CR
Coleen Roehl
Author with expertise in Global Methane Emissions and Impacts
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
9
(100% Open Access)
Cited by:
2,808
h-index:
45
/
i10-index:
90
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

A method for evaluating bias in global measurements of CO&lt;sub&gt;2&lt;/sub&gt; total columns from space

Debra Wunch et al.Dec 9, 2011
Abstract. We describe a method of evaluating systematic errors in measurements of total column dry-air mole fractions of CO2 (XCO2) from space, and we illustrate the method by applying it to the v2.8 Atmospheric CO2 Observations from Space retrievals of the Greenhouse Gases Observing Satellite (ACOS-GOSAT) measurements over land. The approach exploits the lack of large gradients in XCO2 south of 25° S to identify large-scale offsets and other biases in the ACOS-GOSAT data with several retrieval parameters and errors in instrument calibration. We demonstrate the effectiveness of the method by comparing the ACOS-GOSAT data in the Northern Hemisphere with ground truth provided by the Total Carbon Column Observing Network (TCCON). We use the observed correlation between free-tropospheric potential temperature and XCO2 in the Northern Hemisphere to define a dynamically informed coincidence criterion between the ground-based TCCON measurements and the ACOS-GOSAT measurements. We illustrate that this approach provides larger sample sizes, hence giving a more robust comparison than one that simply uses time, latitude and longitude criteria. Our results show that the agreement with the TCCON data improves after accounting for the systematic errors, but that extrapolation to conditions found outside the region south of 25° S may be problematic (e.g., high airmasses, large surface pressure biases, M-gain, measurements made over ocean). A preliminary evaluation of the improved v2.9 ACOS-GOSAT data is also discussed.
0
Paper
Citation326
0
Save
0

Improved retrievals of carbon dioxide from Orbiting Carbon Observatory-2 with the version 8 ACOS algorithm

C. O’Dell et al.Dec 11, 2018
Abstract. Since September 2014, NASA's Orbiting Carbon Observatory-2 (OCO-2) satellite has been taking measurements of reflected solar spectra and using them to infer atmospheric carbon dioxide levels. This work provides details of the OCO-2 retrieval algorithm, versions 7 and 8, used to derive the column-averaged dry air mole fraction of atmospheric CO2 (XCO2) for the roughly 100 000 cloud-free measurements recorded by OCO-2 each day. The algorithm is based on the Atmospheric Carbon Observations from Space (ACOS) algorithm which has been applied to observations from the Greenhouse Gases Observing SATellite (GOSAT) since 2009, with modifications necessary for OCO-2. Because high accuracy, better than 0.25 %, is required in order to accurately infer carbon sources and sinks from XCO2, significant errors and regional-scale biases in the measurements must be minimized. We discuss efforts to filter out poor-quality measurements, and correct the remaining good-quality measurements to minimize regional-scale biases. Updates to the radiance calibration and retrieval forward model in version 8 have improved many aspects of the retrieved data products. The version 8 data appear to have reduced regional-scale biases overall, and demonstrate a clear improvement over the version 7 data. In particular, error variance with respect to TCCON was reduced by 20 % over land and 40 % over ocean between versions 7 and 8, and nadir and glint observations over land are now more consistent. While this paper documents the significant improvements in the ACOS algorithm, it will continue to evolve and improve as the CO2 data record continues to expand.
0
Paper
Citation322
0
Save
0

The Orbiting Carbon Observatory-2: first 18 months of science data products

A. Eldering et al.Feb 15, 2017
Abstract. The Orbiting Carbon Observatory-2 (OCO-2) is the first National Aeronautics and Space Administration (NASA) satellite designed to measure atmospheric carbon dioxide (CO2) with the accuracy, resolution, and coverage needed to quantify CO2 fluxes (sources and sinks) on regional scales. OCO-2 was successfully launched on 2 July 2014 and has gathered more than 2 years of observations. The v7/v7r operational data products from September 2014 to January 2016 are discussed here. On monthly timescales, 7 to 12 % of these measurements are sufficiently cloud and aerosol free to yield estimates of the column-averaged atmospheric CO2 dry air mole fraction, XCO2, that pass all quality tests. During the first year of operations, the observing strategy, instrument calibration, and retrieval algorithm were optimized to improve both the data yield and the accuracy of the products. With these changes, global maps of XCO2 derived from the OCO-2 data are revealing some of the most robust features of the atmospheric carbon cycle. This includes XCO2 enhancements co-located with intense fossil fuel emissions in eastern US and eastern China, which are most obvious between October and December, when the north–south XCO2 gradient is small. Enhanced XCO2 coincident with biomass burning in the Amazon, central Africa, and Indonesia is also evident in this season. In May and June, when the north–south XCO2 gradient is largest, these sources are less apparent in global maps. During this part of the year, OCO-2 maps show a more than 10 ppm reduction in XCO2 across the Northern Hemisphere, as photosynthesis by the land biosphere rapidly absorbs CO2. As the carbon cycle science community continues to analyze these OCO-2 data, information on regional-scale sources (emitters) and sinks (absorbers) which impart XCO2 changes on the order of 1 ppm, as well as far more subtle features, will emerge from this high-resolution global dataset.
0
Paper
Citation262
0
Save
0

