ÉL
Éric Larose
Author with expertise in Management of Valvular Heart Disease
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
11
(100% Open Access)
Cited by:
3,405
h-index:
52
/
i10-index:
137
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Predictive Factors, Management, and Clinical Outcomes of Coronary Obstruction Following Transcatheter Aortic Valve Implantation

Henrique Ribeiro et al.Aug 14, 2013
This study sought to evaluate the main baseline and procedural characteristics, management, and clinical outcomes of patients from a large cohort of patients undergoing transcatheter aortic valve implantation (TAVI) who suffered coronary obstruction (CO).Very little data exist on CO following TAVI.This multicenter registry included 44 patients who suffered symptomatic CO following TAVI of 6,688 patients (0.66%). Pre-TAVI computed tomography data was available in 28 CO patients and in a control group of 345 patients (comparisons were performed including all patients and a cohort matched 1:1 by age, sex, previous coronary artery bypass graft, transcatheter valve type, and size).Baseline and procedural variables associated with CO were older age (p < 0.001), female sex (p < 0.001), no previous coronary artery bypass graft (p = 0.043), the use of a balloon-expandable valve (p = 0.023), and previous surgical aortic bioprosthesis (p = 0.045). The left coronary artery was the most commonly involved (88.6%). The mean left coronary artery ostia height and sinus of Valsalva diameters were lower in patients with obstruction than in control subjects (10.6 ± 2.1 mm vs. 13.4 ± 2.1 mm, p < 0.001; 28.1 ± 3.8 mm vs. 31.9 ± 4.1 mm, p < 0.001). Differences between groups remained significant after the case-matched analysis (p < 0.001 for coronary height; p = 0.01 for sinus of Valsalva diameter). Most patients presented with persistent severe hypotension (68.2%) and electrocardiographic changes (56.8%). Percutaneous coronary intervention was attempted in 75% of the cases and was successful in 81.8%. Thirty-day mortality was 40.9%. After a median follow-up of 12 (2 to 18) months, the cumulative mortality rate was 45.5%, and there were no cases of stent thrombosis or reintervention.Symptomatic CO following TAVI was a rare but life-threatening complication that occurred more frequently in women, in patients receiving a balloon-expandable valve, and in those with a previous surgical bioprosthesis. Lower-lying coronary ostium and shallow sinus of Valsalva were associated anatomic factors, and despite successful treatment, acute and late mortality remained very high, highlighting the importance of anticipating and preventing the occurrence of this complication.
0

The Complex Nature of Discordant Severe Calcified Aortic Valve Disease Grading

Marie‐Annick Clavel et al.Sep 24, 2013
With concomitant Doppler echocardiography and multidetector computed tomography (MDCT) measuring aortic valve calcification (AVC) load, this study aimed at defining: 1) independent physiologic/structural determinants of aortic valve area (AVA)/mean gradient (MG) relationship; 2) AVC thresholds best associated with severe aortic stenosis (AS); and 3) whether, in AS with discordant MG, severe calcified aortic valve disease is generally detected.Aortic stenosis with discordant markers of severity, AVA in severe range but low MG, is a conundrum, unresolved by outcome studies.Patients (n = 646) with normal left ventricular ejection fraction AS underwent Doppler echocardiography and AVC measurement by MDCT. On the basis of AVA-indexed-to-body surface area (AVAi) and MG, patients were categorized as concordant severity grading (CG) with moderate AS (AVAi >0.6 cm²/m², MG <40 mm Hg), severe AS (AVAi ≤0.6 cm²/m², MG ≥ 40 mm Hg), discordant-severity-grading (DG) with low-MG (AVAi ≤0.6 cm(2)/m(2), MG <40 mm Hg), or high-MG (AVAi >0.6 cm(2)/m(2), MG ≥40 mm Hg).The MG (discordant in 29%) was strongly determined by AVA and flow but also independently and strongly influenced by AVC-load (p < 0.0001) and systemic arterial compliance (p < 0.0001). The AVC-load (median [interquartile range]) was similar within patients with DG (low-MG: 1,619 [965 to 2,528] arbitrary units [AU]; high-MG: 1,736 [1,209 to 2,894] AU; p = 0.49), higher than CG-moderate-AS (861 [427 to 1,519] AU; p < 0.0001) but lower than CG-severe-AS (2,931 [1,924 to 4,292] AU; p < 0.0001). The AVC-load thresholds separating severe/moderate AS were defined in CG-AS with normal flow (stroke-volume-index >35 ml/m(2)). The AVC-load, absolute or indexed, identified severe AS accurately (area under the curve ≥0.89, sensitivity ≥86%, specificity ≥79%) in men and women. Upon application of these criteria to DG-low MG, at least one-half of the patients were identified as severe calcified aortic valve disease, irrespective of flow.Among patients with AS, MG is often discordant from AVA and is determined by multiple factors, valvular (AVC) and non-valvular (arterial compliance) independently of flow. The AVC-load by MDCT, strongly associated with AS severity, allows diagnosis of severe calcified aortic valve disease. At least one-half of the patients with discordant low gradient present with heavy AVC-load reflective of severe calcified aortic valve disease, emphasizing the clinical yield of AVC quantification by MDCT to diagnose and manage these complex patients.
0

