MR
Marion Russell
Author with expertise in Health Effects of Air Pollution
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
3
(100% Open Access)
Cited by:
1,141
h-index:
17
/
i10-index:
23
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Prevention of pre-PCR mis-priming and primer dimerization improves low-copy-number amplifications

Quin Chou et al.Jan 1, 1992
A Hot Start Polymerase Chain Reaction (PCR) entails the withholding of at least one reagent from the reaction mixture until the reaction tube temperature has reached 60-80 degrees C. Hot Start amplification with an AmpliWax vapor barrier uses a layer of solid wax to separate the retained reagent(s) and the test sample from the bulk of the reagents until the first heating step of automated thermal cycling melts the wax and convectively mixes the two aqueous layers. Wax-mediated Hot Start PCR greatly increases the specificity, yield, and precision of amplifying low copy numbers of three HIV targets. In the presence of 1 microgram of human placental DNA (1.6 x 10(5) diploid genomes) the specificity improvement entails considerable to complete reduction in the amplification of mis-primed sequences and putative primer oligomers. When mis-priming is negligible, the procedural improvement still suppresses putative primer oligomerization. Hot Start PCR with an AmpliWax vapor barrier permits routine amplification of a single target molecule with detection by ethidium stained gel electrophoresis; nonisotopically visualized probing suffices for confirmation. The improved amplification performance is evident for target copy numbers below approximately 10(3).
0
Citation751
0
Save
0

Emissions from Electronic Cigarettes: Key Parameters Affecting the Release of Harmful Chemicals

Mohamad Sleiman et al.Jul 27, 2016
Use of electronic cigarettes has grown exponentially over the past few years, raising concerns about harmful emissions. This study quantified potentially toxic compounds in the vapor and identified key parameters affecting emissions. Six principal constituents in three different refill "e-liquids" were propylene glycol (PG), glycerin, nicotine, ethanol, acetol, and propylene oxide. The latter, with mass concentrations of 0.4–0.6%, is a possible carcinogen and respiratory irritant. Aerosols generated with vaporizers contained up to 31 compounds, including nicotine, nicotyrine, formaldehyde, acetaldehyde, glycidol, acrolein, acetol, and diacetyl. Glycidol is a probable carcinogen not previously identified in the vapor, and acrolein is a powerful irritant. Emission rates ranged from tens to thousands of nanograms of toxicants per milligram of e-liquid vaporized, and they were significantly higher for a single-coil vs a double-coil vaporizer (by up to an order of magnitude for aldehydes). By increasing the voltage applied to a single-coil device from 3.3 to 4.8 V, the mass of e-liquid consumed doubled from 3.7 to 7.5 mg puff–1 and the total aldehyde emission rates tripled from 53 to 165 μg puff–1, with acrolein rates growing by a factor of 10. Aldehyde emissions increased by more than 60% after the device was reused several times, likely due to the buildup of polymerization byproducts that degraded upon heating. These findings suggest that thermal degradation byproducts are formed during vapor generation. Glycidol and acrolein were primarily produced by glycerin degradation. Acetol and 2-propen-1-ol were produced mostly from PG, while other compounds (e.g., formaldehyde) originated from both. Because emissions originate from reaction of the most common e-liquid constituents (solvents), harmful emissions are expected to be ubiquitous when e-cigarette vapor is present.
0
Citation390
0
Save