HY
Huanzhou Yu
Author with expertise in Magnetic Resonance Imaging Applications in Medicine
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
4
(100% Open Access)
Cited by:
1,553
h-index:
0
/
i10-index:
0
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise

Chia‐Ying Liu et al.Jul 24, 2007
Quantification of hepatic steatosis is a significant unmet need for the diagnosis and treatment of patients with nonalcoholic fatty liver disease (NAFLD). MRI is capable of separating water and fat signals in order to quantify fatty infiltration of the liver (hepatic steatosis). Unfortunately, fat signal has confounding T(1) effects and the nonzero mean noise in low signal-to-noise ratio (SNR) magnitude images can lead to incorrect estimation of the true lipid percentage. In this study, the effects of bias from T(1) effects and image noise were investigated. An oil/water phantom with volume fat-fractions ranging linearly from 0% to 100% was designed and validated using a spoiled gradient echo (SPGR) sequence in combination with a chemical-shift based fat-water separation method known as iterative decomposition of water and fat with echo asymmetry and least squares estimation (IDEAL). We demonstrated two approaches to reduce the effects of T(1): small flip angle (flip angle) and dual flip angle methods. Both methods were shown to effectively minimize deviation of the measured fat-fraction from its true value. We also demonstrated two methods to reduce noise bias: magnitude discrimination and phase-constrained reconstruction. Both methods were shown to reduce this noise bias effectively from 15% to less than 1%.
0

Multiecho reconstruction for simultaneous water‐fat decomposition and T2* estimation

Huanzhou Yu et al.Sep 25, 2007
Abstract Purpose To describe and demonstrate the feasibility of a novel multiecho reconstruction technique that achieves simultaneous water‐fat decomposition and T2* estimation. The method removes interference of water‐fat separation with iron‐induced T2* effects and therefore has potential for the simultaneous characterization of hepatic steatosis (fatty infiltration) and iron overload. Materials and Methods The algorithm called “T2*‐IDEAL” is based on the IDEAL water‐fat decomposition method. A novel “complex field map” construct is used to estimate both R2* (1/T2*) and local B 0 field inhomogeneities using an iterative least‐squares estimation method. Water and fat are then decomposed from source images that are corrected for both T2* and B 0 field inhomogeneity. Results It was found that a six‐echo multiecho acquisition using the shortest possible echo times achieves an excellent balance of short scan and reliable R2* measurement. Phantom experiments demonstrate the feasibility with high accuracy in R2* measurement. Promising preliminary in vivo results are also shown. Conclusion The T2*‐IDEAL technique has potential applications in imaging of diffuse liver disease for evaluation of both hepatic steatosis and iron overload in a single breath‐hold. J. Magn. Reson. Imaging 2007;26:1153–1161. © 2007 Wiley‐Liss, Inc.
0
Citation405
0
Save
0

Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy

Sina Meisamy et al.Jan 20, 2011
Purpose To prospectively compare an investigational version of a complex-based chemical shift–based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. Materials and Methods This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24–71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2* correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r2), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2* correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Results Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2* correction, spectral modeling of fat, and magnitude fitting for eddy current correction were used (r2 = 0.99; slope ± standard deviation = 1.00 ± 0.01, P = .77; intercept ± standard deviation = 0.2% ± 0.1, P = .19). Conclusion T1-independent chemical shift–based water-fat separation MR imaging methods can accurately quantify fat over the entire liver, by using MR spectroscopy as the reference standard, when T2* correction, spectral modeling of fat, and eddy current correction methods are used. © RSNA, 2011
0

Water–fat separation with IDEAL gradient‐echo imaging

Scott Reeder et al.Feb 26, 2007
Abstract Purpose To combine gradient‐echo (GRE) imaging with a multipoint water–fat separation method known as “iterative decomposition of water and fat with echo asymmetry and least squares estimation” (IDEAL) for uniform water–fat separation. Robust fat suppression is necessary for many GRE imaging applications; unfortunately, uniform fat suppression is challenging in the presence of B 0 inhomogeneities. These challenges are addressed with the IDEAL technique. Materials and Methods Echo shifts for three‐point IDEAL were chosen to optimize noise performance of the water–fat estimation, which is dependent on the relative proportion of water and fat within a voxel. Phantom experiments were performed to validate theoretical SNR predictions. Theoretical echo combinations that maximize noise performance are discussed, and examples of clinical applications at 1.5T and 3.0T are shown. Results The measured SNR performance validated theoretical predictions and demonstrated improved image quality compared to unoptimized echo combinations. Clinical examples of the liver, breast, heart, knee, and ankle are shown, including the combination of IDEAL with parallel imaging. Excellent water–fat separation was achieved in all cases. The utility of recombining water and fat images into “in‐phase,” “out‐of‐phase,” and “fat signal fraction” images is also discussed. Conclusion IDEAL‐SPGR provides robust water–fat separation with optimized SNR performance at both 1.5T and 3.0T with multicoil acquisitions and parallel imaging in multiple regions of the body. J. Magn. Reson. Imaging 2007;25:644–652. © 2007 Wiley‐Liss, Inc.
0
Citation329
0
Save