Impact of Aortic Valve Calcification, as Measured by MDCT, on Survival in Patients With Aortic Stenosis

Marie‐Annick Clavel et al.Sep 1, 2014
Aortic valve calcification (AVC) load measures lesion severity in aortic stenosis (AS) and is useful for diagnostic purposes. Whether AVC predicts survival after diagnosis, independent of clinical and Doppler echocardiographic AS characteristics, has not been studied. This study evaluated the impact of AVC load, absolute and relative to aortic annulus size (AVCdensity), on overall mortality in patients with AS under conservative treatment and without regard to treatment. In 3 academic centers, we enrolled 794 patients (mean age, 73 ± 12 years; 274 women) diagnosed with AS by Doppler echocardiography who underwent multidetector computed tomography (MDCT) within the same episode of care. Absolute AVC load and AVCdensity (ratio of absolute AVC to cross-sectional area of aortic annulus) were measured, and severe AVC was separately defined in men and women. During follow-up, there were 440 aortic valve implantations (AVIs) and 194 deaths (115 under medical treatment). Univariate analysis showed strong association of absolute AVC and AVCdensity with survival (both, p < 0.0001) with a spline curve analysis pattern of threshold and plateau of risk. After adjustment for age, sex, coronary artery disease, diabetes, symptoms, AS severity on hemodynamic assessment, and LV ejection fraction, severe absolute AVC (adjusted hazard ratio [HR]: 1.75; 95% confidence interval [CI]: 1.04 to 2.92; p = 0.03) or severe AVCdensity (adjusted HR: 2.44; 95% CI: 1.37 to 4.37; p = 0.002) independently predicted mortality under medical treatment, with additive model predictive value (all, p ≤ 0.04) and a net reclassification index of 12.5% (p = 0.04). Severe absolute AVC (adjusted HR: 1.71; 95% CI: 1.12 to 2.62; p = 0.01) and severe AVCdensity (adjusted HR: 2.22; 95% CI: 1.40 to 3.52; p = 0.001) also independently predicted overall mortality, even with adjustment for time-dependent AVI. This large-scale, multicenter outcomes study of quantitative Doppler echocardiographic and MDCT assessment of AS shows that measuring AVC load provides incremental prognostic value for survival beyond clinical and Doppler echocardiographic assessment. Severe AVC independently predicts excess mortality after AS diagnosis, which is greatly alleviated by AVI. Thus, measurement of AVC by MDCT should be considered for not only diagnostic but also risk-stratification purposes in patients with AS.
0

Transradial Approach for Coronary Angiography and Interventions

Olivier Bertrand et al.Oct 1, 2010
The aim of this study was to evaluate practice of transradial approach (TRA).TRA has been adopted as an alternative access site for coronary procedures.A questionnaire was distributed worldwide with Internet-based software.The survey was conducted from August 2009 to January 2010 among 1,107 interventional cardiologists in 75 countries. Although pre-TRA dual hand circulation testing is not uniform in the world, >85% in the U.S. perform Allen or oximetry testing. Right radial artery is used in almost 90%. Judkins catheters are the most popular for left coronary artery angiographies (66.5%) and right coronary artery angiographies (58.8%). For percutaneous coronary intervention (PCI), 6-F is now standard. For PCI of left coronary artery, operators use standard extra back-up guiding catheters in >65% and, for right coronary artery 70.4% use right Judkins catheters. Although heparin remains the routine antithrombotic agent in the world, bivalirudin is frequently used in the U.S. for PCI. The incidence of radial artery occlusion before hospital discharge is not assessed in >50%. Overall, approximately 50% responded that their TRA practice will increase in the future (68.4% in the U.S.).TRA is already widely used across the world. Diagnostic and guiding-catheters used for TRA remain similar to those used for traditional femoral approach, suggesting that specialized radial catheters are not frequently used. However, there is substantial variation in practice as it relates to specific aspects of TRA, suggesting that more data are needed to determine the optimal strategy to facilitate TRA and optimize radial artery patency after catheterization.
0

