MI
M. Iliescu
Author with expertise in Atomic Magnetometry Techniques
Achievements
Open Access Advocate
Cited Author
Key Stats
Upvotes received:
0
Publications:
4
(100% Open Access)
Cited by:
354
h-index:
32
/
i10-index:
83
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

A. Abud et al.Aug 1, 2024
Abstract Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.
0

First Stability Characterization for a CZT Detection System in an e+e− Collider Environment

L. Abbene et al.Nov 27, 2024
The SIDDHARTA-2 collaboration has developed a novel X-ray detection system based on cadmium-zinc-telluride (CZT, CdZnTe), marking the first application of this technology at the DAΦNE electron-positron collider at INFN-LNF. This work aims to demonstrate the stability of the detectors’ performance in terms of linearity and resolution over short and long periods, thereby establishing their suitability for precise spectroscopic measurements within a collider environment. A reference calibration spectrum is presented in association with findings from assessments of linearity and resolution stability. Additionally, this study introduces a validated model of the response function of the detector. The relative deviations from the nominal values for the source transitions, obtained by fitting the entire spectrum with a background function and the previously introduced response function, are reported. Finally, a comparison of the calibration performance with and without beams circulating in the collider’s rings is presented. These promising results pave the way for applying CZT detectors in kaonic atom studies and, more generally, in particle and nuclear physics spectroscopy.
0

SIDDHARTA-2 apparatus for kaonic atoms research on the DAΦNE collider

F. Sirghi et al.Nov 1, 2024
Abstract SIDDHARTA-2 is a state-of-the-art experiment designed to perform measurements of kaonic atoms, which are exotic atoms composed of a negatively charged kaon orbiting nucleus. These atoms constitute an exceptional probe for investigating the strong interaction in the non-perturbative regime involving strangeness. The experiment is installed at the DAΦNE electron-positron collider of the INFN National Laboratory of Frascati (INFN-LNF) in Italy, aiming to perform the first-ever measurement of the 2 p → 1s X-ray transitions in kaonic Deuterium, a crucial step towards determining the isospin-dependent antikaon-nucleon scattering lengths. Based on the experience gained with the previous SIDDHARTA experiment, which performed the most precise measurement of the kaonic Hydrogen 2 p → 1s X-ray transitions, the present apparatus has been upgraded with innovative X-Ray Silicon Drift Detectors (SDDs), distributed around a cryogenic gaseous target placed in a vacuum chamber at a short distance above the interaction region of the collider, two new veto systems and a charged kaon detector. The current work presents a comprehensive description of the SIDDHARTA-2 setup, including the optimization of its various components during the commissioning phase of the collider.