MM
Mitsuaki Matsumura
Author with expertise in Clinical Studies on Coronary Stents and Revascularization
Achievements
Cited Author
Key Stats
Upvotes received:
0
Publications:
9
(33% Open Access)
Cited by:
1,842
h-index:
32
/
i10-index:
60
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial

Ziad Ali et al.Oct 30, 2016
Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone.In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural MACE. We tested non-inferiority of OCT guidance to IVUS guidance (with a non-inferiority margin of 1·0 mm2), superiority of OCT guidance to angiography guidance, and superiority of OCT guidance to IVUS guidance, in a hierarchical manner. This trial is registered with ClinicalTrials.gov, number NCT02471586.Between May 13, 2015, and April 5, 2016, we randomly allocated 450 patients (158 [35%] to OCT, 146 [32%] to IVUS, and 146 [32%] to angiography), with 415 final OCT acquisitions analysed for the primary endpoint (140 [34%] in the OCT group, 135 [33%] in the IVUS group, and 140 [34%] in the angiography group). The final median minimum stent area was 5·79 mm2 (IQR 4·54-7·34) with OCT guidance, 5·89 mm2 (4·67-7·80) with IVUS guidance, and 5·49 mm2 (4·39-6·59) with angiography guidance. OCT guidance was non-inferior to IVUS guidance (one-sided 97·5% lower CI -0·70 mm2; p=0·001), but not superior (p=0·42). OCT guidance was also not superior to angiography guidance (p=0·12). We noted procedural MACE in four (3%) of 158 patients in the OCT group, one (1%) of 146 in the IVUS group, and one (1%) of 146 in the angiography group (OCT vs IVUS p=0·37; OCT vs angiography p=0·37).OCT-guided PCI using a specific reference segment external elastic lamina-based stent optimisation strategy was safe and resulted in similar minimum stent area to that of IVUS-guided PCI. These data warrant a large-scale randomised trial to establish whether or not OCT guidance results in superior clinical outcomes to angiography guidance.St Jude Medical.
0
Paper
Citation531
0
Save
0

A new optical coherence tomography-based calcium scoring system to predict stent underexpansion

Akiko Fujino et al.Apr 1, 2018
This was a retrospective study to develop and validate an optical coherence tomography (OCT)-based calcium scoring system to predict stent underexpansion.A calcium score was developed using 128 patients with pre- and post-stent OCT (test cohort) and then validated in an external cohort of 133 patients. In the test cohort, a multivariable model showed that the independent predictors of stent expansion were maximum calcium angle per 180° (regression coefficient: -7.43; p<0.01), maximum calcium thickness per 0.5 mm (-3.40; p=0.02), and calcium length per 5 mm (-2.32; p=0.01). A calcium score was then defined as 2 points for maximum angle >180°, 1 point for maximum thickness >0.5 mm, and 1 point for length >5 mm. In the validation cohort, the lesions with calcium score of 0 to 3 had excellent stent expansion, whereas the lesions with a score of 4 had poor stent expansion (96% versus 78%, p<0.01). On multivariate analysis the calcium score was an independent predictor of stent underexpansion.An OCT-based calcium scoring system can help to identify lesions that would benefit from plaque modification prior to stent implantation. Lesions with calcium deposit with maximum angle >180°, maximum thickness >0.5 mm, and length >5 mm may be at risk of stent underexpansion.
0

Safety and Effectiveness of Coronary Intravascular Lithotripsy for Treatment of Severely Calcified Coronary Stenoses

Ziad Ali et al.Sep 25, 2019
The feasibility of intravascular lithotripsy (IVL) for modification of severe coronary artery calcification (CAC) was demonstrated in the Disrupt CAD I study (Disrupt Coronary Artery Disease). We next sought to confirm the safety and effectiveness of IVL for these lesions.The Disrupt CAD II study was a prospective multicenter, single-arm post-approval study conducted at 15 hospitals in 9 countries. Patients with severe CAC with a clinical indication for revascularization underwent vessel preparation for stent implantation with IVL. The primary end point was in-hospital major adverse cardiac events (cardiac death, myocardial infarction, or target vessel revascularization). An optical coherence tomography substudy was performed to evaluate the mechanism of action of IVL, quantifying CAC characteristics and calcium plaque fracture. Independent core laboratories adjudicated angiography and optical coherence tomography, and an independent clinical events committee adjudicated major adverse cardiac events.Between May 2018 and March 2019, 120 patients were enrolled. Severe CAC was present in 94.2% of lesions. Successful delivery and use of the IVL catheter was achieved in all patients. The post-IVL angiographic acute luminal gain was 0.83±0.47 mm, and residual stenosis was 32.7±10.4%, which further decreased to 7.8±7.1% after drug-eluting stent implantation. The primary end point occurred in 5.8% of patients, consisting of 7 non-Q-wave myocardial infarctions. There was no procedural abrupt closure, slow or no reflow, or perforations. In 47 patients with post-percutaneous coronary intervention optical coherence tomography, calcium fracture was identified in 78.7% of lesions with 3.4±2.6 fractures per lesion, measuring 5.5±5.0 mm in length.In patients with severe CAC who require coronary revascularization, IVL was safely performed with high procedural success and minimal complications and resulted in substantial calcific plaque fracture in most lesions.URL: https://www.clinicaltrials.gov. Unique identifier: NCT03328949.
0

Impact of Lipidic Plaque on In-Stent and Stent Edge–Related Events After PCI in Myocardial Infarction: A PROSPECT II Substudy

Lars Kjøller‐Hansen et al.Sep 25, 2024
BACKGROUND: Lipid content in untreated nonobstructive coronary artery lesions is associated with adverse clinical outcomes, and residual in-stent or stent edge lipid may worsen outcomes after percutaneous coronary intervention (PCI). METHODS: Near-infrared spectroscopy-intravascular ultrasound was performed before and after PCI in patients with myocardial infarction. We evaluated the impact of lipid assessed by near-infrared spectroscopy (maximal lipid core burden index over 4 mm [maxLCBI 4mm ]) along with intravascular ultrasound information including residual plaque burden on in-stent or edge-related major adverse cardiac events (MACE) in de novo PCI-treated culprit coronary artery lesions. The primary end point was culprit lesion-related MACE (CL-MACE), defined as cardiac death, myocardial infarction, or unstable or progressive angina either requiring revascularization or with rapid lesion progression and classified as in-stent or stent edge–related. RESULTS: During a median follow-up of 3.8 years, 25 CL-MACE (11 stent edge–related, 13 in-stent, and 1 in-lesion without a stent) occurred in 1041 PCI-treated lesions in 768 patients. Pre-PCI or post-PCI measures of lipid content were not related to in-stent CL-MACE. However, stent edge–related CL-MACE was increased if both the post-PCI stent edge maxLCBI 4mm was greater than the upper quartile (108.7) and the stent edge plaque burden was >50% (adjusted odds ratio, 4.11 [95% CI, 1.12–15.2]; P =0.03). CONCLUSIONS: In PROSPECT II (Providing Regional Observations to Study Predictors of Events in the Coronary Tree), CL stent implantation leaving behind greater stent edge–related lipid and uncovered plaque burden was associated with an increased risk of stent edge–related CL-MACE during follow-up. In contrast, CL lipid content was not related to in-stent CL-MACE. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02171065.