Methane retrieved from TROPOMI: improvement of the data product and validation of the first 2 years of measurements

Alba Lorente et al.Jan 28, 2021
Abstract. The TROPOspheric Monitoring Instrument (TROPOMI) on board the Sentinel 5 Precursor (S5-P) satellite provides methane (CH4) measurements with high accuracy and exceptional temporal and spatial resolution and sampling. TROPOMI CH4 measurements are highly valuable to constrain emissions inventories and for trend analysis, with strict requirements on the data quality. This study describes the improvements that we have implemented to retrieve CH4 from TROPOMI using the RemoTeC full-physics algorithm. The updated retrieval algorithm features a constant regularization scheme of the inversion that stabilizes the retrieval and yields less scatter in the data and includes a higher resolution surface altitude database. We have tested the impact of three state-of-the-art molecular spectroscopic databases (HITRAN 2008, HITRAN 2016 and Scientific Exploitation of Operational Missions – Improved Atmospheric Spectroscopy Databases SEOM-IAS) and found that SEOM-IAS provides the best fitting results. The most relevant update in the TROPOMI XCH4 data product is the implementation of an a posteriori correction fully independent of any reference data that is more accurate and corrects for the underestimation at low surface albedo scenes and the overestimation at high surface albedo scenes. After applying the correction, the albedo dependence is removed to a large extent in the TROPOMI versus satellite (Greenhouse gases Observing SATellite – GOSAT) and TROPOMI versus ground-based observations (Total Carbon Column Observing Network – TCCON) comparison, which is an independent verification of the correction scheme. We validate 2 years of TROPOMI CH4 data that show the good agreement of the updated TROPOMI CH4 with TCCON (−3.4 ± 5.6 ppb) and GOSAT (−10.3 ± 16.8 ppb) (mean bias and standard deviation). Low- and high-albedo scenes as well as snow-covered scenes are the most challenging for the CH4 retrieval algorithm, and although the a posteriori correction accounts for most of the bias, there is a need to further investigate the underlying cause.
0
Paper
Citation255
0
Save
0

Atmospheric carbon dioxide retrieved from the Greenhouse gases Observing SATellite (GOSAT): Comparison with ground‐based TCCON observations and GEOS‐Chem model calculations

A. Cogan et al.Oct 1, 2012
We retrieved column‐averaged dry air mole fractions of atmospheric carbon dioxide ( ) from backscattered short‐wave infrared (SWIR) sunlight measured by the Japanese Greenhouse gases Observing SATellite (GOSAT). Over two years of retrieved from GOSAT is compared with inferred from collocated SWIR measurements by seven ground‐based Total Carbon Column Observing Network (TCCON) stations. The average difference between GOSAT and TCCON for individual TCCON sites ranges from −0.87 ppm to 0.77 ppm with a mean value of 0.1 ppm and standard deviation of 0.56 ppm. We find an average bias between all GOSAT and TCCON retrievals of −0.20 ppm with a standard deviation of 2.26 ppm and a correlation coefficient of 0.75. One year of was retrieved from GOSAT globally, which was compared to global 3‐D GEOS‐Chem chemistry transport model calculations. We find that the latitudinal gradient, seasonal cycles, and spatial variability of GOSAT and GEOS‐Chem agree well in general with a correlation coefficient of 0.61. Regional differences between GEOS‐Chem model calculations and GOSAT observations are typically less than 1 ppm except for the Sahara and central Asia where a mean difference between 2 to 3 ppm is observed, indicating regional biases in the GOSAT retrievals unobserved by the current TCCON network. Using a bias correction scheme based on linear regression these regional biases are significantly reduced, approaching the required accuracy for surface flux inversions.
0
Paper
Citation213
0
Save