SK
S. Kazama
Author with expertise in Particle Physics and High-Energy Collider Experiments
Achievements
Cited Author
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
6
(83% Open Access)
Cited by:
1,576
h-index:
85
/
i10-index:
266
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

Excess electronic recoil events in XENON1T

E. Aprile et al.Oct 12, 2020
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 tonne-years and an unprecedentedly low background rate of 76±2stat events/(tonne×year×keV) between 1 and 30 keV, the data enable one of the most sensitive searches for solar axions, an enhanced neutrino magnetic moment using solar neutrinos, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4σ significance, and a three-dimensional 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by gae<3.8×10−12, gaegeffan<4.8×10−18, and gaegaγ<7.7×10−22 GeV−1, and excludes either gae=0 or gaegaγ=gaegeffan=0. The neutrino magnetic moment signal is similarly favored over background at 3.2σ, and a confidence interval of μν∈(1.4,2.9)×10−11 μB (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by β decays of tritium at 3.2σ significance with a corresponding tritium concentration in xenon of (6.2±2.0)×10−25 mol/mol. Such a trace amount can neither be confirmed nor excluded with current knowledge of its production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are decreased to 2.0σ and 0.9σ, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at (2.3±0.2) keV (68% C.L.) with a 3.0σ global (4.0σ local) significance over background. This analysis sets the most restrictive direct constraints to date on pseudoscalar and vector bosonic dark matter for most masses between 1 and 210 keV/c2. We also consider the possibility that 37Ar may be present in the detector, yielding a 2.82 keV peak from electron capture. Contrary to tritium, the 37Ar concentration can be tightly constrained and is found to be negligible.8 MoreReceived 30 June 2020Accepted 16 September 2020DOI:https://doi.org/10.1103/PhysRevD.102.072004Published by the American Physical Society under the terms of the Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. Funded by SCOAP3.Published by the American Physical SocietyPhysics Subject Headings (PhySH)Research AreasAxionsBeta decayMagnetic momentParticle astrophysicsParticle dark matterSolar neutrinosTechniquesDark matter detectorsMulti-purpose particle detectorsParticles & FieldsNuclear Physics
0

Light Dark Matter Search with Ionization Signals in XENON1T

E. Aprile et al.Dec 17, 2019
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of (22±3) tonne day. Above ∼0.4 keVee, we observe <1 event/(tonne day keVee), which is more than 1000 times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses mχ within 3–6 GeV/c2, DM-electron scattering for mχ>30 MeV/c2, and absorption of dark photons and axionlike particles for mχ within 0.186–1 keV/c2.Received 29 July 2019Revised 7 November 2019DOI:https://doi.org/10.1103/PhysRevLett.123.251801Published by the American Physical Society under the terms of the Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. Funded by SCOAP3.Published by the American Physical SocietyPhysics Subject Headings (PhySH)Research AreasDark matterParticle dark matterPhysical SystemsWeakly interacting massive particlesTechniquesDark matter detectorsTime-projection chambersGravitation, Cosmology & AstrophysicsParticles & Fields
0

Projected WIMP sensitivity of the XENONnT dark matter experiment

E. Aprile et al.Nov 1, 2020
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to $12.3 \pm 0.6$ (keV t y)$^{-1}$ and $(2.2\pm 0.5)\times 10^{-3}$ (keV t y)$^{-1}$, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage. With the exposure goal of 20 t$\,$y, the expected sensitivity to spin-independent WIMP-nucleon interactions reaches a cross-section of $1.4\times10^{-48}$ cm$^2$ for a 50 GeV/c$^2$ mass WIMP at 90% confidence level, more than one order of magnitude beyond the current best limit, set by XENON1T. In addition, we show that for a 50 GeV/c$^2$ WIMP with cross-sections above $2.6\times10^{-48}$ cm$^2$ ($5.0\times10^{-48}$ cm$^2$) the median XENONnT discovery significance exceeds 3$\sigma$ (5$\sigma$). The expected sensitivity to the spin-dependent WIMP coupling to neutrons (protons) reaches $2.2\times10^{-43}$ cm$^2$ ($6.0\times10^{-42}$ cm$^2$).
0

Abstract 4141028: Predicting survival after percutaneous ventricular assist device for patients with cardiogenic shock: J-PVAD risk score

Toru Kondo et al.Nov 12, 2024
Background: Cardiogenic shock (CS) is a lethal condition and mechanical circulatory support is indicated if refractory to drug treatment. A recent report showed using Impella with standard care led to a lower risk of death in patients with acute myocardial infarction and CS. This finding may increase the clinical use of Impella, but prognostic models for patients after Impella are lacking. Aims: To identify factors that predict in-hospital mortality in CS requiring Impella and to develop a new prognostic model. Methods: We used the dataset of the Japanese registry for Percutaneous Ventricular Assist Device (J-PVAD), which included all the cases treated with Impella in Japan. Two-thirds of the patients treated with Impella due to CS were randomly assigned to a derivation cohort, and the other third was reserved as a validation cohort. Using the derivation cohort, a backward stepwise logistic regression model was built to identify the factor associated with in-hospital mortality. Results: Of the total 1,715 patients in the derivation cohort, 989 patients were discharged alive and 726 patients (42.3%) died during hospitalization. From 28 variables available in the J-PVAD registry, 12 variables were independently associated with in-hospital mortality and applied for a component of the risk model; age, sex, body mass index, etiology of fulminant myocarditis, cardiac arrest in hospital, extracorporeal membrane oxygenation use, mean arterial pressure, lactate level, lactate dehydrogenase level, total bilirubin level, creatinine level, and albumin level (Table 1). The J-PVAD risk score was created by assigning scores to these components based on the coefficients (Table 1). An Example of predicted in-hospital mortality according to the J-PVAD risk score is shown in Table 2. The area under the receiver operating characteristics curve (AUC) of the J-PVAD risk score was 0.76 (95% confidence interval [CI] 0.73–0.78). The comparison of predicted and observed in-hospital mortality according to the 7th quantiles by the J-PVAD risk score showed good calibration (Figure A). In the validation cohort (n=726), the J-PVAD risk score showed good discrimination ability (AUC 0.77 [95%CI 0.74–0.81]) and calibration (Figure B). Conclusions: The J-PVAD risk score can be calculated using variables easily obtained in routine clinical practice. It helps the accurate stratification of the risk for mortality and facilitates clinical decision-making.