while they were highest for those with prior bleeding. Device thrombus was observed in 34 patients (4.1%) and was not correlated to drug regimen during follow-up ( P =0.28). Conclusions: During the complete 2-year follow-up of Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology, patients with a WATCHMAN left atrial appendage occlusion device had consistently low rates of stroke and nonprocedural bleeding, although most were contraindicated to oral anticoagulation and used only single antiplatelet therapy or nothing. Clinical Trial Registration: URL: https://clinicaltrials.gov . Unique identifier: NCT01972282.