AB
Allison Beck
Author with expertise in Influenza Virus Research and Epidemiology
Achievements
Open Access Advocate
Cited Author
Key Stats
Upvotes received:
0
Publications:
2
(100% Open Access)
Cited by:
610
h-index:
12
/
i10-index:
14
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

The safety, immunogenicity, and acceptability of inactivated influenza vaccine delivered by microneedle patch (TIV-MNP 2015): a randomised, partly blinded, placebo-controlled, phase 1 trial

Nadine Rouphael et al.Jun 27, 2017
Microneedle patches provide an alternative to conventional needle-and-syringe immunisation, and potentially offer improved immunogenicity, simplicity, cost-effectiveness, acceptability, and safety. We describe safety, immunogenicity, and acceptability of the first-in-man study on single, dissolvable microneedle patch vaccination against influenza.The TIV-MNP 2015 study was a randomised, partly blinded, placebo-controlled, phase 1, clinical trial at Emory University that enrolled non-pregnant, immunocompetent adults from Atlanta, GA, USA, who were aged 18-49 years, naive to the 2014-15 influenza vaccine, and did not have any significant dermatological disorders. Participants were randomly assigned (1:1:1:1) to four groups and received a single dose of inactivated influenza vaccine (fluvirin: 18 μg of haemagglutinin per H1N1 vaccine strain, 17 μg of haemagglutinin per H3N2 vaccine strain, and 15 μg of haemagglutinin per B vaccine strain) (1) by microneedle patch or (2) by intramuscular injection, or received (3) placebo by microneedle patch, all administered by an unmasked health-care worker; or received a single dose of (4) inactivated influenza vaccine by microneedle patch self-administered by study participants. A research pharmacist prepared the randomisation code using a computer-generated randomisation schedule with a block size of 4. Because of the nature of the study, participants were not masked to the type of vaccination method (ie, microneedle patch vs intramuscular injection). Primary safety outcome measures are the incidence of study product-related serious adverse events within 180 days, grade 3 solicited or unsolicited adverse events within 28 days, and solicited injection site and systemic reactogenicity on the day of study product administration through 7 days after administration, and secondary safety outcomes are new-onset chronic illnesses within 180 days and unsolicited adverse events within 28 days, all analysed by intention to treat. Secondary immunogenicity outcomes are antibody titres at day 28 and percentages of seroconversion and seroprotection, all determined by haemagglutination inhibition antibody assay. The trial is completed and registered with ClinicalTrials.gov, number NCT02438423.Between June 23, 2015, and Sept 25, 2015, 100 participants were enrolled and randomly assigned to a group. There were no treatment-related serious adverse events, no treatment-related unsolicited grade 3 or higher adverse events, and no new-onset chronic illnesses. Among vaccinated groups (vaccine via health-care worker administered microneedle patch or intramuscular injection, or self-administered microneedle patch), overall incidence of solicited adverse events (n=89 vs n=73 vs n=73) and unsolicited adverse events (n=18 vs n=12 vs n=14) were similar. Reactogenicity was mild, transient, and most commonly reported as tenderness (15 [60%] of 25 participants [95% CI 39-79]) and pain (11 [44%] of 25 [24-65]) after intramuscular injection; and as tenderness (33 [66%] of 50 [51-79]), erythema (20 [40%] of 50 [26-55]), and pruritus (41 [82%] of 50 [69-91]) after vaccination by microneedle patch application. The geometric mean titres were similar at day 28 between the microneedle patch administered by a health-care worker versus the intramuscular route for the H1N1 strain (1197 [95% CI 855-1675] vs 997 [703-1415]; p=0·5), the H3N2 strain (287 [192-430] vs 223 [160-312]; p=0·4), and the B strain (126 [86-184] vs 94 [73-122]; p=0·06). Similar geometric mean titres were reported in participants who self-administered the microneedle patch (all p>0·05). The seroconversion percentages were significantly higher at day 28 after microneedle patch vaccination compared with placebo (all p<0·0001) and were similar to intramuscular injection (all p>0·01).Use of dissolvable microneedle patches for influenza vaccination was well tolerated and generated robust antibody responses.National Institutes of Health.
0

Safety, tolerability, and immunogenicity of two Zika virus DNA vaccine candidates in healthy adults: randomised, open-label, phase 1 clinical trials

Martin Gaudinski et al.Dec 5, 2017
The Zika virus epidemic and associated congenital infections have prompted rapid vaccine development. We assessed two new DNA vaccines expressing premembrane and envelope Zika virus structural proteins.We did two phase 1, randomised, open-label trials involving healthy adult volunteers. The VRC 319 trial, done in three centres, assessed plasmid VRC5288 (Zika virus and Japanese encephalitis virus chimera), and the VRC 320, done in one centre, assessed plasmid VRC5283 (wild-type Zika virus). Eligible participants were aged 18-35 years in VRC19 and 18-50 years in VRC 320. Participants were randomly assigned 1:1 by a computer-generated randomisation schedule prepared by the study statistician. All participants received intramuscular injection of 4 mg vaccine. In VRC 319 participants were assigned to receive vaccinations via needle and syringe at 0 and 8 weeks, 0 and 12 weeks, 0, 4, and 8 weeks, or 0, 4, and 20 weeks. In VRC 320 participants were assigned to receive vaccinations at 0, 4, and 8 weeks via single-dose needle and syringe injection in one deltoid or split-dose needle and syringe or needle-free injection with the Stratis device (Pharmajet, Golden, CO, USA) in each deltoid. Both trials followed up volunteers for 24 months for the primary endpoint of safety, assessed as local and systemic reactogenicity in the 7 days after each vaccination and all adverse events in the 28 days after each vaccination. The secondary endpoint in both trials was immunogenicity 4 weeks after last vaccination. These trials are registered with ClinicalTrials.gov, numbers NCT02840487 and NCT02996461.VRC 319 enrolled 80 participants (20 in each group), and VRC 320 enrolled 45 participants (15 in each group). One participant in VRC 319 and two in VRC 320 withdrew after one dose of vaccine, but were included in the safety analyses. Both vaccines were safe and well tolerated. All local and systemic symptoms were mild to moderate. In both studies, pain and tenderness at the injection site was the most frequent local symptoms (37 [46%] of 80 participants in VRC 319 and 36 [80%] of 45 in VRC 320) and malaise and headache were the most frequent systemic symptoms (22 [27%] and 18 [22%], respectively, in VRC 319 and 17 [38%] and 15 [33%], respectively, in VRC 320). For VRC5283, 14 of 14 (100%) participants who received split-dose vaccinations by needle-free injection had detectable positive antibody responses, and the geometric mean titre of 304 was the highest across all groups in both trials.VRC5283 was well tolerated and has advanced to phase 2 efficacy testing.Intramural Research Program of the Vaccine Research Center, National Institute of Allergy and Infectious Diseases, National Institutes of Health.
0
Citation268
0
Save