LC
Luís Curvo‐Semedo
Author with expertise in Radiomics in Medical Imaging Analysis
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
4
(50% Open Access)
Cited by:
724
h-index:
18
/
i10-index:
22
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Rectal Cancer: Assessment of Complete Response to Preoperative Combined Radiation Therapy with Chemotherapy—Conventional MR Volumetry versus Diffusion-weighted MR Imaging

Luís Curvo‐Semedo et al.Jun 14, 2011
To determine diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging for assessment of complete tumor response (CR) after combined radiation therapy with chemotherapy (CRT) in patients with locally advanced rectal cancer (LARC) by means of volumetric signal intensity measurements and apparent diffusion coefficient (ADC) measurements and to compare the performance of DW imaging with that of T2-weighted MR volumetry.A retrospective analysis of 50 patients with LARC, for whom clinical and imaging data were retrieved from a previous imaging study approved by the local institutional ethical committee and for which all patients provided informed consent, was conducted. Patients underwent pre- and post-CRT standard T2-weighted MR and DW MR. Two independent readers placed free-hand regions of interest (ROIs) in each tumor-containing section on both data sets to determine pre- and post-CRT tumor volumes and tumor volume reduction rates (volume). ROIs were copied to an ADC map to calculate tumor ADCs. Histopathologic findings were the standard of reference. Receiver operating characteristic (ROC) curves were generated to compare performance of T2-weighted and DW MR volumetry and ADC. The intraclass correlation coefficient (ICC) was used to evaluate interobserver variability and the correlation between T2-weighted and DW MR volumetry.Areas under the ROC curve (AUCs) for identification of a CR that was based on pre-CRT volume, post-CRT volume, and volume, respectively, were 0.57, 0.70, and 0.84 for T2-weighted MR versus 0.63, 0.93, and 0.92 for DW MR volumetry (P = .15, .02, .42). Pre- and post-CRT ADC and ADC AUCs were 0.55, 0.54, and 0.51, respectively. Interobserver agreement was excellent for all pre-CRT measurements (ICC, 0.91-0.96) versus good (ICC, 0.61-0.79) for post-CRT measurements. ICC between T2-weighted and DW MR volumetry was excellent (0.97) for pre-CRT measurements versus fair (0.25) for post-CRT measurements.Post-CRT DW MR volumetry provided high diagnostic performance in assessing CR and was significantly more accurate than T2-weighted MR volumetry. Post-CRT DW MR was equally as accurate as volume measurements of both T2-weighted and DW MR. Pre-CRT volumetry and ADC were not reliable.
0
Citation248
0
Save
0

Tumour ADC measurements in rectal cancer: effect of ROI methods on ADC values and interobserver variability

Doenja Lambregts et al.Aug 6, 2011
To assess the influence of region of interest (ROI) size and positioning on tumour ADC measurements and interobserver variability in patients with locally advanced rectal cancer (LARC).Forty-six LARC patients were retrospectively included. Patients underwent MRI including DWI (b0,500,1000) before and 6-8 weeks after chemoradiation (CRT). Two readers measured mean tumour ADCs (pre- and post-CRT) according to three ROI protocols: whole-volume, single-slice or small solid samples. The three protocols were compared for differences in ADC, SD and interobserver variability (measured as the intraclass correlation coefficient; ICC).ICC for the whole-volume ROIs was excellent (0.91) pre-CRT versus good (0.66) post-CRT. ICCs were 0.53 and 0.42 for the single-slice ROIs versus 0.60 and 0.65 for the sample ROIs. Pre-CRT ADCs for the sample ROIs were significantly lower than for the whole-volume or single-slice ROIs. Post-CRT there were no significant differences between the whole-volume ROIs and the single-slice or sample ROIs, respectively. The SDs for the whole-volume and single-slice ROIs were significantly larger than for the sample ROIs.ROI size and positioning have a considerable influence on tumour ADC values and interobserver variability. Interobserver variability is worse after CRT. ADCs obtained from the whole tumour volume provide the most reproducible results. Key Points • ROI size and positioning influence tumour ADC measurements in rectal cancer • ROI size and positioning influence interobserver variability of tumour ADC measurements • ADC measurements of the whole tumour volume provide the most reproducible results • Tumour ADC measurements are more reproducible before, rather than after, chemoradiation treatment • Variations caused by ROI size and positioning should be taken into account when using ADC as a biomarker for tumour response.
0
Citation234
0
Save
0

Recommendations for the implementation of a national lung cancer screening program in Portugal—A consensus statement

Gabriela Fernandes et al.Aug 1, 2024
Lung cancer (LC) is a leading cause of cancer-related mortality worldwide. Lung Cancer Screening (LCS) programs that use low-dose computed tomography (LDCT) have been shown to reduce LC mortality by up to 25 % and are considered cost-effective. The European Health Union has encouraged its Member States to explore the feasibility of LCS implementation in their respective countries. The task force conducted a comprehensive literature review and engaged in extensive discussions to provide recommendations. These recommendations encompass the essential components required to initiate pilot LCS programs following the guidelines established by the World Health Organization. They were tailored to align with the specific context of the Portuguese healthcare system. The document addresses critical aspects, including the eligible population, methods for issuing invitations, radiological prerequisites, procedures for reporting results, referral processes, diagnostic strategies, program implementation, and ongoing monitoring. Furthermore, the task force emphasized that pairing LCS with evidence-based smoking cessation should be the standard of care for a high-quality screening program. This document also identifies areas for further research. These recommendations aim to guarantee that the implementation of a Portuguese LCS program ensures high-quality standards, consistency, and uniformity across centres.