FN
Fabian Nietlispach
Author with expertise in Management of Valvular Heart Disease
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
12
(83% Open Access)
Cited by:
3,187
h-index:
53
/
i10-index:
150
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Acute kidney injury following transcatheter aortic valve implantation: predictive factors, prognostic value, and comparison with surgical aortic valve replacement

Rodrigo Bagur et al.Dec 27, 2009
Very few data exist on the occurrence of acute kidney injury (AKI) associated with transcatheter aortic valve implantation (TAVI). The objectives of the present study were (i) to determine the incidence, predictive factors, and prognostic value of AKI following TAVI, and (ii) to compare the occurrence of AKI in TAVI vs. surgical aortic valve replacement (SAVR) in patients with pre-procedural chronic kidney disease (CKD). A total of 213 patients (mean age 82 ± 8 years) undergoing TAVI for the treatment of severe aortic stenosis were included in the study. Acute kidney injury was defined as a reduction of >25% in estimated glomerular filtration rate (eGFR) within 48 h following the procedure or the need for haemodialysis during index hospitalization. Those patients with pre-procedural CKD (eGFR <60 mL/min/1.73 m2, n = 119) were compared with 104 contemporary patients with CKD who underwent isolated SAVR. The incidence of AKI following TAVI was 11.7%, with 1.4% of the patients requiring haemodialysis. Predictive factors of AKI were hypertension (OR: 4.66; 95% CI: 1.04–20.87), chronic obstructive pulmonary disease (OR: 2.64, 95% CI: 1.10–6.36), and peri-operative blood transfusion (OR: 3.47, 95% CI: 1.30–9.29). Twenty-one patients (9.8%) died during index hospitalization, and the logistic EuroSCORE (OR: 1.03 for each increase of 1%; 95% CI: 1.01–1.06) and occurrence of AKI (OR: 4.14, 95% CI: 1.42–12.13) were identified as independent predictors of postoperative mortality. Patients with CKD who underwent TAVI were older, had a higher logistic EuroSCORE and lower pre-procedural eGFR values compared with those who underwent SAVR (P < 0.0001 for all). The incidence of AKI was lower (P = 0.001; P = 0.014 after propensity score adjustment) in CKD patients who underwent TAVI (9.2%, need for haemodialysis: 2.5%) compared with those who underwent SAVR (25.9%, need for haemodialysis: 8.7%). Acute kidney injury occurred in 11.7% of the patients following TAVI and was associated with a greater than four-fold increase in the risk of postoperative mortality. Hypertension, chronic obstructive pulmonary disease, and blood transfusion were predictive factors of AKI. In those patients with pre-procedural CKD, TAVI was associated with a significant reduction of AKI compared with SAVR.
0

Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis

Sung-Han Yoon et al.Mar 18, 2017
Transcatheter aortic valve replacement (TAVR) is being increasingly performed in patients with bicuspid aortic valve stenosis (AS). This study sought to compare the procedural and clinical outcomes in patients with bicuspid versus tricuspid AS from the Bicuspid AS TAVR multicenter registry. Outcomes of 561 patients with bicuspid AS and 4,546 patients with tricuspid AS were compared after propensity score matching, assembling 546 pairs of patients with similar baseline characteristics. Procedural and clinical outcomes were recorded according to Valve Academic Research Consortium-2 criteria. Compared with patients with tricuspid AS, patients with bicuspid AS had more frequent conversion to surgery (2.0% vs. 0.2%; p = 0.006) and a significantly lower device success rate (85.3% vs. 91.4%; p = 0.002). Early-generation devices were implanted in 320 patients with bicuspid and 321 patients with tricuspid AS, whereas new-generation devices were implanted in 226 and 225 patients with bicuspid and tricuspid AS, respectively. Within the group receiving early-generation devices, bicuspid AS had more frequent aortic root injury (4.5% vs. 0.0%; p = 0.015) when receiving the balloon-expanding device, and moderate-to-severe paravalvular leak (19.4% vs. 10.5%; p = 0.02) when receiving the self-expanding device. Among patients with new-generation devices, however, procedural results were comparable across different prostheses. The cumulative all-cause mortality rates at 2 years were comparable between bicuspid and tricuspid AS (17.2% vs. 19.4%; p = 0.28). Compared with tricuspid AS, TAVR in bicuspid AS was associated with a similar prognosis, but lower device success rate. Procedural differences were observed in patients treated with the early-generation devices, whereas no differences were observed with the new-generation devices.
0

Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry

Henrique Ribeiro et al.Jul 19, 2017
There are limited data on coronary obstruction following transcatheter valve-in-valve (ViV) implantation inside failed aortic bioprostheses. The objectives of this study were to determine the incidence, predictors, and clinical outcomes of coronary obstruction in transcatheter ViV procedures. A total of 1612 aortic procedures from the Valve-in-Valve International Data (VIVID) Registry were evaluated. Data were subject to centralized blinded corelab computed tomography (CT) analysis in a subset of patients. The virtual transcatheter valve to coronary ostium distance (VTC) was determined. A total of 37 patients (2.3%) had clinically evident coronary obstruction. Baseline clinical characteristics in the coronary obstruction patients were similar to controls. Coronary obstruction was more common in stented bioprostheses with externally mounted leaflets or stentless bioprostheses than in stented with internally mounted leaflets bioprostheses (6.1% vs. 3.7% vs. 0.8%, respectively; P < 0.001). CT measurements were obtained in 20 (54%) and 90 (5.4%) of patients with and without coronary obstruction, respectively. VTC distance was shorter in coronary obstruction patients in relation to controls (3.24 ± 2.22 vs. 6.30 ± 2.34, respectively; P < 0.001). Using multivariable analysis, the use of a stentless or stented bioprosthesis with externally mounted leaflets [odds ratio (OR): 7.67; 95% confidence interval (CI): 3.14–18.7; P < 0.001] associated with coronary obstruction for the global population. In a second model with CT data, a shorter VTC distance predicted this complication (OR: 0.22 per 1 mm increase; 95% CI: 0.09–0.51; P < 0.001), with an optimal cut-off level of 4 mm (area under the curve: 0.943; P < 0.001). Coronary obstruction was associated with a high 30-day mortality (52.9% vs. 3.9% in the controls, respectively; P < 0.001). Coronary obstruction following aortic ViV procedures is a life-threatening complication that occurred more frequently in patients with prior stentless or stented bioprostheses with externally mounted leaflets and in those with a short VTC.
0

Association Between Transcatheter Aortic Valve Replacement and Subsequent Infective Endocarditis and In-Hospital Death

Ander Regueiro et al.Sep 13, 2016

Importance

 Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). 

Objective

 To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. 

Design, Setting, and Participants

 The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. 

Exposure

 Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. 

Main Outcomes and Measures

 Infective endocarditis and in-hospital mortality after infective endocarditis. 

Results

 A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care–associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients.Enterococcispecies andStaphylococcus aureuswere the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). 

Conclusions and Relevance

 Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality.
0

Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis

Sung-Han Yoon et al.Sep 1, 2016
Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data exist comparing the results of TAVR with new-generation devices versus early-generation devices. This study sought to evaluate the clinical outcomes of TAVR for bicuspid AS with early- and new-generation devices. The Bicuspid TAVR Registry is an international multicenter study enrolling consecutive patients with bicuspid AS undergoing TAVR between April 2005 and May 2015. Of 301 patients, 199 patients (71.1%) were treated with early-generation devices (Sapien XT [Edwards Lifesciences Corporation, Irvine, California]: n = 87; CoreValve [Medtronic, Minneapolis, Minnesota]: n = 112) and 102 with new-generation devices (Sapien 3 [Edwards Lifesciences Corporation]: n = 91; Lotus [Boston Scientific Corporation, Marlborough, Massachusetts]: n = 11). The mean Society of Thoracic Surgeons score was 4.7 ± 5.2 without significant differences between groups (4.6 ± 5.1 vs. 4.9 ± 5.4; p = 0.57). Overall, all-cause mortality rates were 4.3% at 30 days and 14.4% at 1 year. Moderate or severe paravalvular leak was absent and significantly less frequent with new-generation compared to early-generation devices (0.0% vs. 8.5%; p = 0.002), which resulted in a higher device success rate (92.2% vs. 80.9%; p = 0.01). There were no differences between early- and new-generation devices in stroke (2.5% vs. 2.0%; p > 0.99), life-threatening bleeding (3.5% vs. 2.9%; p > 0.99), major vascular complication (4.5% vs. 2.9%; p = 0.76), stage 2 to 3 acute kidney injury (2.5% vs. 2.9%; p > 0.99), early safety endpoints (15.1% vs. 10.8%; p = 0.30), and 30-day all-cause mortality (4.5% vs. 3.9%; p > 0.99). The clinical outcomes of TAVR in patients with bicuspid AS were favorable. New-generation devices were associated with less paravalvular leak and, hence, a higher device success rate than early-generation devices. (The Bicuspid Aortic Stenosis Following Transcatheter Aortic Valve Replacement Registry [Bicuspid TAVR]; NCT02394184)
Load More