MQ
Mary Quintayo
Author with expertise in Positron Emission Tomography Imaging in Oncology
Achievements
This user has not unlocked any achievements yet.
Key Stats
Upvotes received:
0
Publications:
2
(0% Open Access)
Cited by:
0
h-index:
6
/
i10-index:
4
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Adjunctive statistical standardization of quantitated adjuvant ER and PgR in CCTG MA.27.

Judy‐Anne Chapman et al.May 29, 2024
567 Background: We proposed adjunctive statistical standardization of quantitated ER and PgR to improve inter-laboratory comparability of biomarker results and therapeutic management of breast cancer. Methods: We utilized CCTG MA.27 (NCT00066573), an adjuvant phase III trial of exemestane versus anastrozole in postmenopausal women with ER+ and/or PgR+ tumours. IHC ER and PgR HSCORE and % positivity (%+) were centrally assessed by machine image quantitation, and each statistically standardized to mean of 0, standard deviation of 1 following Box-Cox variance stabilization transformations of square for ER; for PgR, 1.) natural logarithm (0.1 added to 0 HSCOREs and 0 %+), 2.) square root. The primary endpoint was STEEP distant disease-free survival (DDFS) at the longest trial follow-up of median 4.1 years; a secondary endpoint was event-free survival (EFS). Survival was described with Kaplan-Meier plots and tested with the univariate Wilcoxon (Peto-Prentice) test statistic. We examined cut-points at standard deviations about mean of 0 (<-1; (-1,0]; (0,1]; >1) and explored single cut-points. Cox multivariate regressions were adjusted for age, T and N stage, grade, lymphovascular invasion, treatment, and baseline patient demographics; 2-sided Wald tests had nominal significance if p<0.05. Results: Of the 7576 women accrued, 3048 women had machine-quantitated image analysis results: 2900 (95%) for ER; 2726 (89%) for PgR. Statistically standardized HSCORE and %+ units differentiated both univariate DDFS and EFS; DDFS was significantly different by ER levels (p<0.001) and PgR levels (p<0.001). In multivariable assessments, ER HSCORE and %+ were not significantly associated (p=0.52-0.88) with the DDFS primary endpoint in models with PgR, while higher PgR HSCORE and %+ had significantly better DDFS (p=.001, in all instances) in models with ER. Conclusions: DDFS was superior for patients with higher ER and PgR standardized units compared with those with HSCOREs and %+ <-1. The adjunctive statistical standardization of ER and PgR performed here is similar to that mandated for clinical practice by the World Health Organization for BMD. [Table: see text]
0

Adjunctive Statistical Standardization of Adjuvant Estrogen Receptor and Progesterone Receptor in Canadian Cancer Trials Group MA.27 Postmenopausal Breast Cancer Trial of Exemestane Versus Anastrozole

Judith‐Anne Chapman et al.Jun 2, 2024
PURPOSE ASCO/College of American Pathologists guidelines recommend reporting estrogen receptor (ER) and progesterone receptor (PgR) as positive with (1%-100%) staining. Statistically standardized quantitated positivity could indicate differential associations of positivity with breast cancer outcomes. METHODS MA.27 (ClinicalTrials.gov identifier: NCT00066573 ) was a phase III adjuvant trial of exemestane versus anastrozole in postmenopausal women with early-stage breast cancer. Immunochemistry ER and PgR HSCORE and % positivity (%+) were centrally assessed by machine image quantitation and statistically standardized to mean 0 and standard deviation (SD) 1 after Box-Cox variance stabilization transformations of square for ER; for PgR, (1) natural logarithm (0.1 added to 0 HSCOREs and 0%+) and (2) square root. Our primary end point was MA.27 distant disease-free survival (DDFS) at a median 4.1-year follow-up, and secondary end point was event-free survival (EFS). Univariate survival with cut points at SDs about a mean of 0 (≤–1; (–1, 0]; (0, 1]; >1) was described with Kaplan-Meier plots and examined with Wilcoxon (Peto-Prentice) test statistic. Adjusted Cox multivariable regressions had two-sided Wald tests and nominal significance P < .05. RESULTS Of 7,576 women accrued, 3,048 women's tumors had machine-quantitated image analysis results: 2,900 (95%) for ER, 2,726 (89%) for PgR, and 2,582 (85% of 3,048) with both ER and PgR. Higher statistically standardized ER and PgR HSCORE and %+ were associated with better univariate DDFS and EFS ( P < .001). In multivariable assessments, ER HSCORE and %+ were not significantly associated ( P = .52-.88) with DDFS in models with PgR, whereas higher PgR HSCORE and %+ were significantly associated with better DDFS ( P = .001) in models with ER. CONCLUSION Adjunctive statistical standardization differentiated quantitated levels of ER and PgR. Patients with higher ER- and PgR-standardized units had superior DDFS compared with those with HSCOREs and %+ ≤–1.