LS
Leonid Shmuylovich
Author with expertise in Maternal Morbidity Associated with Pregnancy and Childbirth
Achievements
Open Access Advocate
Key Stats
Upvotes received:
0
Publications:
4
(75% Open Access)
Cited by:
0
h-index:
13
/
i10-index:
13
Reputation
Biology
< 1%
Chemistry
< 1%
Economics
< 1%
Show more
How is this calculated?
Publications
0

727 Leveraging the naturally occurring spotted pigmentation of Hampshire swine to assess the impact of skin pigmentation on light-based medical devices

Mitchell Pet et al.Aug 1, 2024
+7
A
A
M
5

Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage

Francesca Bonetta-Misteli et al.Feb 21, 2023
+3
T
T
F
Abstract Postpartum hemorrhage (PPH) is both the leading and most preventable cause of maternal mortality. PPH is currently diagnosed through visual estimation of blood loss or vital sign analysis of shock index (ratio of heart rate to systolic blood pressure). Visual assessment underestimates blood loss, particularly in the setting of internal bleeding, and compensatory mechanisms stabilize hemodynamics until hemorrhage is massive, beyond the point of pharmaceutical intervention. Quantitative monitoring of hemorrhage-induced compensatory processes, such as the constriction of peripheral vessels to shunt blood to the central organs, may provide an early alert for PPH. To this end, we developed a low-cost, wearable optical device that continuously monitors peripheral perfusion via laser speckle flow index (LSFI) to detect hemorrhage-induced peripheral vasoconstriction. The device was first tested using flow phantoms across a range of physiologically relevant flow rates and demonstrated a linear response. Subsequent testing occurred in swine hemorrhage studies (n=6) by placing the device on the posterior side of the swine’s front hock and withdrawing blood from the femoral vein at a constant rate. Resuscitation with intravenous crystalloids followed the induced hemorrhage. The mean LSFI vs. percent estimated blood volume loss had an average correlation coefficient of −0.95 during the hemorrhage phase and 0.79 during resuscitation, both of which were superior to the performance of the shock index. With continued development, this noninvasive, low-cost, and reusable device has global potential to provide an early alert of PPH when low-cost and accessible management strategies are most effective, helping to reduce maternal morbidity and mortality from this largely preventable problem.
0

Skin Pigmentation Affects ViOptix T.Ox Performance in Variably Pigmented Preclinical Model of Flap Ischemia and Congestion

Amanda Westman et al.Jun 1, 2024
+2
M
J
A
Background: Free flap monitoring is more difficult in patients with dark skin because ischemia and congestion can be masked by pigmentation. For this reason, adjunct methods such as cutaneous near-infrared spectroscopy are of elevated importance in patients with highly pigmented skin. The purpose of this experiment is to determine if ViOpitx T.Ox performance is affected by cutaneous pigmentation. Methods: Swine with naturally occurring areas of nonpigmented and pigmented skin were used. Pigmentation of each animal was assessed using spectrophotometry and histopathology. During normoxemia, tissue oxygenation (StO 2 ) measurements were taken of nonpigmented and pigmented skin using the T.Ox device. A bicolor pedicled rectus abdominis myocutaneous flap was raised, and T.Ox probe was adhered to adjacent areas of opposite coloration on the same flap. StO 2 was measured continuously during reversible episodes of flap ischemia and congestion (n = 4 swine, n = 6 flaps). Results: There was not a significant difference between baseline StO 2 values of nonpigmented (49% ± 7.9%) and pigmented skin (47% ± 6.2%). The absolute change in StO 2 was significantly larger during both ischemia (6%) and congestion (16%) in nonpigmented skin compared with adjacent pigmented skin. Conclusions: T.Ox detects flap ischemia and congestion in both highly pigmented and nonpigmented skin. However, surgeons need to be aware that StO 2 changes related to complete flap ischemia or congestion may be much more subtle than what is seen in nonpigmented skin. This study establishes a novel internally controlled porcine model that isolates the impact of skin pigmentation when assessing cutaneous devices measuring tissue oxygenation.