A Randomized Study Comparing Same-Day Home Discharge and Abciximab Bolus Only to Overnight Hospitalization and Abciximab Bolus and Infusion After Transradial Coronary Stent Implantation

Olivier Bertrand et al.Dec 5, 2006
Background— Systematic use of coronary stents and optimized platelet aggregation inhibition has greatly improved the short-term results of percutaneous coronary interventions. Transradial percutaneous coronary interventions have been associated with a low risk of bleeding complications. It is unknown whether moderate- and high-risk patients can be discharged safely the same day after uncomplicated transradial percutaneous coronary interventions. Methods and Results— We randomized 1005 patients after a bolus of abciximab and uncomplicated transradial percutaneous coronary stent implantation either to same-day home discharge and no infusion of abciximab (group 1, n=504) or to overnight hospitalization and a standard 12-hour infusion of abciximab (group 2, n=501). The primary composite end point of the study was the 30-day incidence of any of the following events: death, myocardial infarction, urgent revascularization, major bleeding, repeat hospitalization, access site complications, and severe thrombocytopenia. The noninferiority of same-day home discharge and bolus of abciximab only compared with overnight hospitalization and abciximab bolus and infusion was evaluated. Two thirds of patients presented with unstable angina and ≈20% presented with high-risk acute coronary syndrome prior to the procedure. The incidence of the primary end point was 20.4% in group 1 and 18.2% in group 2 ( P =0.017 for noninferiority) with a troponin T–based definition of myocardial infarction; the incidence of the primary end point was 11.1% in group 1 and 9.6% in group 2 ( P =0.0004 for noninferiority) with a creatinine kinase myocardial band–based definition of myocardial infarction. No death occurred. Rate of major bleeding in both groups was extremely low at 0.8% and 0.2%, respectively. From 504 patients randomized in group 1, 88% were discharged home the same day. Conclusion— Our data suggest that same-day home discharge after uncomplicated transradial coronary stenting and bolus only of abciximab is not clinically inferior, in a wide spectrum of patients, to the standard overnight hospitalization and a bolus followed by a 12-hour infusion. This novel approach offers a safe strategy for same-day home discharge after uncomplicated coronary intervention.
0

The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement

Ronald Binder et al.May 15, 2013
This study prospectively investigated the impact of integration of a multidetector computed tomography (MDCT) annular area sizing algorithm on transcatheter aortic valve replacement (TAVR) outcomes. Appreciation of the 3-dimensional, noncircular geometry of the aortic annulus is important for transcatheter heart valve (THV) sizing. Patients being evaluated for TAVR in 4 centers underwent pre-procedural MDCT. Recommendations for balloon-expandable THV size selection were based on an MDCT sizing algorithm with an optimal goal of modest annulus area oversizing (5% to 10%). Consecutive patients who underwent TAVR with the algorithm (MDCT group) were compared with consecutive patients without the algorithm (control group). The primary endpoint was the incidence of more than mild paravalvular regurgitation (PAR), and the secondary endpoint was the composite of in-hospital death, aortic annulus rupture, and severe PAR. Of 266 patients, 133 consecutive patients underwent TAVR (SAPIEN XT THV) in the MDCT group and 133 consecutive patients were in the control group. More than mild PAR was present in 5.3% (7 of 133) of the MDCT group and in 12.8% (17 of 133) in the control group (p = 0.032). The combined secondary endpoint occurred in 3.8% (5 of 133) of the MDCT group and in 11.3% (15 of 133) of the control group (p = 0.02), driven by the difference of severe PAR. The implementation of an MDCT annulus area sizing algorithm for TAVR reduces PAR. Three-dimensional aortic annular assessment and annular area sizing should be considered for TAVR.
Load More